PET / HP

Zhongding G0–G2 diaphragm compressors for compact and process-gas duties — Zhongding Hengsheng (Wuhu)

Zhongding G0–G2 diaphragm compressors for compact and process-gas duties · Zhongding Hengsheng (Wuhu)

Zhongding G0–G2 diaphragm compressors for compact and process-gas duties — official catalog illustration
Zhongding G0–G2 diaphragm compressors for compact and process-gas duties — manufacturer catalog illustration

Datasheet

Product overview

Zhongding G0–G2 diaphragm compressors for compact and process-gas duties from Zhongding Hengsheng (Wuhu)

Zhongding's G0, G1 and G2 diaphragm families cover distinct small and medium configurations. The G0 page describes P/D layouts, air- or water-cooled options and splash lubrication of the drive; G1 lists Z/L layouts, while G2 lists Z/L/P/D configurations and forced lubrication. Drive lubrication is not a blanket gas-purity certification. Obtain the actual gas-side materials, diaphragm and contamination requirements for the offered model.

The G0 table lists GZ0-2/0.6-10 at 2 Nm³/h with 0.06 MPa(g) inlet and 1 MPa(g) outlet, 750 rpm, 1.5 kW motor, 1000 × 600 × 870 mm and 300 kg. A separate GZ0-26/180-200 point is 26 Nm³/h with 18 MPa(g) inlet and 20 MPa(g) outlet, 300 L/h cooling water, 750 rpm, 1.5 kW, 1200 × 780 × 1050 mm and 450 kg. The same motor rating does not make the flow or pressure conditions interchangeable.

Keep normal-volume flow and gauge pressure explicit. Ask for reference temperature/pressure, actual gas composition, minimum and maximum inlet conditions, permissible inlet temperature and operation across the required load range. Do not apply either G0 point to G1 or G2 without a named-model proposal.

The G0 maintenance description calls for at least 1 m around the machine and a 60–70 kg component lifting provision. G1 describes a 70–80 kg maintenance component; G2 describes approximately 100 kg. Obtain the actual service drawing, lifting and access procedure for the ordered configuration.

The original G2 photo accompanies a manufacturer-reported 2026 hydrogen/ammonia-mixture project. Its reported 220°C inlet condition is specific to that engineered project, not a general rating of the G0–G2 range. Request material/seal, diaphragm, purity and hazard review for a hot or mixed-gas duty.

An RFQ should include gas composition and impurities, inlet/outlet pressure and temperature envelopes, flow basis and duty cycle, cooling, electrical supply, area classification and controls. Agree the quoted configuration, protections and diaphragm leak monitoring, test medium/conditions, documents, spare parts and startup scope.

Catalog referenceZDHS-G0-G2
MachinePET / HP
Power—
Working pressure—
Published flow—
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantZhongding Hengsheng (Wuhu)
Flow basisNm³/h; obtain normal reference temperature/pressure
Pressure basisMPa(g), gauge
GZ0-2/0.6-102 Nm³/h; inlet 0.06 → outlet 1 MPa(g); 1.5 kW; 750 rpm
GZ0-2 envelope / mass1000 × 600 × 870 mm; 300 kg
GZ0-26/180-20026 Nm³/h; inlet 18 → outlet 20 MPa(g); 1.5 kW; 750 rpm; water 300 L/h
GZ0-26 envelope / mass1200 × 780 × 1050 mm; 450 kg
G0 maintenance provisionAt least 1 m around machine; 60–70 kg component
ScopeG1/G2 require separate named-model gas and duty selection

Plant

Zhongding Hengsheng (Wuhu)

Wuhu

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a PET / HP duty

All spec pages
DutyWrite on the RFQ
30 bar oil-free compressor Specify whether 30 bar is gauge or absolute pressure, where it is required and how much air must be supplied at that point. A 30 bar working duty does not, by itself, identify a compressor architecture, motor size or air-quality class.
40 bar PET compressor PET blowing at 40 bar(g) is a high-pressure oil-free duty. Cavities, bottle volume and recovery pressure size the skid — not the word “PET compressor”.
Compressor for PET bottle blowing Bottle blowing is a high-pressure oil-free process. The blower OEM’s pressure and the cavity count size the compressor, not the word PET.

Same type

Related PET / HP products

Compare the published product information for each manufacturer.

Full PET / HP list
Catalog ref.TypePowerPressureFlowAir qualityPlant
UNIGY-PET-OILFREE UNIGY oil-free reciprocating PET air and booster packages UNIGY-PET-OILFREEUNIGY oil-free reciprocating PET air and booster packages PET / HP Exact selected motor / package input 0.7–5.0 MPa — published envelope 0.1–20 m³/min — reference required — UNIGY — Luoyang industrial gas compressors RFQ
DMG-DOLPHIN DMG Dolphin water-lubricated screw / piston PET systems DMG-DOLPHINDMG Dolphin water-lubricated screw / piston PET systems PET / HP OGV-6:67 kW installed /60 kW shaft Selected table duties:4.0 MPa OGV-6:6.0 Nm³/min; normal reference to agree — DMG RFQ
BAODE-LASERB&D BD-TK laser-cutting air packages, pressure-specific variants PET / HP 15 / 22 kW · selected detail rows 1.5 / 2.5 / 3 MPa · selected variant BD-PM22TK: 0.88–2.2 m³/min · 1.5 MPa version — B&D RFQ
CMN-CMGPV CMN CM/GPV medium-pressure oil-free screw — dual-drive configurations CMN-CMGPVCMN CM/GPV medium-pressure oil-free screw — dual-drive configurations PET / HP Dual drives — preserve separate motor cells Configuration bands2.0–3.0 or2.0–4.0 MPa CM130GPV:5.4–13.5 or4.0–10.2 m³/min;bands differ — CMN RFQ
DMG-EAGLE DMG Eagle four-stage screw / piston PET systems DMG-EAGLEDMG Eagle four-stage screw / piston PET systems PET / HP 16 Nm³/min models:145 installed /131 shaft kW Selected table duties:4.0 MPa LGV2/LGW2 points:6–30 Nm³/min — DMG RFQ
HTXD-LASER Huitong Xinda laser-cutting screw — HD pressure and treatment interface HTXD-LASERHuitong Xinda laser-cutting screw — HD pressure and treatment interface PET / HP HD model rows:11/15/22 kW 1.3 or 1.6 MPa by model HD-11:1.4 or 1.2 m³/min respectively — Huitong Xinda RFQ

ZDHS-G0-G2: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ