PET / HP

CMN CM/GPV medium-pressure oil-free screw — dual-drive configurations — CMN / Xinmaien Technology (Taizhou)

CMN CM/GPV medium-pressure oil-free screw — dual-drive configurations · CMN / Xinmaien Technology (Taizhou)

CMN CM/GPV medium-pressure oil-free screw — dual-drive configurations — official catalog illustration
CMN CM/GPV medium-pressure oil-free screw — dual-drive configurations — manufacturer catalog illustration

Datasheet

Product overview

Power: Dual drives — preserve separate motor cells · Pressure: Configuration bands2.0–3.0 or2.0–4.0 MPa · Flow: CM130GPV:5.4–13.5 or4.0–10.2 m³/min;bands differ

CMN describes CM/GPV as a two-stage, dual-drive permanent-magnet variable-speed oil-free screw selection using water lubrication and water cooling. Its source table mixes CM/G fixed-speed rows and GPV variable-speed rows. The selected GPV figures here are intervals within a stated pressure band, not a pressure-by-pressure performance curve or a guarantee of maximum flow at the highest pressure.

CM75GPV publishes 2.0–3.0 MPa and 2.5–6.3 m³/min, with separate 30 and 45 kW motor cells, 18 T/h cooling water, DN32 outlet, 2000 × 1900 × 1480 mm and 2250 kg. CM100GPV gives 2.0–4.0 MPa and 3.3–8.2 m³/min, separate 55 and 55 kW cells, 21 T/h, DN32, 2500 × 2000 × 1550 mm and 2450 kg. Preserve the individual motor entries and obtain the actual drive arrangement and package input rather than assigning one motor rating from the model number.

The CM130GPV name occurs twice: 2.0–3.0 MPa with 5.4–13.5 m³/min, and 2.0–4.0 MPa with 4.0–10.2. Each shows separate 55 and 75 kW cells, 35 T/h water, DN32, 2500 × 2000 × 1550 mm and 3000 kg. The pressure band is therefore part of the configuration. The CM242GPV family image is marked 4.0 MPa; its table interval is 9.6–24.0 m³/min across 2.0–4.0 MPa, with separate 110 and 132 kW cells, 50 T/h water, DN40, 2760 × 2250 × 1670 mm and 3950 kg. The image marking does not establish 24.0 m³/min at 4.0 MPa.

For a blowing process, provide process pressure, cycle and peak draw, receiver volume/control concept and minimum sustained load. Request the pressure-matched curve, flow reference, individual drive data, total package input and sequencing. Agree cooling-water temperature/quality/quantity and supply/return interfaces; cooling duty is not measured make-up usage. Define downstream drying, filtration, pressure-rated piping/receiver documents and process-air sampling. Obtain current model-scoped purity reports, drawings, tests, manuals, wear parts and commissioning/support scope.

Catalog referenceCMN-CMGPV
MachinePET / HP
PowerDual drives — preserve separate motor cells
Working pressureConfiguration bands2.0–3.0 or2.0–4.0 MPa
Published flowCM130GPV:5.4–13.5 or4.0–10.2 m³/min;bands differ
Air quality—
DutyPET / blowing
SupplyNot specified
PlantCMN / Xinmaien Technology (Taizhou)
ArrangementWater-lubricated oil-free screw;two-stage dual-drive PM VSD
CM75GPV2.0–3.0MPa;2.5–6.3m³/min;separate motor cells30 /45kW
CM75GPV installation18T/h water;DN32;2000 × 1900 × 1480mm;2250kg
CM100GPV2.0–4.0MPa;3.3–8.2m³/min;separate motor cells55 /55kW
CM100GPV installation21T/h water;DN32;2500 × 2000 × 1550mm;2450kg
CM130GPV entry12.0–3.0MPa;5.4–13.5m³/min
CM130GPV entry22.0–4.0MPa;4.0–10.2m³/min
CM130GPV both55 /75kW separate cells;35T/h water;DN32;2500 × 2000 × 1550mm;3000kg
CM242GPV2.0–4.0MPa;9.6–24.0m³/min;110 /132kW separate cells
CM242GPV installation50T/h water;DN40;2760 × 2250 × 1670mm;3950kg
ScopeIntervals are not guaranteed paired maximum-pressure/maximum-flow points
Power/flowIndividual drives,package input and exact pressure curve to obtain

Plant

CMN / Xinmaien Technology (Taizhou)

Taizhou

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a PET / HP duty

All spec pages
DutyWrite on the RFQ
30 bar oil-free compressor Specify whether 30 bar is gauge or absolute pressure, where it is required and how much air must be supplied at that point. A 30 bar working duty does not, by itself, identify a compressor architecture, motor size or air-quality class.
Compressor for PET bottle blowing Bottle blowing is a high-pressure oil-free process. The blower OEM’s pressure and the cavity count size the compressor, not the word PET.
40 bar PET compressor PET blowing at 40 bar(g) is a high-pressure oil-free duty. Cavities, bottle volume and recovery pressure size the skid — not the word “PET compressor”.

Same type

Related PET / HP products

Compare the published product information for each manufacturer.

Full PET / HP list
Catalog ref.TypePowerPressureFlowAir qualityPlant
UNIGY-PET-OILFREE UNIGY oil-free reciprocating PET air and booster packages UNIGY-PET-OILFREEUNIGY oil-free reciprocating PET air and booster packages PET / HP Exact selected motor / package input 0.7–5.0 MPa — published envelope 0.1–20 m³/min — reference required — UNIGY — Luoyang industrial gas compressors RFQ
DMG-DOLPHIN DMG Dolphin water-lubricated screw / piston PET systems DMG-DOLPHINDMG Dolphin water-lubricated screw / piston PET systems PET / HP OGV-6:67 kW installed /60 kW shaft Selected table duties:4.0 MPa OGV-6:6.0 Nm³/min; normal reference to agree — DMG RFQ
ZDHS-G0-G2 Zhongding G0–G2 diaphragm compressors for compact and process-gas duties ZDHS-G0-G2Zhongding G0–G2 diaphragm compressors for compact and process-gas duties PET / HP — — — — Zhongding RFQ
BAODE-LASERB&D BD-TK laser-cutting air packages, pressure-specific variants PET / HP 15 / 22 kW · selected detail rows 1.5 / 2.5 / 3 MPa · selected variant BD-PM22TK: 0.88–2.2 m³/min · 1.5 MPa version — B&D RFQ
DMG-EAGLE DMG Eagle four-stage screw / piston PET systems DMG-EAGLEDMG Eagle four-stage screw / piston PET systems PET / HP 16 Nm³/min models:145 installed /131 shaft kW Selected table duties:4.0 MPa LGV2/LGW2 points:6–30 Nm³/min — DMG RFQ
HTXD-LASER Huitong Xinda laser-cutting screw — HD pressure and treatment interface HTXD-LASERHuitong Xinda laser-cutting screw — HD pressure and treatment interface PET / HP HD model rows:11/15/22 kW 1.3 or 1.6 MPa by model HD-11:1.4 or 1.2 m³/min respectively — Huitong Xinda RFQ

CMN-CMGPV: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ