Oil-free
Water-lubricated oil-free screw compressors · A08075W / A0815w — Sunsource
Water-lubricated oil-free screw compressors · A08075W / A0815w · Sunsource
Datasheet
Product overview
Power: Model-specific selection sheet required · Pressure: Specify pressure at the air user · Flow: Request matched delivered-air data
SUNSOURCE identifies A08075W and A0815w in its water-lubricated oil-free screw-compressor catalog. The official A08075W photograph shows an enclosed package with an operator panel and the manufacturer's original branding. The model references identify this equipment route; the exact offered version should be selected from a current performance sheet and arrangement drawing.
Begin with required pressure and delivered air at the users, allowing for distribution and treatment losses. Give normal, minimum and peak demand, operating hours, ambient conditions and available electrical supply. Obtain the selected model's flow reference conditions, performance test basis and complete-package input power. A model designation should not be decoded into an unsupported power, pressure or capacity value.
Water lubrication introduces a utility and maintenance boundary that needs to be agreed explicitly. Ask the factory to specify water quality, source, replenishment, drainage, cooling arrangement and service procedure for the offered machine. Identify responsibility for each utility connection and for operation after a supply interruption. The equipment's own general arrangement should define its footprint, lifting requirements, connections and service clearances.
Define air quality at the point of use, including moisture, particles and oil where relevant, and put filters, dryer, receiver and drains on the supply list. Oil-free compression alone does not establish process-air certification or dryness for the entire installation. Keep the exact model, electrical configuration, control arrangement and treatment boundary on the quotation and acceptance procedure. Before an OEM or production order, request model-specific documents, the agreed test point, inspection location and routine spare-parts list; compare alternative offers only on the same duty and included scope.
| Catalog reference | SUNSOURCE-OILFREE-SCREW |
|---|---|
| Machine | Oil-free |
| Power | Model-specific selection sheet required |
| Working pressure | Specify pressure at the air user |
| Published flow | Request matched delivered-air data |
| Air quality | — |
| Duty | Food / pharma |
| Supply | Not specified |
| Plant | Sunsource |
| Official model references | A08075W; A0815w |
| Technology | Water-lubricated oil-free screw air compression |
| Configuration | Enclosed compressor package |
| Required performance | Delivered air at selected pressure and reference conditions |
| Utilities | Agree electrical supply, cooling and water specification |
| Air quality | Define drying, filtration and quality at point of use |
| Acceptance | Exact model/version, performance sheet, general arrangement and supply boundary |
| Photograph | Official A08075W product-page image |
Plant
Sunsource
Wenling
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
- SUNSOURCE-SILENT · 11 kW · XT-11 table reference
- SUNSOURCE-LAB · KY family motor range 1.5–3 kW
- SUNSOURCE-EV · Agree vehicle supply and motor-control interface
Specification pages
Specifying a Oil-free duty
| Duty | Write on the RFQ |
|---|---|
| Oil-free screw compressor manufacturers in China | Oil-free screw is a different factory from oil-injected screw. Dry airends and water-lubricated airends are also different quotes. Name the architecture. |
| Compressor for a food factory | Food air is a validation file. Class, test point and treatment matter as much as kW. A general 8 bar screw without papers is not a food quote. |
| Compressor for a pharmaceutical plant | Pharma procurement is a document pack: IQ/OQ support, material certs, residual oil. The machine is the easy part if the RFQ lists the papers. |
Same type
Related Oil-free products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
FEIHE-FHOGDWYFeihe water-lubricated oil-free screw — WY / PM / WYH selections
|
Oil-free | Selected PM8F / PM22F: 7.5 / 22 kW | PM examples 0.8 MPa; WYH separately | PM22F 1.1–3.7 m³/min at 0.8 MPa | — | Feihe | RFQ |
CMN-CMPVCMN CM/PV water-lubricated PM VSD screw — cooling variants
|
Oil-free | Selected CM22PV:22 kW; table examples7.5–315 kW | CM22PV rows:0.8 / 1.0 / 1.25 MPa | CM22PV:1.40–3.50 m³/min at0.8 MPa | — | CMN | RFQ |
HENGDA-LP-SEMIHengda ZW, VW and double-machine low-pressure semi-oil-free series
|
Oil-free | — | — | — | — | Hengda | RFQ |
HITACHI-DSP-NEXT2Hitachi DSP NEXT II — 90A and 110W catalogue examples
|
Oil-free | 90A: 90 kW; 110W: 110 kW motor | 0.75 / 0.86 / 1.0 MPaG | 90A: 16.4 / 13.9 / 13.4 m³/min | — | Hitachi IEC | RFQ |
HANDE-OILFREEHD-DSPM dry screw and Hande oil-free equipment
|
Oil-free | 90 kW · HD-DSPM90 example | 0.8 MPa (8 bar) · HD-DSPM90 | 14.9 m³/min · HD-DSPM90 | — | Hande | RFQ |
AE-OILFREE-SCREWAOF / AOFM dry oil-free screw compressors
|
Oil-free | 55 kW · AOF55 / AOFM55 examples | — | Delivery at agreed pressure / reference basis | — | Zhongshan AE Machinery | RFQ |
SUNSOURCE-OILFREE-SCREW: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ