Shanghai

ELANG: match the air duty, cooling route and mobile configuration

ERC pressure-matched delivery, ERCG dry compression and EL diesel packages, with separate installation and acceptance requirements.

埃朗工业(上海)有限公司 · ELANG group

Stationary air, dry compression or a diesel site package?

Elang Industrial (Shanghai) belongs to the ELANG group, whose company presentation locates its Shanghai operations in Nanxiang, Jiading. The group records expanded mainland compressor production and assembly from 1999 and the opening of its Nantong factory on 27 October 2023.

Original ELANG company photograph identified by the manufacturer as its Nantong factory
Manufacturer's Nantong factory photograph. Confirm the actual manufacturing and inspection location for the ordered equipment.

A catalog hosted by the Hannover Messe organizer connects the same Elang Industrial (Shanghai) identity with Shanghai and Nantong. It is manufacturer-supplied catalog material, rather than an independent factory audit.

ERC: electrically driven stationary screw air, with pressure-matched delivery and a chosen cooling version.

ERCG: dry oil-free compression, with a separate quality and treatment brief.

EL: diesel mobile air, with tool demand, engine and transport conditions.

The wider group catalog also covers variable-frequency, low- and medium-pressure, heat-recovery and after-treatment equipment. The existing product routes below focus on three distinct procurement decisions.

ERC direct-driven stationary screw

Read pressure and delivery as a pair

Original ELANG direct-drive gallery photograph showing an open compressor enclosure
Official direct-drive gallery photograph; it does not identify the pictured package as ERC-30SA/SW.

The motor rating stays the same across each model group's published duty selections. Available air changes with pressure. Compare the required compressor discharge pressure after allowing for losses between the compressor and the user.

The webpage calls the values air delivery. Obtain the test/reference conditions and complete-package input power before comparing another supplier's FAD or specific power.

ERC direct-drive equipment details →
Current ERC table: air delivery in m³/min at each working pressure
Model group / motor7 bar8 bar10 bar12.5 bar
ERC-30SA/SW · 22 kW3.83.63.22.5
ERC-40SA/SW · 30 kW5.35.04.33.6

Selection brief: user pressure, minimum/normal/peak demand and shift pattern; receiver, controls and treatment scope. A 22 kW motor is not a measured 22 kW complete-station consumption figure.

Installation changes with the offered version

Choose SA or SW before sizing the utility connection

Air-cooled route

The ERC-30SA/SW table's applicable air-cooling entry is 110 m³/min cooling air; ERC-40SA/SW lists 145 m³/min.

Request ventilation and duct limits, inlet/ambient conditions, heat rejection and service access for the selected package. Plan where hot exhaust air goes.

Water-cooled route

The alternative cooling-water entries are 14.5 L/min for ERC-30SA/SW and 20 L/min for ERC-40SA/SW.

Obtain inlet temperature, water quality, available pressure, pressure drop and connection requirements. The flow alone does not define an adequate cooling-water system.

ERC-30SA/SW physical entry
1,380 × 850 × 1,150 mm · 640 kg · 1¼-inch air connection.
ERC-40SA/SW physical entry
1,450 × 900 × 1,220 mm · 900 kg · 1¼-inch air connection.

These are preliminary published values. Use the approved selected-machine drawing for foundations, handling, clearance and final utility work; do not add both cooling alternatives to every package.

ERCG dry oil-free route

Separate the compression path from the installed air-quality result

Original ELANG dry-compressor diagram with compressed air, cooling water and oil circuits distinguished
Original manufacturer's system diagram. It explains circuits, rather than depicting a delivered machine.

ELANG describes low- and high-pressure rotor sections, interstage cooling and water separation. The diagram distinguishes compressed air, cooling water and lubricating oil. Gear or bearing lubrication is separate from injecting oil into the compression chamber.

For a quality-sensitive user, specify moisture, particles and total oil at the point of use, treatment, sampling and applicable selected-model evidence. Dry compression alone does not define the whole installed system's air quality.

ERCG selection and installation details →
  • At enquiry: continuous/peak consumption, quality requirement, ambient/inlet conditions and cooling availability.
  • At design approval: electrical version, cooling arrangement, treatment losses, condensate, cooler and maintenance access.
  • At acceptance: selected-machine performance and quality evidence with the agreed operating and sampling conditions.

EL diesel mobile screw

Air duty, engine and chassis belong to one configuration

Original ELANG mobile compressor family photograph showing trailer chassis and open hood
Original mobile-family image; selected model, engine and towing arrangement need their own configuration confirmation.

EL120 · smaller published example

Air delivery / pressure
3.5 m³/min at 7 bar
Engine
Yanmar 3TNV88 · 26.8 kW at 3,000 rpm
Size / handling mass
2,853 × 1,272 × 1,092 mm · 880 kg
Outlet arrangement
Two G¾ outlets

EL250 · separate selection

Air delivery / pressure
7 m³/min at 8 bar
Engine
YC4DK100-T3 · 73 kW at 2,300 rpm
Size / handling mass
3,170 × 1,600 × 1,770 mm · 1,650 kg
Check before transport
Delivered chassis, towbar, brakes and lifting arrangement

For tools, sandblasting or drilling, give the actual user requirement, simultaneous demand, hose length and operating hours. Add altitude, temperature, dust, cold-start needs and movement between sites. An engine power figure does not directly specify tool air capacity.

Agree the engine version, fuel/service needs, destination emissions documentation and transport suitability. A trailer-style picture does not establish road approval.

EL diesel equipment and site brief →

From the build to the buyer's acceptance

Ask for records that identify the ordered package

Original ELANG quality-process illustration showing material, assembly, machine and delivery checks
Manufacturer-published quality-process illustration, not an inspection certificate for a buyer's serial number.
  1. Material and components

    Specify the agreed air end, motor or engine and critical options. Request traceability or scoped documents where the order requires them.

  2. Assembly configuration

    Tie cooling, voltage/frequency or engine/chassis choices to the model and revision on the build and installation documents.

  3. Machine test

    Agree working pressure, air-delivery reference conditions and package input or engine operating conditions. Define what the acceptance record must show.

  4. Delivery inspection

    Match serial identification, packing, handling dimensions, included accessories, manuals and initial service parts to the quotation.

Attach a brief that can produce a comparable offer

ERC: pressure-matched delivery, demand pattern, electrical supply, SA/SW utilities and station scope.

ERCG: corrected model sheet, point-of-use quality, cooling, treatment and sampling/acceptance scope.

EL: tool duty, hoses, engine/chassis, site conditions and transport/engine documentation.

For each route, confirm the actual seller and manufacturer, manufacturing/inspection location, installation and commissioning responsibilities, required scoped conformity documents and routine spares.

Send an ELANG equipment and site brief →

Questions specific to an ELANG selection

Can I use the ERC flow at 7 bar for a 10 bar enquiry?

Use the pressure-matched entry. ERC-30SA/SW lists 3.8 m³/min at7bar and3.2 at10bar. Confirm reference conditions and losses between the package and the user.

Does SW cooling require the listed cooling-air volume too?

The table contains alternative air- and water-cooling entries. Confirm the delivered version and its complete installation requirements rather than adding both listed flows automatically.

Which precise ERCG rating should go on the order?

Request a corrected selected-model sheet because the current webpage's table headings are inconsistent. Family extrema cannot define one machine's simultaneous duty.

Can I combine the older EL catalog with the current engine row?

Keep each document edition and engine/chassis configuration intact. Use the accepted current selection on the order and confirm final transport and operating information.

Shanghai

Other works in this cluster

Shanghai Jiading

OSG

XD direct-drive and EX fixed-speed screw; cooling variants · Plant-air treatment and service scope

Shanghai Baoshan

Feihe

Water-lubricated oil-free screw · FHOGY diesel portable and FHLY centrifugal air packages

Specification pages

Specification pages for Elang Industrial product types

All spec pages
DutyWrite on the RFQ
How to specify an air compressor If the RFQ only says “compressor, China”, a plant cannot price it. Start with architecture, then the duty point, then the papers.
Oil-free screw compressor manufacturers in China Oil-free screw is a different factory from oil-injected screw. Dry airends and water-lubricated airends are also different quotes. Name the architecture.
Compressor for mining Site air at altitude is not a 7 bar catalogue FAD. Diesel vs electric, hose length and ambient change the machine.
75 kW 8 bar rotary screw compressor 75 kW at 8 bar(g) is a common plant-air point. FAD is not a brochure range — it is the flow at that pressure, after the cooler, for the voltage you actually run.

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

Elang Industrial: ERC pressure-matched delivery, ERCG dry compression and EL diesel packages, with separate installation and acceptance requirements.

Open RFQ