PET / HP

Zhongding G5 large diaphragm compressors: 750 Nm³/h inlet-pressure comparison — Zhongding Hengsheng (Wuhu)

Zhongding G5 large diaphragm compressors: 750 Nm³/h inlet-pressure comparison · Zhongding Hengsheng (Wuhu)

Zhongding G5 large diaphragm compressors: 750 Nm³/h inlet-pressure comparison — official catalog illustration
Zhongding G5 large diaphragm compressors: 750 Nm³/h inlet-pressure comparison — manufacturer catalog illustration

Datasheet

Product overview

Zhongding G5 large diaphragm compressors: 750 Nm³/h inlet-pressure comparison from Zhongding Hengsheng (Wuhu)

The Zhongding G5 catalogue describes a large D-layout diaphragm platform with two-, three-, four- or six-cylinder configurations, water cooling, forced lubrication and oil-replenishment arrangements. The actual cylinder/stage arrangement and gas duty belong in the named-model proposal.

Two published G5 records illustrate why inlet pressure must accompany the delivery figure. GD5-750/6-210 lists 750 Nm³/h with 0.6 MPa(g) inlet and 21 MPa(g) outlet, 12,000 L/h cooling water, 420 rpm and 160 kW motor power. Its envelope is 4300 × 3200 × 2200 mm and its listed weight is 16,000 kg.

GD5-750/15-210 lists the same 750 Nm³/h and 21 MPa(g) outlet, but 1.5 MPa(g) inlet, 10,000 L/h cooling water, 420 rpm and 110 kW motor power. It has the same published envelope and 14,000 kg listed weight. These are separate reference models. Do not apply the lower motor/cooling values to the lower-inlet-pressure duty or claim a guaranteed operating range from the two rows.

Keep MPa(g) as gauge pressure and Nm³/h as normal-volume flow. Agree the normal temperature/pressure, actual gas, minimum/normal/maximum inlet pressure and temperature, suction supply variation and the required discharge/control behavior. Obtain selected-duty performance and package electrical data rather than equating motor rating with total electrical input.

G5's maintenance description requires at least 2.5 m around the machine and provision to lift a maintenance component of approximately 5000 kg. This is separate from the 14–16 tonne whole-machine weights of these two references. Agree the final foundation, floor loads, crane/rigging arrangement, service clearances and access path using current project drawings.

The original G5 catalogue image is a manufacturer illustration. Request actual configured-unit images, current drawings and agreed inspection records for the offered equipment. Specify cooling-water inlet conditions, controls, diaphragm leak monitoring, gas/hazard compatibility, safeguards, test medium and acceptance conditions, spares and commissioning scope. A filling requirement expressed only as daily kilograms is not sufficient to choose this compressor without inlet/outlet conditions and the actual hourly gas duty.

Catalog referenceZDHS-G5
MachinePET / HP
Power—
Working pressure—
Published flow—
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantZhongding Hengsheng (Wuhu)
Both references750 Nm³/h; outlet 21 MPa(g); 420 rpm; normal reference conditions to agree
GD5-750/6-210Inlet 0.6 MPa(g); motor 160 kW; water 12,000 L/h; 16,000 kg
GD5-750/15-210Inlet 1.5 MPa(g); motor 110 kW; water 10,000 L/h; 14,000 kg
Both published envelopes4300 × 3200 × 2200 mm
G5 maintenance provisionAt least 2.5 m around machine; approximately 5000 kg component lifting
ConditionsActual gas, inlet variation/temperature, cooling-water conditions and total package data
InterpretationSeparate named points; not a guaranteed single-machine operating range

Plant

Zhongding Hengsheng (Wuhu)

Wuhu

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a PET / HP duty

All spec pages
DutyWrite on the RFQ
40 bar PET compressor PET blowing at 40 bar(g) is a high-pressure oil-free duty. Cavities, bottle volume and recovery pressure size the skid — not the word “PET compressor”.
Compressor for PET bottle blowing Bottle blowing is a high-pressure oil-free process. The blower OEM’s pressure and the cavity count size the compressor, not the word PET.
30 bar oil-free compressor Specify whether 30 bar is gauge or absolute pressure, where it is required and how much air must be supplied at that point. A 30 bar working duty does not, by itself, identify a compressor architecture, motor size or air-quality class.

Same type

Related PET / HP products

Compare the published product information for each manufacturer.

Full PET / HP list
Catalog ref.TypePowerPressureFlowAir qualityPlant
UNIGY-PET-OILFREE UNIGY oil-free reciprocating PET air and booster packages UNIGY-PET-OILFREEUNIGY oil-free reciprocating PET air and booster packages PET / HP Exact selected motor / package input 0.7–5.0 MPa — published envelope 0.1–20 m³/min — reference required — UNIGY — Luoyang industrial gas compressors RFQ
DMG-DOLPHIN DMG Dolphin water-lubricated screw / piston PET systems DMG-DOLPHINDMG Dolphin water-lubricated screw / piston PET systems PET / HP OGV-6:67 kW installed /60 kW shaft Selected table duties:4.0 MPa OGV-6:6.0 Nm³/min; normal reference to agree — DMG RFQ
ZDHS-G0-G2 Zhongding G0–G2 diaphragm compressors for compact and process-gas duties ZDHS-G0-G2Zhongding G0–G2 diaphragm compressors for compact and process-gas duties PET / HP — — — — Zhongding RFQ
BAODE-LASERB&D BD-TK laser-cutting air packages, pressure-specific variants PET / HP 15 / 22 kW · selected detail rows 1.5 / 2.5 / 3 MPa · selected variant BD-PM22TK: 0.88–2.2 m³/min · 1.5 MPa version — B&D RFQ
CMN-CMGPV CMN CM/GPV medium-pressure oil-free screw — dual-drive configurations CMN-CMGPVCMN CM/GPV medium-pressure oil-free screw — dual-drive configurations PET / HP Dual drives — preserve separate motor cells Configuration bands2.0–3.0 or2.0–4.0 MPa CM130GPV:5.4–13.5 or4.0–10.2 m³/min;bands differ — CMN RFQ
DMG-EAGLE DMG Eagle four-stage screw / piston PET systems DMG-EAGLEDMG Eagle four-stage screw / piston PET systems PET / HP 16 Nm³/min models:145 installed /131 shaft kW Selected table duties:4.0 MPa LGV2/LGW2 points:6–30 Nm³/min — DMG RFQ

ZDHS-G5: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ