Zhongding G3–G4 diaphragm compressors with named gas-duty references from Zhongding Hengsheng (Wuhu)

Zhongding describes G3 as a medium diaphragm family with Z/L/V/P/D configurations and air- or water-cooling routes. G4 is a compact D-layout medium family with two-, three- or four-cylinder arrangements and water cooling. Both describe forced drive lubrication. Select the actual cylinder/stage configuration against gas medium and inlet/outlet conditions; do not infer configuration solely from an aggregated family title.

A G3 reference, GZ3-50/10-150, lists 50 Nm³/h with 1 MPa(g) inlet and 15 MPa(g) outlet, 1000 L/h cooling water, 400 rpm, 11 kW motor, 2400 × 1400 × 2000 mm and 3500 kg. A separate G4 reference, GD4-200/15-350, lists 200 Nm³/h with 1.5 MPa(g) inlet and 35 MPa(g) outlet, 4600 L/h cooling water, 360 rpm, 55 kW motor, 3800 × 2600 × 1800 mm and 9000 kg. These are named table rows with different conditions, not a common range valid for every gas.

Normal-volume flow requires its reference temperature and pressure; MPa(g) is the table's gauge-pressure basis. Request performance and power at minimum/normal/maximum suction conditions, along with allowable inlet temperature, gas compatibility and required control range. A motor nameplate value is separate from package input, cooling performance or guaranteed gas purity.

G4's maintenance description calls for at least 1.5 m around the machine and lifting a component of approximately 1000 kg. Whole-machine weight for the selected GD4 reference is separately 9000 kg. Include service access, lifting route, overhead clearance and foundation requirements in the installation review.

The corresponding original G3/G4 images are manufacturer illustrations, not photographs of an offered serial-numbered machine. Request current arrangement drawings and an actual configured-unit inspection when the purchase scope calls for it.

For a process or hydrogen proposal, give actual gas/impurities, inlet and outlet conditions, flow basis, cooling-water availability and electrical/hazardous-area requirements. Agree material/diaphragm specifications, leak/protection functions, controls integration, acceptance-test conditions, parts, startup responsibilities and applicable destination documents.

Catalog referenceZDHS-G3-G4
MachinePET / HP
Power—
Working pressure—
Published flow—
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantZhongding Hengsheng (Wuhu)
Pressure basisMPa(g); flow basis Nm³/h, normal reference to agree
GZ3-50/10-15050 Nm³/h; inlet 1 → outlet 15 MPa(g); 11 kW; 400 rpm
GZ3 cooling / envelope / mass1000 L/h; 2400 × 1400 × 2000 mm; 3500 kg
GD4-200/15-350200 Nm³/h; inlet 1.5 → outlet 35 MPa(g); 55 kW; 360 rpm
GD4 cooling / envelope / mass4600 L/h; 3800 × 2600 × 1800 mm; 9000 kg
G4 maintenance provisionAt least 1.5 m around machine; approximately 1000 kg component lifting
Purchase conditionsActual gas, inlet-temperature envelope, cooling and protection review

Plant

Zhongding Hengsheng (Wuhu)

Wuhu

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a PET / HP duty

All spec pages
DutyWrite on the RFQ
40 bar PET compressor PET blowing at 40 bar(g) is a high-pressure oil-free duty. Cavities, bottle volume and recovery pressure size the skid — not the word “PET compressor”.
Compressor for PET bottle blowing Bottle blowing is a high-pressure oil-free process. The blower OEM’s pressure and the cavity count size the compressor, not the word PET.
30 bar oil-free compressor Specify whether 30 bar is gauge or absolute pressure, where it is required and how much air must be supplied at that point. A 30 bar working duty does not, by itself, identify a compressor architecture, motor size or air-quality class.

Same type

Related PET / HP products

Compare the published product information for each manufacturer.

Full PET / HP list
Catalog ref.TypePowerPressureFlowAir qualityPlant
UNIGY-PET-OILFREE UNIGY oil-free reciprocating PET air and booster packages UNIGY-PET-OILFREEUNIGY oil-free reciprocating PET air and booster packages PET / HP Exact selected motor / package input 0.7–5.0 MPa — published envelope 0.1–20 m³/min — reference required — UNIGY — Luoyang industrial gas compressors RFQ
DMG-DOLPHIN DMG Dolphin water-lubricated screw / piston PET systems DMG-DOLPHINDMG Dolphin water-lubricated screw / piston PET systems PET / HP OGV-6:67 kW installed /60 kW shaft Selected table duties:4.0 MPa OGV-6:6.0 Nm³/min; normal reference to agree — DMG RFQ
ZDHS-G0-G2 Zhongding G0–G2 diaphragm compressors for compact and process-gas duties ZDHS-G0-G2Zhongding G0–G2 diaphragm compressors for compact and process-gas duties PET / HP — — — — Zhongding RFQ
BAODE-LASERB&D BD-TK laser-cutting air packages, pressure-specific variants PET / HP 15 / 22 kW · selected detail rows 1.5 / 2.5 / 3 MPa · selected variant BD-PM22TK: 0.88–2.2 m³/min · 1.5 MPa version — B&D RFQ
CMN-CMGPV CMN CM/GPV medium-pressure oil-free screw — dual-drive configurations CMN-CMGPVCMN CM/GPV medium-pressure oil-free screw — dual-drive configurations PET / HP Dual drives — preserve separate motor cells Configuration bands2.0–3.0 or2.0–4.0 MPa CM130GPV:5.4–13.5 or4.0–10.2 m³/min;bands differ — CMN RFQ
DMG-EAGLE DMG Eagle four-stage screw / piston PET systems DMG-EAGLEDMG Eagle four-stage screw / piston PET systems PET / HP 16 Nm³/min models:145 installed /131 shaft kW Selected table duties:4.0 MPa LGV2/LGW2 points:6–30 Nm³/min — DMG RFQ

ZDHS-G3-G4: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.