Boluo

Hande: compare the pressure version and compression architecture

Two-stage PM screw pressure points, distinct oil-free cooling routes, piston delivery and the records needed to define the complete station.

HANDE · Guangdong · Boluo / Huizhou

Start with the compression architecture, then define the complete station

Guangdong Hande Precision Machinery is based in Yuanzhou, Boluo. Its official history dates the company's formal establishment to 2016, separately from the founder's earlier compressor repair and sales experience.

The stated operating model combines development, production and sales, centered on two-stage and PM variable-speed screw equipment. Its catalog also separates oil-free, integrated packages, vacuum, piston and air-treatment divisions. Purification, filtration and separation are system offerings; their inclusion belongs on the actual equipment list.

Which decision are you making?

  • Factory air: choose the HD-EPM2T working-pressure version and the corresponding delivered air, package dimensions and controls.
  • Process air: distinguish dry screw, scroll and water-lubricated screw, then define quality limits and treatment at the users.
  • Piston or higher-pressure duty: compare actual air delivery, receiver and cooling requirements, without substituting piston displacement.

HD-EPM2T · Two-stage PM variable-speed screw

The pressure version changes the technical comparison

Official Hande two-stage screw compressor photograph marked HD-EPM2T75
Official range image marked HD-EPM2T75. Approve the drawing for the selected pressure version.

HD-EPM2T37 · 37 kW example

The table lists air cooling, −5 to 45°C ambient, 950 kg and 1,950 × 1,100 × 1,390 mm. Its outlet changes from DN65 at 0.5 MPa to Rp1½ at the three higher pressures.

HD-EPM2T37: discharge pressure paired with listed air quantity
PressureAir quantity
0.5 MPa · 5 bar8.2 m³/min
0.8 MPa · 8 bar6.8 m³/min
1.0 MPa · 10 bar6.1 m³/min
1.25 MPa · 12.5 bar5.2 m³/min

At 75 kW, do not reuse the 5 bar package size for the 8 bar offer

HD-EPM2T75 · 0.5 MPa
18.8 m³/min
2,630 kg · DN100
2,990 × 1,700 × 1,963 mm
HD-EPM2T75 · 0.8 MPa
15.6 m³/min
2,110 kg · DN65
2,590 × 1,500 × 1,640 mm

The 1.0 and 1.25 MPa rows list 13.0 and 11.0 m³/min. Keep the full model and pressure on the offer and drawing; obtain performance reference conditions and complete-package input before comparing energy.

Plan the compressor room around access

The manufacturer describes independent air-intake paths for the filter, motor and electrical cabinet, segmented coolers and a lifting/rotating oil-separator vessel cover. Request ventilation routing, cooler removal/cleaning clearances and overhead space for the cover on the actual arrangement.

HD-EPM2T pressure points and installation scope →

Process air · Architecture and utilities

“Oil-free” covers three different equipment routes

HD-DSPM · Dry screw

The source describes a compression chamber without oil and non-contact rotors with synchronizing gears. Obtain the actual service manual; this does not mean every part of the machine is maintenance-free.

HD-SRL · Scroll

HD-SRL4 lists 3.7 kW and 0.36 m³/min at 0.8 MPa, with air cooling, Rp½, 150 kg and 650 × 700 × 1,015 mm. It is a separate architecture from the large dry screw.

HD-ZW · Water-lubricated screw

The catalog identifies this as another route. Define the actual selected model, water-system conditions and maintenance requirements rather than borrowing a dry-screw row.

Official Hande dry oil-free screw compressor photograph marked HD-DSPM90
Official HD-DSPM90 photograph. The larger water-cooled selection below has separate installation requirements.
Two dry-screw table entries at 0.8 MPa; different cooling and physical requirements
Model / dutyUtilitiesPhysical package
HD-DSPM90
90 kW · 14.9 m³/min
Air-cooled · 0–40°C ambient
DN65
2,850 kg
3,150 × 1,750 × 1,800 mm
HD-DSPM200
200 kW · 31.3 m³/min
Water-cooled · 0–40°C ambient
DN100
5,200 kg
3,800 × 2,280 × 2,200 mm

Specify oil, particle and moisture limits at the process users. Request the selected equipment's applicable quality/test documents and treatment capacity, pressure loss and drainage. A division label does not establish a universal certificate, and an oil-free compression route still needs a defined air-treatment system.

Dry-screw and smaller scroll selection details →

HDW / HD-SPCF · Delivery and pressure-rated systems

Piston displacement is not the delivered-air quantity

Original Hande HDW piston compressor with receiver from its product gallery
Official HDW range photograph. Confirm the ordered motor, receiver, controls and pressure version.

HDW6708 · 0.8 MPa example

Listed air quantity0.67 m³/min

Separate piston displacement1,068 L/min

The table gives 5.5 kW, a 150 L receiver and 198 kg. Use the discharge quantity when defining demand; the displacement column is a different measure.

The HDW external dimensions have an apparent unit/scale inconsistency. Obtain the final approved drawing before arranging transport and installation; do not infer a size from an assumed conversion.

Higher-pressure piston example

HDW60025 lists 0.60 m³/min at 2.5 MPa, 7.5 kW, displacement 830 L/min, a 250 L receiver and 362 kg.

Agree the actual operating cycle, pressure-rated receiver and piping, safety devices and destination inspection requirements.

A separate screw/piston serial system

HD-SPC67F-40 lists 6.0 m³/min at 4.0 MPa and 67 kW. Its water-cooled table entry includes 20 t/h circulating-water flow, Rc1½ water connection, DN40 air outlet, 3,200 kg and 2,840 × 1,500 × 1,480 mm; ambient 0–40°C.

Specify the inlet and water-system conditions for the offered arrangement. The wheeled HDW photograph does not describe this larger system.

HDW and serial-compression requirements →

Factory evidence · Performance acceptance

Connect the testing facility to the ordered machine's record

Hande factory gallery photograph of its monitoring center
Original monitoring-center image from Hande's factory gallery. A facility photograph is not a performance certificate.

The published history describes an energy-efficiency testing laboratory established at the factory in 2019. Request the ordered model's pressure, air-delivery and package-input results, reference conditions and relevant calibration.

A Guangdong government 2022 high-tech-enterprise list names this exact company in Huizhou. This is historical company recognition; current model certification and performance acceptance require their own applicable documents.

Define destination service and controls

The service page describes consultation, system layout/selection, installation/commissioning, operator-maintenance training, running-service records, repairs and upgrades. Agree the responsible provider and coverage at the actual destination.

Its library contains multiple controller/inverter manuals. Identify the installed hardware and document revision; the whole library is not one machine's operating manual.

Attach a model and station brief

  • Required pressure and normal/peak/minimum demand by shift.
  • Full model/pressure version, supply, ambient and cooling utilities.
  • Room access, ventilation, maintenance clearances and handling plan.
  • User air-quality limits, treatment/storage/drainage list and existing controls.
  • Approved drawings, test/inspection documents, manuals, consumables and commissioning responsibilities.
Send a Hande model and station brief →

Hande selection questions

Can I compare every HD-EPM2T75 by its largest flow figure?

The 18.8 m³/min entry belongs to 0.5 MPa. At 0.8 MPa the table lists 15.6 m³/min, with different package size, mass and outlet. Keep pressure and version on the comparison.

Does oil-free mean the complete machine needs no maintenance?

The dry-screw description concerns the compression chamber. Obtain the service manual and actual consumables for the selected architecture and model, along with applicable process-air documents.

Is HDW6708's delivered air 1,068 L/min?

That is the piston-displacement column. Its listed discharge quantity is 0.67 m³/min at 0.8 MPa. The table separates these measures.

Can HD-DSPM200 replace an air-cooled package without a utility change?

The selected entry is water-cooled. Obtain cooling-water requirements, connections and arrangement for the offered model before comparing it with air-cooled HD-DSPM90.

Do the service-page manuals all apply to my controller?

Identify the actual supplied controller/inverter and document revision. Agree commissioning, training and destination support with the selected hardware and offer.

Specification pages

Specification pages for Hande product types

All spec pages
DutyWrite on the RFQ
22 kW VSD screw compressor 22 kW VSD is a flow band, not a single nameplate FAD. The plant needs min/max flow at the working pressure, or it will quote a fixed-speed machine with an inverter sticker.
Class 0 oil-free compressor Class 0 means a stated test method at a stated point in the air system. An oil-free airend without a paper is not Class 0 on this desk.
Piston compressor manufacturers in China Piston packages in China run from workshop portables to API-style process recips. Those are not one RFQ. Write pressure stages and whether the air must be oil-free.
13 bar rotary screw compressor 13 bar(g) is a laser and textile pressure, not a general 8 bar plant. Write FAD at 13 bar and the kW the site can feed.

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

Hande: Two-stage PM screw pressure points, distinct oil-free cooling routes, piston delivery and the records needed to define the complete station.

Open RFQ