Guangzhou Panyu

Guangwo Guangzhou: lubricated scroll and package selection

Pair standard-pressure duties, or specify the medium-pressure compressor, receiver and dryer as a complete system.

GUANGZHOU GUANGWO · SHILOU, PANYU

A scroll mechanism does not make every package oil-free

广州广涡压缩机有限公司 presents scroll-airend development and manufacture and complete compressor packages from its Guangzhou Panyu location. Its company page names Guangwo and Jingba brands. Its catalogue separates standard-pressure, 1.6–3.0 MPa medium-pressure, oil-free, booster, airend and consumable selections.

The two existing products detailed here have an explicit lubricant grade and oil charge in their model tables. Choose their actual pressure point and supply boundary; the separate oil-free category does not change their lubrication mechanism.

Named participation in scroll-compressor standardization

The national standards platform names Guangzhou Guangwo among the drafting organizations for JB/T 11423-2013, general-use oil-injected scroll air compressors, displayed as current. This is a technical participation record, rather than an oil-free certificate or automatic compliance evidence for every current model.

GW-10D · LUBRICATED SCROLL

Pair the required pressure with its capacity

Complete original Guangwo GW-10D scroll cabinet image
The original manufacturer image is labelled GW-10D. Confirm the supplied cabinet and service clearances with its current drawing.

The table describes air cooling, integrated drive and 5 L dedicated scroll-compressor oil. This is a lubricated machine. The two rows below belong to different operating pressures.

0.8 MPa

1.05 m³/min

1.0 MPa

0.95 m³/min

Obtain the full flow test/reference conditions. Do not use the first point’s capacity as a guarantee at 1.0 MPa or infer package input from the model designation.

Envelope / mass
880 × 600 × 895 mm · 185 kg
Inlet-air limit
40°C maximum
Main supply
380 V · 50 Hz · 3 phase
Fan motor
150 W separately listed

Confirm the motor nameplate before sizing the supply

The source’s main-motor power cell contains 7.5 and an unexplained additional 6 together under kW. Obtain a clarified nameplate/electrical schedule, starter and protection details. A made-up single rating would be a poor basis for cables, breaker sizing or energy comparison.

State the sustained/peak use and acceptable pressure variation. Agree external receiver, dryer, filters and drains and the required oil/moisture/particle quality at the sampling point. Manufacturer residual-oil and noise figures without full test conditions are not universal process-air or room-noise guarantees.

GW-10D paired duties and installation information →

GW-15DHY16 · MEDIUM-PRESSURE PACKAGE

Specify the receiver and dryer as well as the compressor

The source pairs 1.0 m³/min with 1.6 MPa and lists a 420 L receiver. The original image shows the compressor, receiver and refrigerated-dryer section. Its readable cabinet marking is GW-15DHY; the 16 designation comes from the official model page/table.

It lists 4.5 L lubricant. A low residual-oil statement does not convert the scroll airend into an oil-free mechanism. Agree actual filter, dryer, condensate and air-quality scope for laser cutting or another sensitive process.

Envelope / mass
1700 × 720 × 1550 mm · 450 kg
Interface
Rc3/4
Cooling / inlet
Air-cooled · inlet 40°C maximum
Main supply
380 V · 50 Hz · 3 phase
Complete original Guangwo receiver-mounted GW-15DHY package with refrigerated dryer
Complete original package image. Agree vessel documents, dryer performance and actual offered accessories independently of its appearance.
Three components, three acceptance decisions
ComponentPublished factPut into the order
Scroll compressor1.0 m³/min at 1.6 MPa
4.5 L lubricant
Flow reference, duty curve, oil-service and electrical schedule
Receiver420 LDesign/working pressure, safety valve, inspection and destination vessel documents
Refrigerated dryerSeparate section pictured and tabulatedRating at 1.6 MPa, actual inlet temperature/flow, pressure dew point, drains and filters

Resolve two separate electrical ambiguities

The main-motor cell prints 11 plus an unexplained 6 under kW. The dryer cell prints 0.74 under a W heading, alongside 220 V and 4.2 A. Request current component nameplates and an electrical schedule; these figures are not silently converted into a confirmed package rating.

How does the nearby GW-30DH16 differ?

Its own page lists 2.0 m³/min at 1.6 MPa, 1000 × 640 × 1110 mm, 360 kg, Rc3/4 and 8 L lubricant. It does not specify the 420 L receiver/dryer assembly of GW-15DHY16. Compare the complete supply boundary instead of assuming identical packages with double output.

GW-15DHY16 package data and acceptance questions →

SITE PREPARATION · DOCUMENTS · SERVICE

Make the cabinet usable for the actual workshop

Air and ventilation

Use pressure at the machine after losses, demand peaks and the actual flow reference. Agree heat rejection, inlet/ambient conditions, service access and cabinet clearances.

Electrical and piping

Confirm main and auxiliary loads, starter, protection and drawings. A listed 380/50/3 supply does not establish compatibility with another frequency. Use actual outlet and receiver connection drawings.

Air-quality boundary

Define oil, moisture and particle limits, treatment/drain scope and sampling tests. The manufacturer's application list is not a process-specific purity approval.

Request the right manual set

The support area lists separate standard- and medium-pressure instruction manuals, principle drawings, application guidance and electrical manuals. The visible instruction-manual listing dates are from 2021; obtain the current revision and exact offered-model coverage.

Include oil grade and replacement intervals, oil/filter and scroll-service parts, dryer and receiver maintenance, commissioning tests and actual warranty/destination support. The compressor, vessel and dryer have distinct inspection and ownership needs.

Questions for a Guangwo enquiry

Are these two scroll selections oil-free?

The model tables explicitly list lubricant and oil charges. Specify actual treatment and air-quality acceptance; the separate oil-free catalogue heading is not evidence about these lubricated models.

Is the 420 L receiver enough for my demand peaks?

Provide the process cycle, permissible pressure swing, peak demand and actual compressor delivery. Receiver volume alone does not establish stable or uninterrupted supply.

Can I use a model name to choose the circuit breaker?

Obtain the current main and auxiliary nameplates, electrical schedule, starter and protection requirements. The source cells contain unresolved power entries and cannot establish a reliable electrical design.

Specify the scroll package and treatment boundary

Send the pressure-flow point, demand cycle, receiver/dryer scope, air-quality target, ambient conditions and electrical supply.

Prepare a Guangwo enquiry

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

Guangwo: Pair standard-pressure duties, or specify the medium-pressure compressor, receiver and dryer as a complete system.

Open RFQ