Process gas
Hangyang oxygen reciprocating compressor duty selections — Hangzhou Hangyang Compressor
Hangyang oxygen reciprocating compressor duty selections · Hangzhou Hangyang Compressor
Datasheet
Product overview
Power: 850 / 110 kW, distinct oxygen duties · Pressure: 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute · Flow: 10000 / 550 N in source flow column; confirm basis
Hangyang's oxygen tables describe separate engineered reciprocating compressor duties. The large 2Z16-166.67/10.8-50 entry gives 10,000 with an N notation in the m³/h flow column, 1.156 MPa(A) inlet at 30°C and 4.998 MPa outlet at 40°C. Its speed is 428 rpm, motor 850 kW at 6,000 V and total cooling-water figure 85 t/h. Confirm the normal-volume reference conditions and outlet pressure basis; the source marks inlet absolute but does not assign the outlet column an absolute or gauge basis.
The corresponding arrangement table describes a vertical two-row, two-stage unit weighing 33,250 kg. Its 6,900 × 7,000 mm entry is explicitly a two-level layout, not a three-dimensional overall shipping size. The smaller 2LY9.2/30-Ⅱ entry gives 550 with N notation, 0.103 MPa(A) inlet at 30°C and 3.04 MPa outlet at 40°C, at 485 rpm with 110 kW / 380 V and 10 t/h total cooling water. This vertical three-row, three-stage configuration lists 4,500 × 4,500 × 2,800 mm and 8,500 kg.
These are different models with different inlet states, not two sizes on an interchangeable pressure curve. Identify oxygen purity and impurities, the source-pressure range, required output and destination use. Request gas-contact material and cleanliness specifications, sealing/leakage and vent arrangements, cooling conditions, protection/interlock scope and the offered model's performance-test basis. The original workshop image represents the oxygen family and does not identify either selected model. A standards drafting role or group affiliation does not establish the order's oxygen-service acceptance.
| Catalog reference | HANGYANG-O2 |
|---|---|
| Machine | Process gas |
| Power | 850 / 110 kW, distinct oxygen duties |
| Working pressure | 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute |
| Published flow | 10000 / 550 N in source flow column; confirm basis |
| Air quality | — |
| Duty | Energy / gas |
| Supply | Not specified |
| Plant | Hangzhou Hangyang Compressor |
| Medium / mechanism | Oxygen; reciprocating compressor duty selections |
| Pressure notation | Source inlet MPa(A); source outlet MPa, basis to confirm |
| 2Z16-166.67/10.8-50 flow | 10000 N in source m³/h column; confirm normal reference conditions |
| 2Z16-166.67/10.8-50 inlet / outlet | 1.156 MPa(A), 30°C / 4.998 MPa, 40°C |
| 2Z16-166.67/10.8-50 speed / motor / water | 428 rpm; 850 kW / 6000 V; 85 t/h |
| 2Z16-166.67/10.8-50 arrangement / mass | Vertical; 2 rows; 2 stages; 33250 kg |
| 2Z16-166.67/10.8-50 installation entry | Two-level layout 6900 × 7000 mm, not overall L × W × H |
| 2LY9.2/30-Ⅱ flow | 550 N in source m³/h column; confirm normal reference conditions |
| 2LY9.2/30-Ⅱ inlet / outlet | 0.103 MPa(A), 30°C / 3.04 MPa, 40°C |
| 2LY9.2/30-Ⅱ speed / motor / water | 485 rpm; 110 kW / 380 V; 10 t/h |
| 2LY9.2/30-Ⅱ arrangement / size / mass | Vertical; 3 rows; 3 stages; 4500 × 4500 × 2800 mm; 8500 kg |
| Cooling-water figures | Source total water t/h; confirm supply state and system scope |
| Photo | Original oxygen-family workshop image; exact selected-model identity not established |
Plant
Hangzhou Hangyang Compressor
Hangzhou
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
Specification pages
Specifying a Process gas duty
| Duty | Write on the RFQ |
|---|---|
| Process gas compressor manufacturers in China | Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused. |
Same type
Related Process gas products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries
|
Process gas | — | — | — | — | Jinxing | RFQ |
ENRIC-CNGEnric modular CNG compression and filling-station modules
|
Process gas | Selected driver and station duty | Selected suction / delivery envelope | 300–6,700 Nm³/h · compressor family range | — | Enric | RFQ |
JEREH-GASJereh natural-gas boosting compressor packages
|
Process gas | Historic project example: 1,253 kW driver | Project-specific suction and delivery pressure | Gas throughput: define normal-volume basis | — | Jereh | RFQ |
LIBANG-N2Boxed oil-free nitrogen reciprocating compressors
|
Process gas | 4.0–5.5 kW, selected 20 Nm³/h models | Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet | 20 Nm³/h, selected models; confirm basis | — | Libang | RFQ |
JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections
|
Process gas | Selected D rows: 132 / 355 / 280 kW | Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa | 5 / 10 / 22 m³/min, separate selected duties | — | Jiangxi Gas Compressor — JY Ganzhou | RFQ |
ORIENT-DFOrient DF reciprocating process-compressor platform
|
Process gas | Selected process-duty driver | Gas duty and frame selection | Composition and volume basis required | — | Shanghai Orient Compressor Manufacturing | RFQ |
Product information
Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
HANGYANG-O2: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ