安瑞科(蚌埠) · CIMC Enric · Anhui
Gas compression supported by a Bengbu manufacturing and inspection base
Enric (Bengbu) describes itself as a wholly owned CIMC Enric subsidiary established in 2002, with compressor-manufacturing heritage reaching back to the 1950s.
Its published facilities cover machining, welding, heat treatment, pretreatment and assembly, with metrology, physical testing, nondestructive inspection and compressor testing. Connect those processes to the actual order's material, weld, measurement and assembly-test records.

A defined standards-development record
The national standards platform lists Enric (Bengbu) among the drafting organizations for JB/T 10909-2026, Small reciprocating piston hydrogen compressors, implemented on 1 September 2026. Drafting participation is distinct from the selected equipment's test documents or destination approval.
Modular CNG filling station
Four modules, four different responsibilities

- 01
Compression
Compressor, explosion-protected motor, cooling, safety valves, gas piping, lubrication, drains, instruments and controls.
300–6,700 Nm³/h is the published family discharge-volume range. Ask for one selected model's suction, delivery, driver and normal-volume reference conditions.
- 02
Pretreatment
Filtration, pressure stabilization, metering and drying; the listed equipment includes an emergency shutoff valve, pipeline filter, flow meter, buffer vessel and dryer.
Agree inlet gas quality, outlet moisture, pressure loss and regeneration/consumable scope.
- 03
Storage
A priority panel and cascade cylinders form the storage module.
Size storage for the actual users and filling schedule. Identify vessels, working limits, safety/control responsibilities and applicable destination documents.
- 04
Dispensing or filling
The described interfaces include dispenser, time-fill and discharge-pole arrangements.
Agree connectors, metering and users. Compressor normal volume, dispenser volume and mass per minute need an agreed gas/reference basis before comparison.
Wellhead → processing, transport or network
A booster selection starts at the suction boundary
Enric describes compressor packages with electric-motor or gas-engine drive, piping, cooling, controls and electrical equipment. Cooling can be air, water or mixed.
- Separate maximum volume
- 200,000 Nm³/day
- Separate maximum discharge pressure
- 10.0 MPa
These are separate family endpoints. They are not a simultaneous rating for one machine.
Request a selected performance sheet at minimum, normal and maximum suction conditions, including required delivery pressure and defined normal-volume conditions.
Gathering and booster package details →
Give engineering the operating envelope
- Gas
- Composition, condensate, contaminants and corrosive components for review.
- Inlet and outlet
- Suction temperature/pressure variations, delivery pressure, flow, turndown and hours.
- Site
- Ambient extremes, cooling utilities, electric supply or engine fuel, and hazardous-area requirements.
Specific historical development · August 2023
Keep the Bengbu diaphragm unit distinct from other group equipment
The parent group's release attributes a 45 MPa diaphragm hydrogen compressor to Bengbu, with 500 Nm³/h per head and 1,000 Nm³/h for two heads. The same release's liquid-drive unit was developed by the Shanghai business.
This development record does not define the duty of the natural-gas packages above. A hydrogen enquiry needs its own inlet/delivery envelope, gas quality, containment, cooling, safety and selected-model documentation.
Turn a gas duty into a comparable delivery scope

Before comparing offers
- Selected performance sheet tied to gas analysis and operating envelope.
- Process flow/P&ID, equipment list and module responsibility matrix.
- Protection and control cause-and-effect, selected driver and cooling utilities.
- Applicable material, pressure, electrical and hazardous-area documents.
- Shop/site acceptance, manuals and model/serial inspection records.
Commissioning, monitoring and support
Enric describes installation/commissioning guidance, training, technical documents and fault analysis, plus PLC-connected remote monitoring. Agree connected hardware, signals, alarms, access permissions and connectivity. Specify maintenance, critical spares, commissioning and destination support in the actual contract.
Send the gas analysis and system boundary
Define CNG filling or gathering/boosting, then attach inlet and delivery conditions, driver, cooling and required module scope.
Enric gas-package selection questions
Does 200,000 Nm³/day apply at 10.0 MPa?
The source states two separate maxima. Obtain the actual model's performance at your suction and delivery conditions; the two family endpoints are not a paired rating.
Is a compressor quotation a complete CNG station?
Define compression, pretreatment, storage and dispensing separately. Request an equipment list and responsibility matrix including gas treatment, controls, vessels and filling interfaces.
Can dispenser flow be compared directly with compressor Nm³/h?
Agree gas composition, reference conditions and operating points first. Dispenser volume, mass flow and compressor normal volume describe different quantities; storage and the filling schedule also matter.
Does standards drafting prove certification of the quoted unit?