DCO15-8
- Package rating
- 11 kW
- Flow at 8 bar
- 1.30 m³/min
- Cabinet
- 1670 × 680 × 1698 mm
- Outlet / mass
- G3/4 · 360 kg
Qidong
Compare stage arrangements at the same pressure, or define a scroll package by its modules and service requirements.

DEHAHA / DHH · QIDONG, NANTONG
德哈哈压缩机江苏有限公司 is the Jiangsu compressor company identified by Dehaha’s site, with its operation in Qidong Economic Development Zone. The site separately lists a Shanghai company and office. Align the contracting company, actual manufacturing address and equipment documents in the offer.
The company describes industrial air-compressor development and manufacturing, including screw, oil-free and air-treatment equipment. Its historical account places a Qidong base expansion in 2004; that statement does not establish the present legal entity’s incorporation date.

CPM SINGLE STAGE · CPDM TWO STAGE


The CP product material has separate single-stage CPM and two-stage CPDM sheets. The single-stage description names an integrated shaft arrangement, LCD display and PID pressure control. The comparison below keeps pressure fixed instead of combining the family’s largest flow with a different pressure.
| Selection | Flow at 0.8 MPa | Enclosure / mass | Outlet |
|---|---|---|---|
| CP75M · single stage | 12.80 m³/min | 1750 × 1272 × 1560 mm 1120 kg | G2 |
| CP75DM · two stage | 15.5 m³/min | 2100 × 1433 × 1590 mm 1700 kg | G2 |
CP22M publishes 3.70 / 3.60 / 3.20 / 2.80 m³/min at 0.7 / 0.8 / 1.0 / 1.3 MPa. Its 22 kW rating, G1 outlet, 1140 × 780 × 1210 mm enclosure and 370 kg mass belong to that specific row.
The two-stage CP75DM row gives 16.0 / 15.5 / 12.8 / 10.2 m³/min at the same four pressure columns. These are published selection points, not measured annual savings. Obtain the complete volume reference, pressure basis, actual package input and part-load/control behavior at your site’s demand.
DCO OIL-FREE SCROLL · MODULAR ENCLOSURES

The detailed DCO diagram shows fixed and orbiting scroll elements compressing pockets of air toward a central discharge. Larger cabinets combine several airends with staged control.
DCO15-8 is 11 kW, not 15 kW. The model name is separate from installed motor power. All selected rows below publish their flow at 8 bar; the full volume reference and pressure basis should accompany the offered performance sheet.
Provide sustained and peak flow and the acceptable interruption during service. Ask how modules start/stop, share running hours and respond to an isolated module. Obtain the available package capacity under that condition; do not assume proportional certified output from module count alone.
Cabinet size is not module-removal or cooling clearance. Agree the installation/service drawing, ambient limit and supply. Define moisture, particles and oil at the process connection, dryer/filter scope, drains and sampling tests. Oil-free compression alone does not establish food, medical or breathing-air approval.
COMPANY CONTEXT · MODEL-SPECIFIC OFFER
The 2022 national recommended catalogue of energy-saving equipment names 德哈哈压缩机江苏有限公司 and model DHH75DM-8. It independently identifies the company and a historical listed model. It is not a current certificate for CP75DM or the full CPM and DCO ranges. Ask the manufacturer to explain differently prefixed names rather than merging their ratings.
Full offered model, CPM/CPDM stage arrangement or DCO module count, pressure-matched flow with reference conditions, input power and speed/staging behavior across your load cycle.
Electrical supply, ventilation/heat rejection, service and module-removal access, piping and outlet interfaces, receiver/dryer/filter scope and process air-quality acceptance.
Contracting company and manufacturing address, agreed inspection records, current issuer and model scope for any required certificate, drawings, manuals, wear-parts intervals and destination documents. Put commissioning and support responsibility in the offer.
The two published flows share a pressure column, but motor rating alone is not measured package input. Obtain the same flow/test reference, actual input and part-load results for the proposed duty before comparing operating cost.
Module count establishes its arrangement, not guaranteed output during a fault or maintenance. Specify required service capacity and ask for the actual isolation, sequencing and protection behavior.
The names differ. Obtain the manufacturer’s model relationship and current documents scoped to the actual offered machine; keep the historical listing separate.
Send the chosen stage or module arrangement, pressure/flow reference, demand cycle and process air requirements.
Specify the Dehaha dutySpecification pages
| Duty | Write on the RFQ |
|---|---|
| How to specify an air compressor | If the RFQ only says “compressor, China”, a plant cannot price it. Start with architecture, then the duty point, then the papers. |
| 75 kW 8 bar rotary screw compressor | 75 kW at 8 bar(g) is a common plant-air point. FAD is not a brochure range — it is the flow at that pressure, after the cooler, for the voltage you actually run. |
| 110 kW 10 bar rotary screw compressor | 10 bar(g) is not 8 bar with a different sticker. FAD falls as pressure rises. Write 110 kW and 10 bar together, then the flow you need at that point. |
| 22 kW VSD screw compressor | 22 kW VSD is a flow band, not a single nameplate FAD. The plant needs min/max flow at the working pressure, or it will quote a fixed-speed machine with an inverter sticker. |
Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
Dehaha: Compare stage arrangements at the same pressure, or define a scroll package by its modules and service requirements.
Open RFQ