Shanghai

Hanbell air-ends & refrigeration compressors

Choose AA screw, RC2 refrigeration or oil-free scroll by the system duty, then prepare a model-specific enquiry.

Hanbell at a glance

Company
Shanghai Hanbell Precise Machinery Co., Ltd.
Location
Fengjing, Jinshan, Shanghai
Listed identity
Stock code 002158
Families on this page
AA air-ends · RC2 refrigeration · Oil-free scroll
Enquire with Hanbell

Choose the component before the supplier quotation

Hanbell develops compressor and vacuum equipment. Its Shanghai manufacturing operation is associated with Fengjing in Jinshan; the brand history also includes Taiwan operations. Use the exact legal seller and model on the quotation.

The three families below serve different systems. An AA air-end is a compression component. RC2 is for refrigeration. A scroll air-end supplies another compressed-air route. Start with the system you are building or replacing.

Hanbell manufacturing site in mainland China
Hanbell mainland manufacturing site
01

Which Hanbell product fits your enquiry?

Three supply routes. Different selection data.

Hanbell AA single-stage screw air-end

Air-compressor package builders

AA single-stage screw air-end

The compression component for a package you are integrating or repairing. Hanbell separates ordinary-pressure AA from medium-pressure AA-H and low-pressure AB-L; identify the exact family.

Send
Pressure + flow, running speed, drive and mounting arrangement.
Confirm
Air-end-only scope; motor, cooling, lubrication and controls required for the package.
AA model data →
Hanbell RC2 semi-hermetic screw refrigeration compressor

Chillers, air-conditioning and heat pumps

RC2 refrigeration compressor

A semi-hermetic screw family with A/B motor options. Hanbell lists R22, R134a, R407C, R404A and R507; select the exact variant against the refrigeration duty.

Send
Refrigerant, evaporating/condensing conditions, cooling duty, frequency and voltage.
Confirm
Operating envelope, motor variant, part-load and protection/control requirements.
RC2 selection information →
Hanbell oil-free scroll air-end

Oil-free air package integration

Oil-free scroll air-end

The compression chamber is separated from the lubricated transmission, with an integral centrifugal cooling fan. The installation's air treatment and delivered air quality still need selection.

Send
Pressure + delivered-air requirement, demand cycle, ambient and cooling conditions.
Confirm
Selected air-end, operating point and required air-quality evidence for the complete installation.
Scroll operating data →
02

Keep each rating with its operating point

Use matched conditions when comparing a proposed selection.

5.5 kW scroll: pressure changes the flow

Manufacturer-listed 5.5 kW scroll air-end data
PressureAir flowListed power
8 bar600 L/min5.78 kW
10 bar440 L/min6.5 kW

Need 600 L/min at 10 bar? Neither row establishes that duty. Request a selection meeting pressure and flow together.

The rows use different speeds: 3,000 rpm and 2,500 rpm. These are air-end figures, not an independently verified complete-package FAD rating.

03

Agree the order scope before comparing prices

Replacing an air-end

Send the old model, mounting and connection layout, speed and drive information. Similar appearance or motor size alone does not establish compatibility.

Building a new package

Agree the supplied component and accessories. Identify who provides the motor, cooling, oil circuit, controls and downstream air treatment.

Replacing a chiller compressor

Send the original nameplate and system conditions. Confirm RC2 model/motor compatibility and control requirements before agreeing the replacement.

A cold-room or blast-freezing duty needs its own operating-envelope selection. Hanbell identifies separate cold-storage compressor families; the RC2 name alone is insufficient.

04

Prepare a useful Hanbell enquiry

Choose one supply route and send its selection inputs.

For AA or scroll

  • New package or replacement; exact model if known.
  • Pressure and flow at the same operating point.
  • Speed, drive, cooling and mounting requirements.
  • Air-end-only scope or requested package accessories.

For RC2

  • Refrigerant and evaporating/condensing conditions.
  • Required cooling duty and part-load operation.
  • Model/motor variant, voltage and frequency.
  • Existing nameplate and system details for replacement.

Request with the quotation

A selected model sheet, stated rating conditions, drawing and connection information, included accessories and exclusions. Agree inspection records, installation documents, commissioning responsibility and destination spare-parts support before ordering. These are items to agree with the seller, not promised factory services.

Ready to send the operating conditions?

Hanbell will already be selected in the enquiry form.

Prepare Hanbell RFQ

Questions before selecting a model

Does an AA air-end quotation include a complete compressor?

Do not assume so. AA is the compression component. Agree the motor, drive, cooling, lubrication, controls and accessories in the supplied scope.

Can I use the 600 L/min scroll figure at 10 bar?

The official 5.5 kW table lists 600 L/min at 8 bar and 440 L/min at 10 bar. A different model or configuration needs its own documented selection.

Is every RC2 suitable for a cold-storage installation?

Select against the refrigerant, temperatures, motor and operating envelope. The issuer describes RC2 for air-conditioning, ice storage and heat-pump applications and identifies separate cold-storage families.

Does an oil-free scroll air-end certify my process air quality?

Construction alone does not establish the complete installation's air-quality class or suitability for a particular process. Specify the required outlet quality and request matching evidence for the selected package and treatment.

Shanghai

Other works in this cluster

Shanghai Jiading

OSG

XD direct-drive and EX fixed-speed screw; cooling variants · Plant-air treatment and service scope

Shanghai Baoshan

Feihe

Water-lubricated oil-free screw · FHOGY diesel portable and FHLY centrifugal air packages

Specification pages

Specification pages for Hanbell product types

All spec pages
DutyWrite on the RFQ
Compressor for laser cutting Choose the air system from the laser maker's gas specification. The compressor motor rating and laser power do not, by themselves, determine the required pressure, flow or air quality. Identify whether the supply is for cutting assist gas, machine services or both before requesting a package.
Refrigeration screw compressor manufacturers in China A refrigeration screw compressor is selected for a refrigerant and operating conditions. Start with required cooling capacity, evaporating and condensing temperatures, electrical supply and the system arrangement. An air-compressor pressure rating or a motor nameplate alone cannot define this duty.
Compressor for a textile factory Jet looms and spinning do not share a pressure. Write the machine OEM’s bar(g) and the hall FAD, then 50 Hz voltage for most Asian mills.
Compressor for CNC machines Machine tools need dry, stable 7–8 bar air. Size from the cell, not from a round kW number a vendor likes to sell.

Product information

Information reviewed 2026-09-28. Specifications apply only to the models and conditions stated.

Hanbell: Choose AA screw, RC2 refrigeration or oil-free scroll by the system duty, then prepare a model-specific enquiry.

Open RFQ