Shanghai

Gairs: water-lubricated single-screw compressors

Ordinary-pressure, low-pressure and medium-pressure single-screw routes need different model records and utility arrangements.

Shanghai Gairs Machinery

Location
Songjiang, Shanghai
Core range on this page
Water-lubricated oil-free single-screw compressors
Existing product routes
OGWBY / OGWY · OGWYD · OGWYE
Prepare Gairs RFQ

A single-screw specialist with three pressure routes

Shanghai Gairs Machinery develops and manufactures single-screw air compressors. Its water-lubricated range separates ordinary-pressure, low-pressure and medium-pressure variable-speed equipment. Choose from the process pressure and demand, then confirm the model, cooling and utility arrangement.

Traceable technical background

The national standards information platform names Shanghai Gairs Machinery as a drafting organisation for JB/T 11882-2025, the water-injected single-screw compressor industry standard, implemented on 1 November 2025.

Standard drafting is technical involvement. For procurement, request the offered machine's applicable performance and acceptance documents; it is a separate question from certification of a model or installation.

Start with pressure at the process

Keep the required flow with its working pressure. The three routes below use different catalogue records; a maximum flow from one pressure does not size a machine at another.

  1. 0.7 / 0.85 / 1.0 MPa

    Ordinary-pressure variable speed

    Compare delivery across the pressure rows for the named OGWY model. Include the required speed-control and cooling version.

    Inspect the 22 kW example →
  2. 0.3 / 0.4 MPa

    Low-pressure process air

    Use the dedicated OGWYD records. Compare demand, distribution losses and air-cooled versus water-cooled installation conditions.

    Inspect the 37 kW example →
  3. 3.0 / 4.0 MPa

    Medium-pressure supply

    Use the OGWYE pressure/model pair and installed-power figure. Include pressure ratings of the complete downstream supply.

    Compare the two 6.0 m³/min examples →

Ordinary-pressure route

Same motor, different pressure-matched delivery

OGWBY family / OGWY model table

The product heading uses OGWBY; the original parameter table uses OGWY codes. For OGWY22F/S, the table lists a 22 kW motor, with delivery changing across its three pressure rows.

The F suffix identifies air cooling and S water cooling. The table also distinguishes conventional variable-frequency and permanent-magnet variable-frequency starting designations. Ask for the full current code and drive sheet.

Review the ordinary-pressure family →
OGWY22F/S · 22 kW motor · catalogue delivery ranges
PressureAir delivery
0.7 MPa1.5–3.7 m³/min
0.85 MPa1.4–3.4 m³/min
1.0 MPa1.2–3.0 m³/min

For varying demand, compare the proposed control range, minimum stable delivery and package input at the required pressure. Confirm catalogue flow reference conditions and test basis before comparing another supplier's FAD figure.

Low-pressure route

Low-pressure capacity has its own cooling conditions

OGWY37FD air-cooled example

Motor power
37 kW
At 0.3 MPa
10.0 m³/min catalogue delivery
At 0.4 MPa
8.5 m³/min catalogue delivery
Catalogue supply / drive
380 V, 50 Hz · Coupling · Variable-frequency starting
Review the low-pressure family →

Air cooling or water cooling?

Air-cooled catalogue reference

Air-supply temperature is listed as no more than ambient temperature +15°C. Specify ventilation and actual site ambient conditions.

Water-cooled catalogue reference

The reference is cooling-water inlet temperature +10°C. Include available cooling-water conditions and the manufacturer's required utility scope.

These are relative air-supply temperature references. They are not pressure-dew-point specifications, and do not establish dry air at the process.

Medium-pressure route

Read installed power from the model record

Gairs OGWYE55F-6.0/30 water-lubricated compressor shown by the manufacturer
Manufacturer photograph of the labelled OGWYE55F-6.0/30 example.

Two air-cooled catalogue examples

Equal listed delivery · different pressure and installed power
Model / dutyInstalled power
OGWYE55F-6.0/30
6.0 m³/min at 3.0 MPa
59 kW
OGWYE75F-6.0/40
6.0 m³/min at 4.0 MPa
75 kW

The “55” in the first model name is not its listed installed-power value. Keep the complete code, pressure, delivery and power basis in the quotation.

Review medium-pressure model information →

Define the complete pressure-rated supply

Include receiver, treatment, connections and downstream components in the order boundary. Request their applicable pressure ratings and inspection documents, plus the selected machine's performance and operating instructions.

Separate the water circuit from air-quality acceptance

Water lubrication is part of the compressor selection. The required quality at the process is a separate system-level requirement. Put both into the enquiry.

01

Lubricating water

Ask for water-quality limits, treatment and make-up requirements, circulation, drainage and service intervals. Name which equipment and consumables are included.

02

Cooling utilities

Confirm F or S construction. For air cooling, specify ventilation and ambient conditions; for water cooling, specify inlet conditions and the required cooling arrangement.

03

Delivered air

State particle, oil and moisture limits at the point of use. Agree the dryer/filter/receiver scope and the sampling location, operating conditions and acceptance records.

Prepare an enquiry that can be compared

  1. Process demand

    Pressure at the use point, simultaneous/peak delivery, operating schedule and distribution constraints. Name the ordinary-, low- or medium-pressure route.

  2. Utilities and quality

    Electricity, ambient and cooling-water availability; make-up-water conditions; required air-quality limits and treatment/acceptance scope.

  3. Proposed configuration

    Full model/control/cooling code, pressure-matched flow, measurement basis, package input, control limits, included water equipment and installation/service documents.

Questions before selecting a Gairs compressor

Can OGWY22F/S deliver 3.7 m³/min at 1.0 MPa?

The reviewed table pairs 3.7 m³/min maximum with 0.7 MPa. At 1.0 MPa it lists 1.2–3.0 m³/min. Keep the pressure and delivery from the same row and confirm the offered configuration's performance basis.

Does the 30 L water figure size my cooling supply?

No. It is listed as lubricating-water volume for OGWY22F/S. Request cooling-water, treatment, make-up and circulation requirements separately for the selected machine.

Is OGWYE55F-6.0/30 a 55 kW package?

The original table lists 59 kW installed power. Request actual package input at your duty; neither a model-name number nor installed power alone establishes measured operating consumption.

Does standard drafting replace a model acceptance report?

No. Gairs' participation in JB/T 11882-2025 is company technical background. Agree applicable model performance, air-quality testing and order documents separately.

Shanghai

Other works in this cluster

Shanghai Jiading

OSG

XD direct-drive and EX fixed-speed screw; cooling variants · Plant-air treatment and service scope

Shanghai Baoshan

Feihe

Water-lubricated oil-free screw · FHOGY diesel portable and FHLY centrifugal air packages

Specification pages

Specification pages for Gairs product types

All spec pages
DutyWrite on the RFQ
Compressor for a pharmaceutical plant Pharma procurement is a document pack: IQ/OQ support, material certs, residual oil. The machine is the easy part if the RFQ lists the papers.
Class 0 oil-free compressor Class 0 means a stated test method at a stated point in the air system. An oil-free airend without a paper is not Class 0 on this desk.
Oil-free screw compressor manufacturers in China Oil-free screw is a different factory from oil-injected screw. Dry airends and water-lubricated airends are also different quotes. Name the architecture.
Compressor for a food factory Food air is a validation file. Class, test point and treatment matter as much as kW. A general 8 bar screw without papers is not a food quote.

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

Gairs: Ordinary-pressure, low-pressure and medium-pressure single-screw routes need different model records and utility arrangements.

Open RFQ