Process gas

AET process-gas and booster compressors — Zhongshan AE Machinery

AET process-gas and booster compressors · Zhongshan AE Machinery

AET process-gas and booster compressors — official catalog illustration
AET process-gas and booster compressors — manufacturer catalog illustration

Datasheet

Product overview

Power: 55 / 37 kW · two nitrogen duty examples · Pressure: N₂:4→20 bar /8→80 bar · Flow: N₂:600 /200 Nm³/h at distinct inlet duties

AE's process-gas page separates nitrogen, natural-gas and petroleum-gas parameter tables. It also describes development of hydrogen, biogas and carbon-dioxide equipment. Gas compatibility and safety requirements must be selected for the actual composition and operating envelope; a catalog capability is not approval of every gas mixture.

The nitrogen table lists AET-2.2/4-20 at 4 bar inlet, 20 bar discharge, 600 Nm³/h, 55 kW and two stages. AET-0.4/8-80 is a different point: 8 bar inlet, 80 bar discharge, 200 Nm³/h, 37 kW and three stages. Keep inlet pressure with the capacity; these examples cannot be compared as outputs at a common suction condition.

The natural-gas table separately gives AET-3.2/1-250 at 1→250 bar, 350 Nm³/h, 90 kW and four stages. The petroleum-gas table gives AET-2.5/2-8 at 2→8 bar, 400 Nm³/h, 22 kW and one stage. Confirm gauge/absolute pressure and normal-volume reference temperature/pressure. Do not equate Nm³/h with an air-compressor m³/min figure on another basis.

Submit composition, contaminants and moisture, suction pressure/temperature range, discharge duty and continuous/peak demand. Obtain the selected process datasheet, arrangement, utility list, materials/seal specification, protection/interlocks and destination compliance documents. Agree acceptance methods, manuals, spare parts and commissioning support. The original range illustration does not establish a particular package's model, rating or hazardous-area approval.

Catalog referenceAE-PROCESS-GAS
MachineProcess gas
Power55 / 37 kW · two nitrogen duty examples
Working pressureN₂:4→20 bar /8→80 bar
Published flowN₂:600 /200 Nm³/h at distinct inlet duties
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantZhongshan AE Machinery
Nitrogen example 1AET-2.2/4-20
Example 1 pressure4 bar inlet → 20 bar discharge
Example 1 flow / drive600 Nm³/h; 55 kW; 2 stages
Nitrogen example 2AET-0.4/8-80
Example 2 pressure8 bar inlet → 80 bar discharge
Example 2 flow / drive200 Nm³/h; 37 kW; 3 stages
Natural-gas modelAET-3.2/1-250
Natural-gas duty1 → 250 bar; 350 Nm³/h; 90 kW; 4 stages
Petroleum-gas modelAET-2.5/2-8
Petroleum-gas duty2 → 8 bar; 400 Nm³/h; 22 kW; 1 stage
Pressure basisConfirm gauge versus absolute
Normal-volume basisConfirm reference temperature and pressure
Gas briefComposition, contaminants and moisture
Suction envelopeInlet temperature and pressure range
Engineering scopeMaterials, seals, cooling and protection
Acceptance scopeInterlocks, destination requirements and tests
Original range imageObtain the selected model arrangement

Plant

Zhongshan AE Machinery

Zhongshan

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a Process gas duty

All spec pages
DutyWrite on the RFQ
Process gas compressor manufacturers in China Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused.

Same type

Related Process gas products

Compare the published product information for each manufacturer.

Full Process gas list
Catalog ref.TypePowerPressureFlowAir qualityPlant
JINXING-STORAGE Jinxing gas-storage and CNG compressor package enquiries JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries Process gas — — — — Jinxing RFQ
ENRIC-CNG Enric modular CNG compression and filling-station modules ENRIC-CNGEnric modular CNG compression and filling-station modules Process gas Selected driver and station duty Selected suction / delivery envelope 300–6,700 Nm³/h · compressor family range — Enric RFQ
JEREH-GAS Jereh natural-gas boosting compressor packages JEREH-GASJereh natural-gas boosting compressor packages Process gas Historic project example: 1,253 kW driver Project-specific suction and delivery pressure Gas throughput: define normal-volume basis — Jereh RFQ
LIBANG-N2 Boxed oil-free nitrogen reciprocating compressors LIBANG-N2Boxed oil-free nitrogen reciprocating compressors Process gas 4.0–5.5 kW, selected 20 Nm³/h models Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet 20 Nm³/h, selected models; confirm basis — Libang RFQ
HANGYANG-O2 Hangyang oxygen reciprocating compressor duty selections HANGYANG-O2Hangyang oxygen reciprocating compressor duty selections Process gas 850 / 110 kW, distinct oxygen duties 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute 10000 / 550 N in source flow column; confirm basis — Hangyang RFQ
JXG-D-HYDROGEN JY D-family hydrogen reciprocating compressor selections JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections Process gas Selected D rows: 132 / 355 / 280 kW Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa 5 / 10 / 22 m³/min, separate selected duties — Jiangxi Gas Compressor — JY Ganzhou RFQ

AE-PROCESS-GAS: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ