0.8 MPa
1.05 m³/min
Guangzhou Panyu
Pair standard-pressure duties, or specify the medium-pressure compressor, receiver and dryer as a complete system.

GUANGZHOU GUANGWO · SHILOU, PANYU
广州广涡压缩机有限公司 presents scroll-airend development and manufacture and complete compressor packages from its Guangzhou Panyu location. Its company page names Guangwo and Jingba brands. Its catalogue separates standard-pressure, 1.6–3.0 MPa medium-pressure, oil-free, booster, airend and consumable selections.
The two existing products detailed here have an explicit lubricant grade and oil charge in their model tables. Choose their actual pressure point and supply boundary; the separate oil-free category does not change their lubrication mechanism.
The national standards platform names Guangzhou Guangwo among the drafting organizations for JB/T 11423-2013, general-use oil-injected scroll air compressors, displayed as current. This is a technical participation record, rather than an oil-free certificate or automatic compliance evidence for every current model.
GW-10D · LUBRICATED SCROLL

The table describes air cooling, integrated drive and 5 L dedicated scroll-compressor oil. This is a lubricated machine. The two rows below belong to different operating pressures.
1.05 m³/min
0.95 m³/min
Obtain the full flow test/reference conditions. Do not use the first point’s capacity as a guarantee at 1.0 MPa or infer package input from the model designation.
The source’s main-motor power cell contains 7.5 and an unexplained additional 6 together under kW. Obtain a clarified nameplate/electrical schedule, starter and protection details. A made-up single rating would be a poor basis for cables, breaker sizing or energy comparison.
State the sustained/peak use and acceptable pressure variation. Agree external receiver, dryer, filters and drains and the required oil/moisture/particle quality at the sampling point. Manufacturer residual-oil and noise figures without full test conditions are not universal process-air or room-noise guarantees.
GW-10D paired duties and installation information →GW-15DHY16 · MEDIUM-PRESSURE PACKAGE
The source pairs 1.0 m³/min with 1.6 MPa and lists a 420 L receiver. The original image shows the compressor, receiver and refrigerated-dryer section. Its readable cabinet marking is GW-15DHY; the 16 designation comes from the official model page/table.
It lists 4.5 L lubricant. A low residual-oil statement does not convert the scroll airend into an oil-free mechanism. Agree actual filter, dryer, condensate and air-quality scope for laser cutting or another sensitive process.

| Component | Published fact | Put into the order |
|---|---|---|
| Scroll compressor | 1.0 m³/min at 1.6 MPa 4.5 L lubricant | Flow reference, duty curve, oil-service and electrical schedule |
| Receiver | 420 L | Design/working pressure, safety valve, inspection and destination vessel documents |
| Refrigerated dryer | Separate section pictured and tabulated | Rating at 1.6 MPa, actual inlet temperature/flow, pressure dew point, drains and filters |
The main-motor cell prints 11 plus an unexplained 6 under kW. The dryer cell prints 0.74 under a W heading, alongside 220 V and 4.2 A. Request current component nameplates and an electrical schedule; these figures are not silently converted into a confirmed package rating.
Its own page lists 2.0 m³/min at 1.6 MPa, 1000 × 640 × 1110 mm, 360 kg, Rc3/4 and 8 L lubricant. It does not specify the 420 L receiver/dryer assembly of GW-15DHY16. Compare the complete supply boundary instead of assuming identical packages with double output.
SITE PREPARATION · DOCUMENTS · SERVICE
Use pressure at the machine after losses, demand peaks and the actual flow reference. Agree heat rejection, inlet/ambient conditions, service access and cabinet clearances.
Confirm main and auxiliary loads, starter, protection and drawings. A listed 380/50/3 supply does not establish compatibility with another frequency. Use actual outlet and receiver connection drawings.
Define oil, moisture and particle limits, treatment/drain scope and sampling tests. The manufacturer's application list is not a process-specific purity approval.
The support area lists separate standard- and medium-pressure instruction manuals, principle drawings, application guidance and electrical manuals. The visible instruction-manual listing dates are from 2021; obtain the current revision and exact offered-model coverage.
Include oil grade and replacement intervals, oil/filter and scroll-service parts, dryer and receiver maintenance, commissioning tests and actual warranty/destination support. The compressor, vessel and dryer have distinct inspection and ownership needs.
The model tables explicitly list lubricant and oil charges. Specify actual treatment and air-quality acceptance; the separate oil-free catalogue heading is not evidence about these lubricated models.
Provide the process cycle, permissible pressure swing, peak demand and actual compressor delivery. Receiver volume alone does not establish stable or uninterrupted supply.
Obtain the current main and auxiliary nameplates, electrical schedule, starter and protection requirements. The source cells contain unresolved power entries and cannot establish a reliable electrical design.
Send the pressure-flow point, demand cycle, receiver/dryer scope, air-quality target, ambient conditions and electrical supply.
Prepare a Guangwo enquiryInformation reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
Guangwo: Pair standard-pressure duties, or specify the medium-pressure compressor, receiver and dryer as a complete system.
Open RFQ