PET / HP
Zhongding G0–G2 diaphragm compressors for compact and process-gas duties — Zhongding Hengsheng (Wuhu)
Zhongding G0–G2 diaphragm compressors for compact and process-gas duties · Zhongding Hengsheng (Wuhu)
Datasheet
Product overview
Zhongding G0–G2 diaphragm compressors for compact and process-gas duties from Zhongding Hengsheng (Wuhu)
Zhongding's G0, G1 and G2 diaphragm families cover distinct small and medium configurations. The G0 page describes P/D layouts, air- or water-cooled options and splash lubrication of the drive; G1 lists Z/L layouts, while G2 lists Z/L/P/D configurations and forced lubrication. Drive lubrication is not a blanket gas-purity certification. Obtain the actual gas-side materials, diaphragm and contamination requirements for the offered model.
The G0 table lists GZ0-2/0.6-10 at 2 Nm³/h with 0.06 MPa(g) inlet and 1 MPa(g) outlet, 750 rpm, 1.5 kW motor, 1000 × 600 × 870 mm and 300 kg. A separate GZ0-26/180-200 point is 26 Nm³/h with 18 MPa(g) inlet and 20 MPa(g) outlet, 300 L/h cooling water, 750 rpm, 1.5 kW, 1200 × 780 × 1050 mm and 450 kg. The same motor rating does not make the flow or pressure conditions interchangeable.
Keep normal-volume flow and gauge pressure explicit. Ask for reference temperature/pressure, actual gas composition, minimum and maximum inlet conditions, permissible inlet temperature and operation across the required load range. Do not apply either G0 point to G1 or G2 without a named-model proposal.
The G0 maintenance description calls for at least 1 m around the machine and a 60–70 kg component lifting provision. G1 describes a 70–80 kg maintenance component; G2 describes approximately 100 kg. Obtain the actual service drawing, lifting and access procedure for the ordered configuration.
The original G2 photo accompanies a manufacturer-reported 2026 hydrogen/ammonia-mixture project. Its reported 220°C inlet condition is specific to that engineered project, not a general rating of the G0–G2 range. Request material/seal, diaphragm, purity and hazard review for a hot or mixed-gas duty.
An RFQ should include gas composition and impurities, inlet/outlet pressure and temperature envelopes, flow basis and duty cycle, cooling, electrical supply, area classification and controls. Agree the quoted configuration, protections and diaphragm leak monitoring, test medium/conditions, documents, spare parts and startup scope.
| Catalog reference | ZDHS-G0-G2 |
|---|---|
| Machine | PET / HP |
| Power | — |
| Working pressure | — |
| Published flow | — |
| Air quality | — |
| Duty | Energy / gas |
| Supply | Not specified |
| Plant | Zhongding Hengsheng (Wuhu) |
| Flow basis | Nm³/h; obtain normal reference temperature/pressure |
| Pressure basis | MPa(g), gauge |
| GZ0-2/0.6-10 | 2 Nm³/h; inlet 0.06 → outlet 1 MPa(g); 1.5 kW; 750 rpm |
| GZ0-2 envelope / mass | 1000 × 600 × 870 mm; 300 kg |
| GZ0-26/180-200 | 26 Nm³/h; inlet 18 → outlet 20 MPa(g); 1.5 kW; 750 rpm; water 300 L/h |
| GZ0-26 envelope / mass | 1200 × 780 × 1050 mm; 450 kg |
| G0 maintenance provision | At least 1 m around machine; 60–70 kg component |
| Scope | G1/G2 require separate named-model gas and duty selection |
Plant
Zhongding Hengsheng (Wuhu)
Wuhu
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
Specification pages
Specifying a PET / HP duty
| Duty | Write on the RFQ |
|---|---|
| 30 bar oil-free compressor | Specify whether 30 bar is gauge or absolute pressure, where it is required and how much air must be supplied at that point. A 30 bar working duty does not, by itself, identify a compressor architecture, motor size or air-quality class. |
| 40 bar PET compressor | PET blowing at 40 bar(g) is a high-pressure oil-free duty. Cavities, bottle volume and recovery pressure size the skid — not the word “PET compressor”. |
| Compressor for PET bottle blowing | Bottle blowing is a high-pressure oil-free process. The blower OEM’s pressure and the cavity count size the compressor, not the word PET. |
Same type
Related PET / HP products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
UNIGY-PET-OILFREEUNIGY oil-free reciprocating PET air and booster packages
|
PET / HP | Exact selected motor / package input | 0.7–5.0 MPa — published envelope | 0.1–20 m³/min — reference required | — | UNIGY — Luoyang industrial gas compressors | RFQ |
DMG-DOLPHINDMG Dolphin water-lubricated screw / piston PET systems
|
PET / HP | OGV-6:67 kW installed /60 kW shaft | Selected table duties:4.0 MPa | OGV-6:6.0 Nm³/min; normal reference to agree | — | DMG | RFQ |
| BAODE-LASERB&D BD-TK laser-cutting air packages, pressure-specific variants | PET / HP | 15 / 22 kW · selected detail rows | 1.5 / 2.5 / 3 MPa · selected variant | BD-PM22TK: 0.88–2.2 m³/min · 1.5 MPa version | — | B&D | RFQ |
CMN-CMGPVCMN CM/GPV medium-pressure oil-free screw — dual-drive configurations
|
PET / HP | Dual drives — preserve separate motor cells | Configuration bands2.0–3.0 or2.0–4.0 MPa | CM130GPV:5.4–13.5 or4.0–10.2 m³/min;bands differ | — | CMN | RFQ |
DMG-EAGLEDMG Eagle four-stage screw / piston PET systems
|
PET / HP | 16 Nm³/min models:145 installed /131 shaft kW | Selected table duties:4.0 MPa | LGV2/LGW2 points:6–30 Nm³/min | — | DMG | RFQ |
HTXD-LASERHuitong Xinda laser-cutting screw — HD pressure and treatment interface
|
PET / HP | HD model rows:11/15/22 kW | 1.3 or 1.6 MPa by model | HD-11:1.4 or 1.2 m³/min respectively | — | Huitong Xinda | RFQ |
ZDHS-G0-G2: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.