CMW15-0.8
4 × 3.7 kW motors
0.2–0.8 MPa range
1660 L/min listed capacity
1400 × 800 × 1280 mm
350 kg · 1-inch outlet
Taizhou Bay New Area
Choose the cooling version, establish the medium-pressure duty or plan direct-drive scroll modules.

CMN / XINMAIEN · TAIZHOU BAY NEW AREA
辛麦恩科技股份有限公司 is the company named on CMN’s official site, with its operating location in Taizhou Bay New Area, Zhejiang. The company presents single-screw development, manufacture and service. Its technology-history narrative is distinct from the incorporation history of the present Chinese legal entity.

CM/PV · WATER-LUBRICATED PM VARIABLE SPEED

The actual CM/PV table labels flow as FAD and distinguishes air-cooled F parameters from water-cooled data. Keep the selected pressure row, version and full flow-reference conditions together.
| Version | Dimensions / mass | Site decision |
|---|---|---|
| Air-cooled F | 1900 × 1000 × 1635 mm 1023 kg | Ventilation, heat rejection and service clearances |
| Water-cooled | 1680 × 1000 × 1335 mm 873 kg | DN25 water connections; 5 T/h cooling water at the table’s 32°C inlet reference |
The CM22PV row lists a 1-inch air outlet. Cooling duty is not measured make-up consumption. Agree water quality, pressure, supply/return and drain arrangement, and the separate lubrication-water circuit. For air cooling, use the F-version drawing and ambient/ventilation limits.
Other selected 0.8 MPa rows are CM08PV(F), 7.5 kW and 0.45–1.15 m³/min; CM75PV(F), 75 kW and 5.16–12.90; CM315PV, 315 kW and 21.80–54.50. These are separate models, not one machine’s complete operating range.
CM/PV selected duties and cooling details →CM/GPV · TWO STAGES, TWO DRIVES
The manufacturer describes water-lubricated, water-cooled two-stage compression with separate permanent-magnet drives. Its table contains both fixed-speed CM/G and variable-speed CM/GPV entries. The figures below belong to GPV.
CM130GPV appears twice. One entry gives a 2.0–3.0 MPa band with 5.4–13.5 m³/min; the other gives 2.0–4.0 MPa with 4.0–10.2. The pressure band is part of the selected configuration. Neither interval proves maximum flow at every pressure in the band.

Both published CM130GPV entries carry these values. Do not treat the two power cells as a single motor rating or measured total package consumption.
For a blowing process, give pressure at the use point, cycle and peak draw, receiver/control concept and minimum sustained demand. Obtain the pressure-matched curve, full volume reference, individual drive data, sequencing and cooling-water requirements. Align pressure-rated piping/receiver documents, drying/filtration and process-air acceptance. If the enquiry says “30 bar”, the 30 bar oil-free duty page explains how to state gauge or absolute pressure and which documented configuration to request.
CM/GPV configuration bands and installation figures →CMW · DIRECT-DRIVE OIL-FREE SCROLL

CMW uses directly driven permanent-magnet scroll airends, with single and multi-airend arrangements. The source describes pressure/warning/maintenance indications and a larger touchscreen on packages with three or more airends; confirm the current supplied controller.
The detailed table gives CMW2.2-0.8: 255 L/min and CMW2.2-1.0: 215 L/min, both at a 2.2 kW motor rating. The suffix matters. Obtain the exact capacity-rating pressure and reference rather than treating the table’s pressure range as constant output.
4 × 3.7 kW motors
0.2–0.8 MPa range
1660 L/min listed capacity
1400 × 800 × 1280 mm
350 kg · 1-inch outlet
6 × 4.5 kW motors
0.2–1.2 MPa range
2160 L/min listed capacity
1400 × 800 × 1870 mm
650 kg · 1-inch outlet
State the required continuing flow and acceptable interruption. Ask for the actual start/stop sequence, running-hour rotation, isolation and safeguards, plus available package output under the intended maintenance condition. A module count does not establish certified proportional residual output.
Leave cooling and removal clearances around the cabinet. Agree the complete dryer/filter and drain scope and moisture, particle and oil targets at the use point. Medical, food or laboratory application wording does not replace the destination’s system and acceptance requirements.
TECHNICAL PARTICIPATION · ACTUAL DELIVERY SCOPE
The national standards platform names 辛麦恩科技股份有限公司 among drafting organizations for plan 20250138-T-604, a revision for general-use oil-injected single-screw air compressors. The observed status is approval in progress. This is a technical-participation record in a different scope, not certification of these oil-free machines.
The company’s service page separates consultation, delivery/start-up and training, after-sales, return visits and maintenance. Its domestic response wording is not a global response-time commitment; put destination coverage, personnel, travel, parts and responsibilities into your quotation.
Model, pressure suffix or band, cooling and drive arrangement, full performance/test reference, actual package input and site conditions.
Current issuer/report and model scope behind any Class 0 claim, particle/moisture requirements, treatment and sampling point. Compressor mechanism alone does not establish a complete food, medical or breathing-air specification.
Cooling or ventilation, electrical and piping interfaces, access drawings, tests, manuals, wear parts, destination documents, commissioning and ongoing service terms.
CM/PV publishes air-cooled F and water-cooled installation data. Select the actual cooling version and obtain its lubrication-water and heat-rejection diagrams; the water-cooled table’s utility figure does not describe every F installation.
The same model label has two configuration bands. Request a paired pressure-flow curve for the selected configuration; an interval across a band is not that paired duty.
The complete air system needs its own purity, treatment, monitoring, destination requirements and acceptance records. Obtain documentation for the actual application and offered model.
Send the family, pressure/flow reference, demand cycle, cooling or module arrangement and process-air targets.
Prepare a CMN enquirySpecification pages
| Duty | Write on the RFQ |
|---|---|
| 40 bar PET compressor | PET blowing at 40 bar(g) is a high-pressure oil-free duty. Cavities, bottle volume and recovery pressure size the skid — not the word “PET compressor”. |
| Class 0 oil-free compressor | Class 0 means a stated test method at a stated point in the air system. An oil-free airend without a paper is not Class 0 on this desk. |
| Compressor for PET bottle blowing | Bottle blowing is a high-pressure oil-free process. The blower OEM’s pressure and the cavity count size the compressor, not the word PET. |
| Oil-free screw compressor manufacturers in China | Oil-free screw is a different factory from oil-injected screw. Dry airends and water-lubricated airends are also different quotes. Name the architecture. |
Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
CMN: Choose the cooling version, establish the medium-pressure duty or plan direct-drive scroll modules.
Open RFQ