OUTSTANDING · 奥突斯 · Shitang, Wenling
Receiver-mounted air packages from a Wenling compressor manufacturer
The official English identity is Taizhou Outstanding Industry and Trade; its Chinese company name is 台州市奥突斯工贸有限公司. The catalog separates oil-free and oil-lubricated lines under the OUTSTANDING brand.
The manufacturer describes development, production and inspection equipment in Wenling's Shangma industrial area. Its original gallery shows machining/manufacturing stations, assembly lines and receiver-mounted equipment.


Connect the order to its inspection records
Agree the actual assembly and inspection arrangements, model/serial identification, receiver records and electrical/compressor tests for the supplied package. Gallery photographs show published production activity; an order's acceptance needs its own documents.
OTS multi-unit oil-free series
Two receiver packages with different speed, mass and air-volume entries

OTS-1600×4-160L
The page lists 6,000 W, 1,380 rpm and a 160 L receiver. The model label's digits should not replace the manufacturer's actual parameter row.
The separate two-pole 1250×4-120L entry lists 3,000 W, 2,800 rpm and a 120 L receiver. “Two pole” is not a statement of two-stage compression.
Match the proposed package to demand, working cycle and installation space; receiver size alone does not settle usable delivery.
| Parameter | OTS-1600×4-160L | Two-pole 1250×4-120L |
|---|---|---|
| Power / speed | 6,000 W / 1,380 rpm | 3,000 W / 2,800 rpm |
| Pressure / air volume | 7.0 bar / 400 L/min | 7.0 bar / 180 L/min |
| Receiver / mass | 160 L / 131 kg | 120 L / 71 kg |
| L × W × H | 144 × 55 × 99 cm | 127 × 48 × 82 cm |
Oil-lubricated series · 40 L premium V-type twin-cylinder
A compact V-twin has a different lubrication and duty discussion
- Published power / speed
- 1,800 W / 2,850 rpm
- Pressure / air volume
- 8.0 bar / 120 L/min
- Receiver / mass
- 40 L / 29 kg
- Dimensions L × W × H
- 67 × 37 × 64 cm
The catalog classifies this unit in the oil-lubricated line. The V layout and twin cylinders do not establish two-stage compression.
Confirm lubrication and maintenance, selected supply/starting current and the permitted working/recovery cycle. Obtain usable delivery for the actual tool or process rather than selecting only by the 40 L label.
40 L V-twin and order conditions →
For intermittent tools, spraying or another small-air duty
Write the working cycle before choosing the tank
Tool or process demand
Attach the user's required pressure, consumption and oil/moisture/particle limits. Include hoses, filters and losses between receiver and user.
On-time and recovery
Describe continuous runs, short bursts, pauses and shifts. Request the selected model's permitted duty and recovery cycle at site conditions.
Starting and controls
For a multi-unit package, establish motor/pump start/stop sequence, any staggered starting and actual electrical protection.
Put the site conditions on the offer
- Actual voltage, frequency, phase, current and starting requirements.
- Ventilation, ambient limits, service clearance and maintenance access.
- Noise measurement conditions for the selected machine.
- Regulator, drying, filtration, drains and delivered-quality scope.
An oil-free category does not define a complete quality class or medical-air approval. Specify the point of use and applicable selected-model documents.
The receiver and support scope are part of the order
Identify the actual receiver
Obtain receiver identification, working limits and applicable manufacture/test documents. Agree the drain, safety valve and pressure-control settings for the destination.
Agree the delivery records
Connect the full model and serial identification to receiver, electrical and compressor inspection records. Request the operating/maintenance manual, consumables and spare identifiers.
Assign commissioning and service
Outstanding describes selection, pre-dispatch inspection, installation guidance, maintenance training and original spare support. Agree what is included, who supports the destination and the actual warranty/spare lead times.
Send a defined receiver-package requirement
Choose oil-free or the oil-lubricated V-twin, then attach user demand, working cycle, supply and receiver/document requirements.
Prepare an Outstanding OTS enquiry →Outstanding OTS selection questions
Is OTS-1600×4 rated by multiplying 1,600 by four?
Its published parameter row lists 6,000 W. Use that row and the offered model's electrical documents; model labels are not a substitute for total input, current or supply requirements.
Is “two pole” a two-stage compressor?
The catalog's two-pole 1250×4 designation should not be treated as a two-stage compression statement. Request the actual construction and operating documentation for the proposed unit.
Can the 160 L receiver supply continuous 400 L/min tool demand?
The source lists air volume 400 L/min without a FAD/reference basis or full duty envelope. Establish usable delivery at user pressure and the permitted working/recovery cycle, including losses. Receiver volume alone does not establish continuous capacity.
Does the oil-free line include drying and process-air certification?
Define oil, moisture and particle limits at the actual user, then agree treatment and applicable model documents. The catalog category does not establish an included dryer, complete quality class or medical-air approval.