Wuxi

Wuxi Xiya: match factory air and specialist gas to the duty

Compare FWT oil-free, N-series two-stage and PE/PD portable selections with the right pressure, cooling and supply boundary.

Wuxi Xiya Compressor Co., Ltd. · 无锡锡压压缩机有限公司

A present-day manufacturer with Wuxi Compressor Works heritage

Xiya is part of Wuxi Weike Group, with its published company location in Hongshan, Xinwu District, Wuxi. Its history distinguishes the predecessor factory from the current legal business.

1955

Predecessor works

The company's history traces the earlier Wuxi Compressor Works to 1955. This describes its manufacturing heritage.

July 2016

Present Xiya business

The power-compressor and associated parts operations were reorganised into Wuxi Xiya Compressor Co., Ltd. Use this legal seller identity for an order.

The portfolio spans industrial air and specialist gas compression. A process-gas or helium duty needs its own gas/inlet and acceptance specification; it cannot be selected by transferring a standard air-compressor rating.

Two stationary-air routes · Different compression and cooling choices

Choose the air path, then the pressure-matched configuration

Original Xiya oil-free screw compressor family product illustration
Original oil-free family illustration. Specify the series and table row for the offered machine.

FWT: two-stage oil-free air

The F page separates low-pressure single-stage FWS, two-stage FWT and variable-speed arrangements. These examples are selected from the FWT two-stage table.

FWT examples at 0.8 MPa gauge / 8 barg
Series / rowFlow & motorCooling water
FWT20
Row 1
12 m³/min
90 kW
9 m³/h
FWT35
Row 6
26.5 m³/min
160 kW
16 m³/h

Both rows list 380 V / 50 Hz. The series name spans multiple rows; keep the capacity/motor configuration identified and confirm the delivery reference.

FWT20 row 1
2860 × 1520 × 1870 mm · 3000 kg main unit
FWT35 row 6
3210 × 1870 × 2100 mm · 5300 kg main unit

Use the offered unit's installation/service drawing. A water-flow entry still needs agreed temperature, quality and pressure; air quality still needs drying, particle and point-of-use acceptance requirements.

F-series pressure, cooling and air-quality scope →
Original Xiya two-stage oil-injected screw compressor family illustration
Original two-stage family illustration. FMS and WMS cooling arrangements follow the selected model.

N series: two-stage PM variable-speed plant air

The table explicitly identifies permanent-magnet variable-speed arrangements. Match the pressure and cooling suffix before comparing delivery.

Named N-series motor and pressure pairings
Model / powerAt 8 bargAt 10 barg
N110FMS
110 kW
21.8 m³/min19.9 m³/min
N110WMS
110 kW
21.8 m³/min19.9 m³/min
N132FMS
132 kW
26.5 m³/min23.8 m³/min

FMS is air-cooled; WMS is water-cooled. N110WMS lists 11 m³/h cooling water. Both 110 kW examples list 3200 × 1750 × 1950 mm and 3600 kg; agree the offered package drawing and service clearance.

The source describes delayed stop after unloading, overload and abnormal stage-pressure/high-temperature protection. Agree settings, interfaces and sequencing, then request total package input through the actual shift profile.

N-series model pairings and control/cooling selection →

Portable screw · Electrical supply or diesel drive?

PE and PD have different site and transport questions

Original Xiya PE portable compressor family illustration
Original PE illustration. Obtain a named electric model's motor, pressure and delivery data.

PE: electric-motor-driven

The product category lists 45–200 kW across the electric family. Confirm the selected model's pressure/flow pairing, voltage/frequency, starting arrangement and site cable/supply conditions.

Choose this route around usable electrical supply and mobility requirements. Agree hose/tool pressure losses, outlets, lifting and transport configuration.

Original Xiya PD diesel portable compressor family illustration
Original PD illustration. Engine, chassis and destination requirements follow the selected offer.

PD: diesel-driven

PD7200 / 7201A: 8 m³/min at 0.7 MPa; 93 kW, 4BTA3.9-C125 water-cooled engine. Table dimensions: 3080 × 1550 × 1850 mm; net weight 2000 kg.

PD7400 / 7401A: 21 m³/min at 0.7 MPa; 160 kW, 6CTA8.3-C215 engine. Table dimensions: 4000 × 1900 × 2260 mm; net weight 4260 kg.

Confirm capacity reference, actual engine/emissions documents, fuel/cooling and site altitude/ambient conditions. A portable illustration does not establish road approval.

Portable drive, duty and transport selection →

Specialist process duty · Helium is not plant air

Bring the inlet and gas conditions into the specification

An April 2024 report hosted by the Chinese Academy of Sciences' Technical Institute of Physics and Chemistry identifies Xiya in helium screw-compressor development and describes its work on inlet-pressure regulation.

The manufacturer's helium table uses mass flow in g/s and absolute inlet/discharge pressure. Its air tables use m³/min and gauge pressure. These duties need different reference conditions and gas properties.

A process enquiry needs more than a flow number

  • Gas composition, impurities, inlet pressure and temperature.
  • Mass flow/reference conditions and required discharge duty.
  • Allowable leakage/contamination, cooling and interfaces.
  • Project-specific materials, controls, tests and acceptance boundary.

Identify whether the request is a standard air package or an engineered gas project. Agree the offered machine's actual configuration and acceptance requirements.

Original Xiya helium compressor product illustration
Manufacturer's helium-family illustration. It does not assign the surrounding project's duties to a standard air machine.

Turn a catalog choice into a complete, comparable quotation

1 · Identify the selection

FWT series/row, N-series cooling suffix, PE/PD model or a separate process-gas duty. State pressure/reference, demand profile, hours and site conditions.

2 · Define the package

Drive/control, treatment, receiver, cooling and electrical supply. Include installation, service access, transport and interfaces.

3 · Agree acceptance

Legal seller, assembly/test site and model/serial records. Define performance/input tests, air-quality evidence where needed, destination documents and commissioning/parts scope.

Prepare a Wuxi Xiya enquiry

Resolve these differences before comparing offers

Was the present Xiya legal company founded in 1955?

The manufacturer's history dates the predecessor Wuxi Compressor Works to 1955 and the formation of the present Xiya business to July 2016. Keep the order's legal entity separate from the predecessor's heritage.

Does FWT20 identify one fixed flow and motor rating?

The table has several configurations under FWT20. The stated row 1 example is 12 m³/min at 0.8 MPa gauge with 90 kW. Identify the table row and chosen pressure/motor arrangement in the offer.

Are N110FMS and N110WMS interchangeable installation choices?

They have the same listed pressure/flow pairing but different cooling routes. WMS lists cooling-water demand; FMS needs its ventilation and heat-discharge arrangement. Confirm supply and service conditions before selecting.

Can I apply PD engine specifications to a PE electric model?

PE and PD are separate drive routes. Use the stated PD examples for their named diesel models and obtain a corresponding PE motor/pressure/flow datasheet for an electric enquiry.

Can helium g/s be compared directly with air m³/min?

Gas properties, inlet and reference conditions are needed for conversion. Xiya's helium table also uses absolute pressure, while the reviewed air tables use gauge pressure. Specify the gas and duty before comparing capacities.

Wuxi

Other works in this cluster

Wuxi

Turbo-Tech

Centrifugal air · Process-gas centrifugal

Wuxi

Jufeng

Oil-injected/oil-free screw · Laser-cutting packages

Wuxi Xinwu

Atlas Copco

Oil-injected screw · Oil-free screw

Wuxi · Huishan

Guangdong Jufeng

Oil-injected screw assembly (Jufeng / Oudefeng brands)

Specification pages

Specification pages for Xiya product types

All spec pages
DutyWrite on the RFQ
How to specify an air compressor If the RFQ only says “compressor, China”, a plant cannot price it. Start with architecture, then the duty point, then the papers.
Compressor for a pharmaceutical plant Pharma procurement is a document pack: IQ/OQ support, material certs, residual oil. The machine is the easy part if the RFQ lists the papers.
Compressor for mining Site air at altitude is not a 7 bar catalogue FAD. Diesel vs electric, hose length and ambient change the machine.
75 kW 8 bar rotary screw compressor 75 kW at 8 bar(g) is a common plant-air point. FAD is not a brochure range — it is the flow at that pressure, after the cooler, for the voltage you actually run.

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

Xiya: Compare FWT oil-free, N-series two-stage and PE/PD portable selections with the right pressure, cooling and supply boundary.

Open RFQ