Process gas

Hangyang oxygen reciprocating compressor duty selections — Hangzhou Hangyang Compressor

Hangyang oxygen reciprocating compressor duty selections · Hangzhou Hangyang Compressor

Hangyang oxygen reciprocating compressor duty selections — official catalog illustration
Hangyang oxygen reciprocating compressor duty selections — manufacturer catalog illustration

Datasheet

Product overview

Power: 850 / 110 kW, distinct oxygen duties · Pressure: 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute · Flow: 10000 / 550 N in source flow column; confirm basis

Hangyang's oxygen tables describe separate engineered reciprocating compressor duties. The large 2Z16-166.67/10.8-50 entry gives 10,000 with an N notation in the m³/h flow column, 1.156 MPa(A) inlet at 30°C and 4.998 MPa outlet at 40°C. Its speed is 428 rpm, motor 850 kW at 6,000 V and total cooling-water figure 85 t/h. Confirm the normal-volume reference conditions and outlet pressure basis; the source marks inlet absolute but does not assign the outlet column an absolute or gauge basis.

The corresponding arrangement table describes a vertical two-row, two-stage unit weighing 33,250 kg. Its 6,900 × 7,000 mm entry is explicitly a two-level layout, not a three-dimensional overall shipping size. The smaller 2LY9.2/30-Ⅱ entry gives 550 with N notation, 0.103 MPa(A) inlet at 30°C and 3.04 MPa outlet at 40°C, at 485 rpm with 110 kW / 380 V and 10 t/h total cooling water. This vertical three-row, three-stage configuration lists 4,500 × 4,500 × 2,800 mm and 8,500 kg.

These are different models with different inlet states, not two sizes on an interchangeable pressure curve. Identify oxygen purity and impurities, the source-pressure range, required output and destination use. Request gas-contact material and cleanliness specifications, sealing/leakage and vent arrangements, cooling conditions, protection/interlock scope and the offered model's performance-test basis. The original workshop image represents the oxygen family and does not identify either selected model. A standards drafting role or group affiliation does not establish the order's oxygen-service acceptance.

Catalog referenceHANGYANG-O2
MachineProcess gas
Power850 / 110 kW, distinct oxygen duties
Working pressure1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute
Published flow10000 / 550 N in source flow column; confirm basis
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantHangzhou Hangyang Compressor
Medium / mechanismOxygen; reciprocating compressor duty selections
Pressure notationSource inlet MPa(A); source outlet MPa, basis to confirm
2Z16-166.67/10.8-50 flow10000 N in source m³/h column; confirm normal reference conditions
2Z16-166.67/10.8-50 inlet / outlet1.156 MPa(A), 30°C / 4.998 MPa, 40°C
2Z16-166.67/10.8-50 speed / motor / water428 rpm; 850 kW / 6000 V; 85 t/h
2Z16-166.67/10.8-50 arrangement / massVertical; 2 rows; 2 stages; 33250 kg
2Z16-166.67/10.8-50 installation entryTwo-level layout 6900 × 7000 mm, not overall L × W × H
2LY9.2/30-Ⅱ flow550 N in source m³/h column; confirm normal reference conditions
2LY9.2/30-Ⅱ inlet / outlet0.103 MPa(A), 30°C / 3.04 MPa, 40°C
2LY9.2/30-Ⅱ speed / motor / water485 rpm; 110 kW / 380 V; 10 t/h
2LY9.2/30-Ⅱ arrangement / size / massVertical; 3 rows; 3 stages; 4500 × 4500 × 2800 mm; 8500 kg
Cooling-water figuresSource total water t/h; confirm supply state and system scope
PhotoOriginal oxygen-family workshop image; exact selected-model identity not established

Plant

Hangzhou Hangyang Compressor

Hangzhou

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a Process gas duty

All spec pages
DutyWrite on the RFQ
Process gas compressor manufacturers in China Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused.

Same type

Related Process gas products

Compare the published product information for each manufacturer.

Full Process gas list
Catalog ref.TypePowerPressureFlowAir qualityPlant
JINXING-STORAGE Jinxing gas-storage and CNG compressor package enquiries JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries Process gas — — — — Jinxing RFQ
ENRIC-CNG Enric modular CNG compression and filling-station modules ENRIC-CNGEnric modular CNG compression and filling-station modules Process gas Selected driver and station duty Selected suction / delivery envelope 300–6,700 Nm³/h · compressor family range — Enric RFQ
JEREH-GAS Jereh natural-gas boosting compressor packages JEREH-GASJereh natural-gas boosting compressor packages Process gas Historic project example: 1,253 kW driver Project-specific suction and delivery pressure Gas throughput: define normal-volume basis — Jereh RFQ
LIBANG-N2 Boxed oil-free nitrogen reciprocating compressors LIBANG-N2Boxed oil-free nitrogen reciprocating compressors Process gas 4.0–5.5 kW, selected 20 Nm³/h models Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet 20 Nm³/h, selected models; confirm basis — Libang RFQ
JXG-D-HYDROGEN JY D-family hydrogen reciprocating compressor selections JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections Process gas Selected D rows: 132 / 355 / 280 kW Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa 5 / 10 / 22 m³/min, separate selected duties — Jiangxi Gas Compressor — JY Ganzhou RFQ
ORIENT-DF Orient DF reciprocating process-compressor platform ORIENT-DFOrient DF reciprocating process-compressor platform Process gas Selected process-duty driver Gas duty and frame selection Composition and volume basis required — Shanghai Orient Compressor Manufacturing RFQ

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

HANGYANG-O2: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ