Scroll
Oil-free scroll air-ends — 3.7 and 5.5 kW families — Hanbell Precise Machinery
Oil-free scroll air-ends — 3.7 and 5.5 kW families · Hanbell Precise Machinery
Datasheet
Product overview
Oil-free scroll air-ends — 3.7 and 5.5 kW families from Hanbell Precise Machinery
Hanbell's oil-free scroll catalog lists 3.7 kW and 5.5 kW air-ends. The orbiting scroll, fixed scroll and housing form the compression mechanism, while the compression chamber is separated from the lubricated transmission. The published design uses an integral centrifugal fan for cooling.
For the 5.5 kW air-end, the model table gives two separate working points. At 8 bar it lists 3,000 rpm and 600 L/min air flow; at 10 bar it lists 2,500 rpm and 440 L/min. The corresponding listed power readings are 5.78 kW and 6.5 kW. The nominal family designation therefore should not be treated as the actual input power at every pressure.
The same table records ambient temperatures of 21 °C and 27.1 °C and discharge temperatures of 172 °C and 205 °C respectively. These are associated table conditions, not universal operating limits. The pressure and flow data here apply to the 5.5 kW example; they should not be transferred to the separately listed 3.7 kW family.
For a complete package, specify the selected air-end, required pressure and air flow, duty cycle, cooling arrangement and downstream air treatment. Oil-free construction alone does not establish a certified air-quality class, dew point or suitability for a particular medical or food-production process.
| Catalog reference | HANBELL-SCROLL |
|---|---|
| Machine | Scroll |
| Power | — |
| Working pressure | — |
| Published flow | — |
| Air quality | — |
| Duty | Food / pharma |
| Supply | Not specified |
| Plant | Hanbell Precise Machinery |
| Catalog families | 3.7 kW and 5.5 kW oil-free scroll air-ends |
| 5.5 kW family / 8 bar | 3000 rpm; air flow 600 L/min; listed power 5.78 kW; current 10.66 A |
| 5.5 kW family / 10 bar | 2500 rpm; air flow 440 L/min; listed power 6.5 kW; current 11.5 A |
| 8 bar table conditions | Ambient 21 °C; discharge temperature 172 °C |
| 10 bar table conditions | Ambient 27.1 °C; discharge temperature 205 °C |
| Cooling | Integral centrifugal fan |
| Construction | Compression chamber separated from lubricated transmission |
| Scope | Pressure/flow examples apply to the 5.5 kW air-end; not the 3.7 kW family |
| Air treatment | Select for the complete installation; no certified air-quality class inferred |
Plant
Hanbell Precise Machinery
Shanghai
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
Same type
Related Scroll products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
SONYO-SCROLLSonyo B-series commercial scroll compressors
|
Scroll | 3.5–7 HP manufacturer family class | Refrigerant pressure: confirm model envelope | — | — | Bingshan Sonyo Compressor | RFQ |
GUANGWO-ATMO-SCROLLGuangwo GW-10D lubricated scroll — paired standard-pressure duties
|
Scroll | Motor rating: obtain clarified nameplate | Paired duties:0.8 /1.0 MPa | 1.05 at0.8 /0.95 at1.0 MPa, m³/min | — | Guangwo | RFQ |
AI-OILFREE-SCROLLANEST IWATA SLPJ single-head and multiple-head oil-free scroll packages
|
Scroll | — | — | — | — | ANEST IWATA | RFQ |
GANEY-OXOXW oil-free scroll compressors
|
Scroll | Selected OXW datasheet required | Selected model / duty to be agreed | Selected-pressure delivery required | — | Ganey | RFQ |
DHH-DCODehaha DCO modular oil-free scroll — 8 bar duty and module counts
|
Scroll | Selected table 3–44 kW; model numbers differ | 8 bar — published table | 0.35–5.20 m³/min at 8 bar — separate models | — | Dehaha | RFQ |
GUANGWO-MP-SCROLLGuangwo GW-15DHY16 lubricated scroll receiver / dryer package
|
Scroll | Motor and dryer ratings: clarified schedule required | 1.6 MPa published duty | 1.0 m³/min at1.6 MPa | — | Guangwo | RFQ |
Product information
Information reviewed 2026-09-28. Specifications apply only to the models and conditions stated.
HANBELL-SCROLL: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ