Nanjing Jiangning

Nanjing Hitachi: company history and a comparable compressor offer

Verified Nanjing manufacturing history, distinct DSP and SDS-U catalogue cases, pressure/flow conditions and the actual quoted production identity.

Original HITACHI Inspire the Next company mark

南京日立产机有限公司 · NANJING, JIANGSU

Company history and the offered compressor are separate decisions

  1. 2002Established on 27 December, according to the official group directory.
  2. 2005Jiangning relocation in February; air-compressor production began in April.
  3. 2010–2013Small-compressor production recorded in February 2010; group history records Nanjing oil-free production in fiscal 2013.

The Jiangsu provincial workplace-assessment notice of 19 May 2022 also identifies the Nanjing company. That is dated company/workplace evidence, rather than model performance or current certification.

50 HZ · FIXED SPEED · TWO DIFFERENT COOLING ARRANGEMENTS

DSP NEXT II: keep each pressure paired with its capacity

Two selected catalogue examples, with capacity referred to suction conditions
Configuration0.75 MPaG0.86 MPaG1.0 MPaG
DSP-90A5N2
Air cooled · 90 kW nominal motor
16.4 m³/min13.9 m³/min13.4 m³/min
DSP-110W5N2
Water cooled · 110 kW nominal motor
20.8 m³/min18.0 m³/min17.2 m³/min

Check the site utilities before choosing

The brochure lists 380/400/415 V, 50 Hz and inlet ambient 0–45°C. The 110W example requires a listed 180 L/min cooling-water flow with inlet water ≤35°C.

Its 2150 × 1520 × 1820 mm dimensions and 2200 kg mass differ from the 90A’s 2150 × 1520 × 1970 mm and 2130 kg. Add the actual ventilation and maintenance envelope to the installation drawing.

Open the DSP NEXT II selection notes →

SDS-U IS FIXED SPEED · SDS-UV IS A DIFFERENT SELECTION

SDS-U: pressure suffix and frequency change the row

These examples use the brochure’s 50 Hz, 20°C inlet, 0% relative humidity and 0.1 MPa absolute atmospheric pressure basis. They are separate configurations, rather than one unrestricted operating curve.

Original complete Hitachi SDS-U white cabinet and blue base
Original manufacturer SDS-U illustration. Confirm current model and production origin on the offered package.
Nominal 90 kW examples; capacity is at stated inlet conditions
ModelPressureCapacity
SDS-U90-C0.7 MPaG16.7 m³/min
SDS-U90-CH0.8 MPaG15.0 m³/min
SDS-U90-CU1.0 MPaG13.7 m³/min

The U90-C row lists 12 m³/h cooling water. Its 60 Hz capacity is 16.8 m³/min, which must not replace the 50 Hz figure. Confirm the selected water temperature, pressure and quality, rather than designing from the quantity alone.

Open the SDS-U comparison notes →

Define the receiving process, then freeze the package

01

Demand and electrical input

Send receiving-point pressure, network pressure loss, demand cycle, reference flow and site ambient/altitude. Obtain selected capacity and full/part-load package input at the agreed conditions.

02

Air quality at use

Specify moisture, particles and oil limits at the receiving point, dryer/filter and piping scope, sampling and acceptance. Oil-free compression is not a complete downstream air-treatment specification.

03

Origin, installation and support

Match exact model to manufacturer/origin. Agree utilities, electrical protection, ventilation, condensate, service access, commissioning, genuine spares, conformity and warranty responsibilities.

Questions before comparing two offers

Does Nanjing’s compressor history prove the current DSP offer is made there?

No. Obtain the quotation’s manufacturing company and plant. The August 2025 China DSP brochure names a Changshu entity; the Nanjing history records earlier production.

Is the 90 kW motor figure the power my electrical meter will see?

No. Ask for total package input and its load/control conditions, including auxiliaries. Motor output and package electrical input are different quantities.

Can I compare these capacities directly with an Nm³/min offer?

Only after agreeing the flow reference and conversion. These catalogue quantities are referred to inlet conditions; normal-volume conditions must be specified separately.

Prepare one comparable Hitachi duty

Include pressure and flow basis, demand cycle, supply frequency, cooling utilities and point-of-use air quality. Ask the offer to identify the actual manufacturer and origin.

Prepare the Hitachi selection RFQ

Specification pages

Specification pages for Hitachi IEC product types

All spec pages
DutyWrite on the RFQ
Compressor for a food factory Food air is a validation file. Class, test point and treatment matter as much as kW. A general 8 bar screw without papers is not a food quote.
Compressor for a pharmaceutical plant Pharma procurement is a document pack: IQ/OQ support, material certs, residual oil. The machine is the easy part if the RFQ lists the papers.
Class 0 oil-free compressor Class 0 means a stated test method at a stated point in the air system. An oil-free airend without a paper is not Class 0 on this desk.
Oil-free screw compressor manufacturers in China Oil-free screw is a different factory from oil-injected screw. Dry airends and water-lubricated airends are also different quotes. Name the architecture.

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

Hitachi IEC: Verified Nanjing manufacturing history, distinct DSP and SDS-U catalogue cases, pressure/flow conditions and the actual quoted production identity.

Open RFQ