Fuzhou

Snowman SRM & RefComp refrigeration compressors

Compare open-drive SRM and semi-hermetic SW3 refrigeration routes, then define the thermal duty and supply boundary.

Snowman's compressor business

Company
Fujian Snowman Group Co., Ltd.
Base
Changle, Fuzhou, Fujian
Listed identity
Shenzhen · 002639
Refrigeration brands
SRM · RefComp
Prepare Snowman RFQ

Define the compressor, then the refrigeration system

Snowman connects compressor technology with industrial refrigeration, cold-chain systems and ice-making equipment. Its company history dates the business to March 2000 and its Shenzhen listing to December 2011. The group identifies SRM and RefComp as its compressor brands, while SNOWKEY covers ice-making equipment.

That portfolio gives a buyer several possible supply boundaries: a compressor, an assembled refrigeration unit or a wider cooling/ice-making system. Start by deciding which boundary your enquiry covers, then name the compressor family and thermal duty.

Open drive or semi-hermetic: what changes for the buyer?

Snowman SRM-12 open-type screw refrigeration compressor

SRM · external drive integration

Open-type single-stage screw

The manufacturer lists six series, from SRM-12 through SRM-41, with 19 models. Its open construction requires a drive arrangement to be agreed as part of the supply.

  • Match motor, coupling, speed and alignment responsibilities.
  • Define oil-system, cooling and capacity-control scope.
  • Check seal service access and the proposed arrangement drawing.

The SRM page describes adjustable built-in volume ratio and continuous capacity control. Request the exact model's selection and control arrangement for your temperature lift and load profile.

Review the SRM family →
RefComp SW3H semi-hermetic screw refrigeration compressor

RefComp · integrated motor construction

SW3H or SW3L semi-hermetic screw

SW3H addresses medium/high-temperature refrigeration; SW3L addresses low-temperature duties. The cited SW3 family has 28 models. The photo is an SW3H example.

  • Match the application subgroup before motor power.
  • Confirm suction-gas motor cooling and operating envelope.
  • Specify stepped or continuous capacity-control configuration.

The catalogue describes temperature, phase-loss and reverse-rotation protection and an integrated suction filter. Obtain the model's electrical/protection requirements and integration instructions.

Review the SW3 route →

Read each family range within its own scope

SRM single-stage open screw

Family displacement
265–10,000 m³/h at 2,960 rpm
Listed refrigerants
R717, R404A, R507A
Catalogue construction
5+7 rotor profile · ductile-iron body
Published control description
10% to full-load continuous adjustment · adjustable Vi

The cited 2.8 MPa body working-pressure figure is a mechanical reference. It is not the evaporating/condensing operating point or a cooling-capacity rating.

RefComp SW3 semi-hermetic screw

Family displacement
118–700 m³/h at 2,960 rpm
Family motor range
30–240 HP
Listed refrigerants
R507A, R404A
Application split
SW3H medium/high temperature · SW3L low temperature

These are range-wide figures. Do not pair the lowest or highest motor rating with a displacement endpoint without the exact model table and thermal selection.

Different projects need different starting information

New cold store

Establish the refrigeration load and room/product temperatures before selecting a compressor. Include operating schedule, pull-down requirement, heat-rejection conditions and redundancy. Identify whether the supplier should select a unit or only quote an already selected compressor.

Industrial process cooling

State the fluid or process to be cooled, inlet/outlet temperatures, flow and load range. Define refrigerant and condenser conditions where available. Clarify whether heat exchangers, oil system, controls and electrical panel belong in the offer.

Replacement compressor

Send the old nameplate, model suffix, refrigerant, measured conditions and available installation space. For SRM include external drive/coupling details; for SW3 include voltage, protection and control arrangement. Similar displacement alone does not prove interchangeability.

Approve the supply in three stages

  1. Confirm the selection

    Request a current model selection with cooling output, absorbed power and permitted envelope at the same conditions. Include minimum load and the chosen capacity-control method.

  2. Confirm the integration

    Approve arrangement, connections, electrical/protection requirements, oil and cooling scope. For an open-drive machine, assign motor/coupling and alignment work. Agree which components are included and which are site-supplied.

  3. Confirm release and support

    Agree model/origin/nameplate records, applicable product documentation, inspection requirements and operating instructions. Identify commissioning responsibility, service-part numbers and destination support in the quotation.

Prepare a Snowman enquiry with a clear boundary

Compressor-only enquiry

Send SRM or RefComp family and model, refrigerant, evaporating/condensing conditions, speed and voltage/frequency. Specify capacity control, replacement constraints and required documentation.

Packaged refrigeration enquiry

Add the thermal load, process/room conditions, heat-rejection utilities, load schedule, redundancy and installation location. Request an itemised boundary covering compressor, drive, oil system, heat exchangers, controls, testing and startup.

Compare equivalent offers

Keep refrigerant and selection conditions consistent across quotations. Compare actual selected cooling output and input power, supply scope and acceptance obligations rather than the family displacement headline.

Questions before choosing SRM or RefComp

Does an SRM-12 have the whole 265–10,000 m³/h range?

No. That range covers six SRM series and 19 models at 2,960 rpm. Obtain the exact model's displacement and refrigeration selection before using either endpoint.

Is SW3H the correct option for a low-temperature duty?

The published split places SW3H in medium/high-temperature applications and SW3L in low-temperature applications. Select the named model against the required refrigerant and operating envelope.

Is the 2.8 MPa body figure my system's operating pressure?

It is the catalogue body working-pressure reference. The refrigeration operating point and design requirements must be established for the selected refrigerant and system, including applicable pressure-equipment requirements.

Does ordering a compressor include a refrigeration unit?

Agree the boundary explicitly. A bare compressor entry does not establish inclusion of the motor, oil system, heat exchangers, electrical controls, assembly or commissioning. Ask for an itemised offer.

Specification pages

Specification pages for Snowman product types

All spec pages
DutyWrite on the RFQ
Refrigeration screw compressor manufacturers in China A refrigeration screw compressor is selected for a refrigerant and operating conditions. Start with required cooling capacity, evaporating and condensing temperatures, electrical supply and the system arrangement. An air-compressor pressure rating or a motor nameplate alone cannot define this duty.

Product information

Information reviewed 2026-09-28. Specifications apply only to the models and conditions stated.

Snowman: Compare open-drive SRM and semi-hermetic SW3 refrigeration routes, then define the thermal duty and supply boundary.

Open RFQ