Process gas
Hangyang nitrogen reciprocating compressor duty selections — Hangzhou Hangyang Compressor
Hangyang nitrogen reciprocating compressor duty selections · Hangzhou Hangyang Compressor
Datasheet
Product overview
Power: 400 / 185 kW, distinct nitrogen duties · Pressure: 0.108 → 3 or 0.105 → 9.5 MPa; inlet absolute · Flow: 2160 / 660 m³/h, source reference to confirm
Hangyang's nitrogen table gives model-specific flow, inlet/outlet states, speed, motor and cooling-water requirements. ZW-36/30 is listed at 2,160 m³/h, 0.108 MPa(A) inlet and 34°C, with 3 MPa outlet and 40°C. It runs at 593 rpm with a Y5001-10 motor rated 400 kW / 6,000 V and a total water figure of 45 t/h. The source labels this flow m³/h without N, and gives outlet pressure as MPa without an absolute/gauge indication. Request these reference conditions in the technical offer.
Its arrangement table gives vertical construction, three rows and three stages, with installation dimensions of 7,500 × 5,000 × 3,600 mm and 20,000 kg mass. ZW-11/95 is a separate higher-pressure duty: 660 m³/h, 0.105 MPa(A) inlet at 35°C, 9.5 MPa outlet at 40°C, 590 rpm and a Y355L2-10P motor rated 185 kW / 380 V. Its water figure is 12.5 t/h. That machine is vertical, three rows and four stages, at 3,800 × 3,200 × 3,000 mm and 9,776 kg.
Neither duty can be selected from discharge pressure alone. Define nitrogen purity and impurities, source pressure over operation, inlet temperature, volume reference and the receiving-system requirement. Review cooling supply and return conditions, power and starting method, piping/support interfaces, sealing and vent scope, and current arrangement drawings with maintenance space. Ask for the actual project's pulsation/vibration analysis and performance/acceptance records. The nitrogen-family photograph illustrates the manufacturer catalog; it does not prove the depicted assembly is either named model.
| Catalog reference | HANGYANG-N2 |
|---|---|
| Machine | Process gas |
| Power | 400 / 185 kW, distinct nitrogen duties |
| Working pressure | 0.108 → 3 or 0.105 → 9.5 MPa; inlet absolute |
| Published flow | 2160 / 660 m³/h, source reference to confirm |
| Air quality | — |
| Duty | Energy / gas |
| Supply | Not specified |
| Plant | Hangzhou Hangyang Compressor |
| Medium / mechanism | Nitrogen; engineered reciprocating compressor selections |
| Flow notation | Source m³/h, no N on these selected rows; confirm reference conditions |
| Pressure notation | Source inlet MPa(A); source outlet MPa, basis to confirm |
| ZW-36/30 flow / inlet / outlet | 2160 m³/h; 0.108 MPa(A), 34°C; 3 MPa, 40°C |
| ZW-36/30 speed / motor | 593 rpm; Y5001-10; 400 kW / 6000 V |
| ZW-36/30 total water / arrangement | 45 t/h; vertical; 3 rows; 3 stages |
| ZW-36/30 installation dimensions / mass | 7500 × 5000 × 3600 mm; 20000 kg |
| ZW-11/95 flow / inlet / outlet | 660 m³/h; 0.105 MPa(A), 35°C; 9.5 MPa, 40°C |
| ZW-11/95 speed / motor | 590 rpm; Y355L2-10P; 185 kW / 380 V |
| ZW-11/95 total water / arrangement | 12.5 t/h; vertical; 3 rows; 4 stages |
| ZW-11/95 installation dimensions / mass | 3800 × 3200 × 3000 mm; 9776 kg |
| Installation review | Current foundation, lifting, access and package-boundary drawings |
| Photo | Original nitrogen-family photograph; exact selected-model identity not established |
Plant
Hangzhou Hangyang Compressor
Hangzhou
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
Specification pages
Specifying a Process gas duty
| Duty | Write on the RFQ |
|---|---|
| Process gas compressor manufacturers in China | Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused. |
Same type
Related Process gas products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries
|
Process gas | — | — | — | — | Jinxing | RFQ |
ENRIC-CNGEnric modular CNG compression and filling-station modules
|
Process gas | Selected driver and station duty | Selected suction / delivery envelope | 300–6,700 Nm³/h · compressor family range | — | Enric | RFQ |
JEREH-GASJereh natural-gas boosting compressor packages
|
Process gas | Historic project example: 1,253 kW driver | Project-specific suction and delivery pressure | Gas throughput: define normal-volume basis | — | Jereh | RFQ |
LIBANG-N2Boxed oil-free nitrogen reciprocating compressors
|
Process gas | 4.0–5.5 kW, selected 20 Nm³/h models | Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet | 20 Nm³/h, selected models; confirm basis | — | Libang | RFQ |
HANGYANG-O2Hangyang oxygen reciprocating compressor duty selections
|
Process gas | 850 / 110 kW, distinct oxygen duties | 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute | 10000 / 550 N in source flow column; confirm basis | — | Hangyang | RFQ |
JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections
|
Process gas | Selected D rows: 132 / 355 / 280 kW | Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa | 5 / 10 / 22 m³/min, separate selected duties | — | Jiangxi Gas Compressor — JY Ganzhou | RFQ |
Product information
Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
HANGYANG-N2: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ