浙江盛源空压机制造有限公司 · Zeguo, Wenling
Choose an air package, an instrument supply or an onboard assembly
Zhejiang Shengyuan Air Compressor Manufacturing Co., Ltd. uses the SUNSOURCE brand. Its company profile dates the business to 2005 and identifies Wenling, Zhejiang as its headquarters. The catalog includes water-lubricated screw equipment, industrial oil-free compressors, research-use cabinets, vacuum pumps and electric-vehicle applications.

What to ask about the manufacturing and test scope
The company publishes machining-workshop, test-bench and inspection-equipment photographs. Put the selected model, production/inspection location and acceptance procedure on the purchase documents.
The national standards platform also names Zhejiang Shengyuan among drafting organizations for a vacuum-pump performance measurement standard plan. That role corroborates company identity; it does not certify these air-compressor models.
First distinction: vacuum suction, instrument air and vehicle pressure supply need different duty descriptions.
Water-lubricated screw route · A08075W / A0815w
Define the water circuit alongside the air duty

The manufacturer identifies A08075W and A0815w in its water-lubricated oil-free screw catalog. Obtain the current model/version selection sheet and arrangement drawing.
- Air duty
- Pressure at the users; minimum, normal and peak delivery; operating hours and flow reference conditions.
- Water and cooling
- Water quality/source, replenishment, drainage, cooling connections and service procedure.
- Complete package
- Electrical supply, input power, controls, treatment and service clearances.
SY industrial presentation · Oil-free scroll technology
Same published duty, three different installation boundaries

The SY presentation describes scroll technology and lists head, receiver-mounted and cabinet arrangements. At the references below, the published point is 11 kW · 8 bar · 1.2 m³/min. Confirm the flow reference conditions and test basis.
Choose the equipment boundary before comparing floor space, lifting weight, cooling and pressure control. A pump/head arrangement leaves more integration work than a receiver or cabinet package.
SY / XT-11 package details →X-11
- Weight
- 91 kg
- Published outline
- 1080 × 270 × 365 mm
Agree mounting, receiver and controls in the installation boundary.
XT-11
- Weight
- 175 kg
- Published outline
- 1550 × 500 × 1000 mm
Check tank drainage, handling and recovery against the demand cycle.
XC-11
- Weight
- 215 kg
- Published outline
- 1200 × 800 × 1000 mm
Reserve ventilation and service access around the enclosure.
For noise-sensitive locations, ask for the selected configuration's measurement conditions. Assess the actual installation, rather than treating a “silent” description as a guaranteed room noise level.
KY cabinet route · Product-page designation KY750*2-65L
Start with the connected instruments and concurrent demand

Published KY family entries
- Working-pressure entry
- 8 bar
- Motor-power range
- 1.5–3 kW
- Receiver choices
- 50 / 65 L
- Weight range
- 120–143 kg
These graphic entries cover several configurations. Confirm the offered cabinet's motor, delivered flow, receiver, weight and outline together on its own data sheet.
Research cabinet selection details →Send a short instrument schedule
| Requirement | Selection purpose |
|---|---|
| Pressure & air consumption | Match delivered air at the actual operating pressure. |
| Concurrent operation & cycle | Check recovery, storage and sustained demand separately. |
| Required air quality | Define drying, filtration and acceptance at the point of use. |
| Location & electrical supply | Agree ventilation, noise conditions, service access and connection. |
Research or medical terminology does not independently qualify the complete air supply for every instrument or clinical application. Use the actual application's acceptance requirements and model-specific evidence.
SY302 · Electric-vehicle onboard compressor
A vehicle assembly needs an OEM interface brief

SUNSOURCE identifies SY302 for a vehicle braking-system application and separately lists CT302 for engineering vehicles. Keep the model and application distinct.
- Electrical: supply-voltage range, current demand and motor/controller interface.
- Pneumatic: pressure cycle, delivered flow and reference conditions, receiver and treatment.
- Mechanical: mounting, vibration, exposure, cooling, intake filtration and service access.
- Validation: vehicle-designer requirements, controls, acceptance conditions and responsibility for the complete system.
Do not transfer ratings from the industrial scroll table or a KY cabinet to an onboard pump. Obtain the selected model's performance and interface drawings for the actual vehicle architecture.
From catalog choice to comparable quotation
Name the configuration, then attach the duty
Air-package order
Pressure/flow basis, demand profile, supply and utilities, treatment boundary, selected arrangement, controls and service space.
Instrument-air order
Instrument schedule, concurrent demand, pressure stability, air quality, cabinet version, receiver and acceptance point.
Vehicle OEM order
Electrical/pneumatic interfaces, environment, drawings, sample configuration and validation responsibilities.
For every route, obtain the exact offered model, general arrangement, performance test basis, model-specific documents, inspection location and routine parts. Itemize options and commissioning separately.
Send a SUNSOURCE configuration and duty →SUNSOURCE buying questions
Are X-11, XT-11 and XC-11 the same package?
The table lists the same 11 kW,8 bar,1.2 m³/min point, but head, receiver and cabinet arrangements have different weights and outlines. Confirm the selected configuration and included controls.
Does the KY graphic give one exact cabinet specification?
It presents family ranges and choices. Request the selected motor, receiver, flow, weight and dimensions on the exact offered cabinet's data sheet.
What must I specify for the water-lubricated screw line?
Air pressure and delivery, demand cycle, electrical supply, cooling and water requirements, treatment and maintenance boundary, tied to the current model/version.
Can SY302 be installed from the product photo alone?
Vehicle integration requires electrical, pneumatic and mechanical interface documents and validation agreed with the vehicle designer and supplier.