Feihe Shanghai: water-lubricated, mobile and centrifugal air duties
Match the air duty to its water circuits, outdoor engine package or central air-room conditions.
SHANGHAI FEIHE · BAOSHAN
Three air-supply paths, with different site requirements
上海飞和压缩机制造有限公司 identifies itself as Feihe Group’s wholly owned air-compressor manufacturing subsidiary in Shanghai’s Baoshan industrial area. Its company page describes research and testing centers and a range covering screw, mobile and centrifugal air equipment.
The original company site publishes the adjacent Feihe plant-area photograph. Treat the company description and historical imagery as context; use the offered model’s manufacturing address, inspection records and delivery documents to review your order.
Original manufacturer-site plant-area image. It does not establish today’s available capacity or the production origin of every offered configuration.
Original FHOGDWY-132 family image. The selected PM and WYH rows below describe different models.
The water-lubricated page separates standard WY, PM variable-speed, high-pressure WYH and low-pressure WYL tables. These are different selections. The selected PM rows give a range at a stated pressure, while a WYH row gives a different high-pressure duty.
Water lubrication identifies the compression method. Define the process’s oil, moisture and particle limits, downstream treatment, sampling point and acceptance procedure. Obtain model-scoped purity evidence; the company’s ISO9001 wording does not define an air-purity class.
Selected PM rows at 0.8 MPa — water quantities are separate utilities
Model / motor
Published volume range
Cooling water
Lubrication water
FHOGDWY-PM8F · 7.5 kW
0.4–1.2 m³/min
2 T/H
10 L/min
FHOGDWY-PM22F · 22 kW
1.1–3.7 m³/min
5 T/H
30 L/min
The PM table states cooling-water inlet below 32°C. Neither water column is verified site make-up consumption. Agree water quality, circuit pressure, supply/return conditions, replenishment, drains, treatment and protective functions. Obtain the complete volume-reference conditions and pressure basis for the air duty.
Higher pressure needs its own row
FHOGDWYH-22F lists 22 kW and 2.0 / 1.9 / 1.8 m³/min at 1.6 / 2.0 / 2.5 MPa. Do not combine that pressure with the larger PM22F flow. PM22F instead gives 0.9–3.2 at 1.0 MPa and 0.8–2.8 m³/min at 1.25 MPa.
The PM22F selected installation data are 1400 × 1000 × 1520 mm, 780 kg, a 1-inch outlet and 380 V / 50 Hz IP54 motor supply. Leave space for cooling-water interfaces and service access, and obtain the current drawing for the actual offered machine.
FHOGY DIESEL · OUTDOOR TOOL DEMAND
Keep the driver and tool pressure together
The mobile table contains both diesel FHOGY and electric FHOGYD. These selected points belong to the diesel rows. Engine selection and tow arrangement remain part of the specific offer.
FHOGY-30
3.2 m³/min at 0.8 MPa; 3.0 at 1.0 MPa
FHOGY-75
6.6 m³/min at 0.8 MPa; 6.0 at 1.0 MPa
FHOGY-160
19.0 m³/min at 0.8 MPa; 16.0 at 1.0 MPa
FHOGY-240
32.0 m³/min at 0.8 MPa; 28.8 at 1.0 MPa
Send simultaneous tool consumption, pressure at the tool inlet, hose length and site elevation/temperature. Confirm engine make/model, emissions for the destination, fuel and service availability, outlet connections and air treatment. Obtain exact transport/lifting drawings and any trailer, brake or road requirements.
Original towable family photograph from the mobile product page. The image is not proof of every engine/chassis configuration or road approval.
FHLY GEARED CENTRIFUGAL AIR
Start with the inlet conditions and the operating map
Original FHLY family product photograph. Select the actual core, motor and system arrangement from the proposed duty.
The table expressly uses inlet-volume flow and publishes discharge pressure in kg/cm². The figures are selection bands, not a paired duty point or a normal-volume/FAD rating. Preserve the pressure unit and obtain the offered model’s exact pressure basis.
Separate FHLY selection bands — all list 5–10 kg/cm² discharge pressure
Model band
Inlet flow
Motor band
FHLY40-90
42–90 m³/min
185–400 kW
FHLY90-140
90–140 m³/min
400–700 kW
FHLY140-200
140–200 m³/min
700–1050 kW
FHLY200-300m
200–300 m³/min
1050–1500 kW
Reference and control
The published reference uses 1 bar absolute inlet pressure, inlet temperature below 35°C and cooling water below 32°C. Supply the actual inlet humidity, ambient/altitude, water conditions and demand cycle. Ask for the map, minimum stable flow, package input and IGV / anti-surge / blow-off behavior across that cycle.
Included equipment and interfaces
The page describes a geared package, horizontally split casing and water-cooled heat exchangers. Its standard scope names core, inlet/discharge expansion joints, IGV, cooling, lubrication, controller, blow-off and discharge check valve. Inlet filter, monitoring, acoustic enclosure and motor protection are selectable items; agree the actual scope and protection class.
A Shanghai regulator’s January 2023 report lists Feihe’s FHOGD-22F-8, batch FHY2022301, among samples meeting the inspected energy-label metrology requirements in its 2022 check. This is a result for that sample and inspection scope. It does not certify every water-lubricated, diesel or centrifugal machine.
Model and performance
Full offered model and manufacturing address, pressure-matched duty, flow reference, package input and load/control limits; the relevant purity or engine/emissions requirements.
Site and included scope
Water circuits or engine/transport interfaces, electrical supply, inlet/discharge piping, cooling and access drawings, receiver/treatment scope and destination documents.
Inspection and long-term use
Order-specific test/inspection records, current certificate issuer and model scope where relevant, manuals, wear-parts schedule and agreed installation, commissioning and service responsibilities.
Questions specific to these Feihe paths
Is lubrication-water quantity the same as water purchased by the site?
The source provides separate cooling-water and lubrication-water quantities. Define the actual circulation, replenishment, treatment and drain arrangement before calculating site consumption or utility cost.
Can the electric FHOGYD table supply an FHOGY diesel rating?
Use the exact driver/model row. Diesel and electric versions have different configurations and listed duties, and the actual engine or motor documents must match the offered machine.
Can FHLY inlet flow be compared directly with a screw model’s stated flow?
Establish the same reference pressure, temperature, humidity and flow definition first. FHLY expressly lists inlet volume; a screw table’s short flow figure does not by itself establish an identical reference.
Specify the Feihe air-supply duty
Send the chosen family, pressure/flow reference, load profile and water, engine or air-room conditions.
Most aeration trains want low-pressure blowers. If this RFQ is actually 7–8 bar plant air for valves and instruments, say so — it is a different machine from a maglev blower.