Haigair: air demand, control choice and room planning
Compare actual HPV and DBV duty points, clarify alternate-model data and prepare a matched fixed-speed or VSD proposal.
海格尔压缩机(青岛)有限公司 · JIAOZHOU, QINGDAO
Start with air demand, pressure and control behavior
Haigair describes development, manufacture and sales of screw air compressors. Its portfolio includes fixed-speed, standard-pressure PM VSD, two-stage VSD and low-pressure equipment, with separate oil-free and centrifugal categories.
“Standard-pressure” translates the company’s 常压 category. It does not mean atmospheric-pressure compression: the reviewed model tables list 0.8 MPa discharge. Low-pressure, laser-cutting and oil-free products have separate scopes.
HPV-15A / DBV-75A · FLOW AT THE LISTED PRESSURE
Keep model, pressure and installation data together
Two actual official model tables; flow-test reference and offered electrical configuration must be agreed
Model and family
Published duty
Installation data
Cooling and outlet
HPV-15A Single-stage PM VSD
11 kW 1.72 m³/min Listed discharge 0.8 MPa
Approx. 900 × 800 × 1343 mm 260 kg
Air-cooled DN25
DBV-75A Two-stage PM VSD
55 kW 12 m³/min Listed discharge 0.8 MPa
Approx. 1900 × 1250 × 1640 mm 1600 kg
Air-cooled DN65
The pages separately list 0.7, 0.8 and 1.0–1.25 MPa pressure options. The listed flow is not a guarantee at every pressure or speed. Request the selected machine’s reference conditions and performance curve; the “air-processing volume” label is not independently verified FAD.
HPV-15A: complete official model image and original brand watermark. Select to view the original.DBV-75A: complete official cabinet image. Appearance and label do not establish a measured efficiency or certification.
Electrical and air quality
Both pages offer customized 220/380/415/440/480 V; confirm phase and frequency. The tables list an oil/gas vessel and oil filter. Specify actual lubrication and downstream drying/filtration rather than treating these as oil-free models.
Alternative DBV-50A: reconcile first
Its title says 37 kW, but the operating-power table says 55 kW, with 7 m³/min at 0.8 MPa. Obtain the correct motor and duty sheet before comparison. DBV-75A’s 55 kW title and table agree.
INSTALLATION ARTICLE · VERIFY AGAINST THE MODEL MANUAL
Check the room before choosing the cabinet
Wall and service access
Haigair’s article normally recommends 1.5 m to the wall, with 0.75 m as a restricted-space minimum. Confirm the offered model’s door, filter and component-removal clearances; the article does not replace its manual.
Temperature and airflow
The article recommends a room between 0 and 38°C, dry and well ventilated, avoiding excessive dust, oil and moisture. Agree intake/hot-air-discharge routes and the machine’s actual permissible conditions.
Structure and operation
Check a level, firm floor and structural/vibration needs for an upper-floor installation. Establish operating records, trained operators and planned maintenance using the delivered manual.
The management guidance calls for recording operating time/status, maintaining components and escalating abnormal conditions to support. For the proposal, request the actual filter, separator and lubricant schedule, cooling-cleaning needs and safe service access.
DEMAND PROFILE → OFFERED PERFORMANCE → ACCEPTANCE
Compare package performance under your actual conditions
Supply the demand: base/peak flow, changes during the shift, operating hours, point-of-use pressure, distribution losses and existing compressor/receiver arrangement.
Agree the performance: flow reference, pressure, usable turndown or load/unload sequence, package input and supplied air quality/treatment. Savings or silence language requires measured conditions.
Define the delivery: voltage/phase/frequency, cooling and service access, controls/protection, manuals, consumable parts and acceptance records linked to the actual machine.
The product tables state a one-year warranty and online service. Agree commencement, exclusions, commissioning/training, parts and destination attendance/costs in the order.
Questions for a Haigair offer
Does the HPV-15A flow apply at 1.25 MPa too?
The source lists 1.72 m³/min and 0.8 MPa separately from other pressure options. Request the actual offered curve and reference conditions at the required pressure.
Which power should be used for DBV-50A?
The title/table mismatch remains unresolved. Obtain the actual drive and duty sheet. The reviewed DBV-75A example consistently lists 55 kW.
Does a PM motor make these oil-free compressors?
No. These tables list oil/gas vessels and oil filters. Specify gas-path arrangement and required outlet quality; oil-free is a separate portfolio category.
Send the air demand and room constraints
Choose fixed-speed, HPV single-stage or DBV two-stage, then provide pressure, flow profile, operating hours, air quality and electrical/site conditions.
Chinese plants build 50 Hz 380 V packages every day. They cannot retag a 60 Hz 460 V nameplate in the quotation without a motor change. Write the supply first.
China already has more screw-compressor storefronts than a buyer can audit. This desk lists manufacturing plants against a duty sheet — kW, bar(g), FAD — and routes one English RFQ.
Choose the air system from the laser maker's gas specification. The compressor motor rating and laser power do not, by themselves, determine the required pressure, flow or air quality. Identify whether the supply is for cutting assist gas, machine services or both before requesting a package.
Product information
Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
Haigair: Compare actual HPV and DBV duty points, clarify alternate-model data and prepare a matched fixed-speed or VSD proposal.