Process gas

Aipu BOG-to-pipeline recovery — LNG boil-off gas duties — Bengbu Aipu Compressor

Aipu BOG-to-pipeline recovery — LNG boil-off gas duties · Bengbu Aipu Compressor

Aipu BOG-to-pipeline recovery — LNG boil-off gas duties — official catalog illustration
Original manufacturer-labelled ZW-2.7/(1-4)-6 BOG package; its model differs from the selected numerical rows.

Datasheet

Product overview

Power: Selected ZW rows:30 /37 kW · Pressure: Selected ZW:0.5 MPa discharge;inlet varies · Flow: Selected ZW rows:650 /800 /850 Nm³/h

Aipu presents this page specifically as BOG recovery into a gas pipeline. Applications include LNG storage boil-off and residual gas after tanker unloading, with L-CNG, reserve, peak-shaving and gasification stations and liquefaction plants named. Other Aipu routes for recovery into LNG tanks or making CNG are distinct package purposes and should not be assumed to share this configuration.

ZW-4.0/(1-4)-5 lists 800 Nm³/h, 0.1–0.4 MPa inlet, 0.5 MPa discharge and 37 kW. ZW-3.3/(1.5-4)-5 gives 650 Nm³/h, 0.15–0.4 MPa inlet, 0.5 MPa discharge and 30 kW. ZW-4.4/(1.5-4)-5 gives 850 Nm³/h with the same printed inlet/discharge pressures and 37 kW. All three rows list 2000 × 1600 × 2200 mm. Published inlet ranges do not establish constant flow at every suction condition.

A different low-inlet row, DW-5.7/(0.1-0.15)-18, lists 330 Nm³/h at 0.01–0.015 MPa inlet, 1.8 MPa discharge, 75 kW and 3500 × 3000 × 3000 mm. This illustrates a distinct pressure task, not a universal high-pressure version of the small ZW skid. Neither row establishes a liquid-LNG pumping duty or every cryogenic inlet condition.

The source uses normal-volume Nm³/h without complete reference temperature/pressure and does not explicitly settle gauge/absolute pressure. Provide gas composition, inlet temperature/pressure envelope, transient boil-off/ unloading profile, normal/base/peak flow and receiving-pipeline pressure. Define liquid separation, conditioning, condensate/vent routing, materials/seals, controls, shutdowns, hazardous-area and acceptance boundaries with the offered process proposal.

Request P&ID, utility demand, offered-model performance points, site interface/dimensions and service clearances, interlock and control protocol schedules, test plan and manuals. Agree operator training, spare parts, commissioning and destination service. Aipu's published dispatch/commissioning warranty start points and domestic response wording need contract-specific scope. The original photograph is labelled ZW-2.7/(1-4)-6 BOG recovery, an illustrative manufacturer package distinct from the selected ZW-4.0/-3.3/-4.4 table examples.

Catalog referenceAIPU-BOG
MachineProcess gas
PowerSelected ZW rows:30 /37 kW
Working pressureSelected ZW:0.5 MPa discharge;inlet varies
Published flowSelected ZW rows:650 /800 /850 Nm³/h
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantBengbu Aipu Compressor
ApplicationLNG boil-off and tanker residual gas recovery into pipeline
Capacity basisNm³/h;normal reference to agree
ZW-4.0/(1-4)-5800 Nm³/h;0.1–0.4 MPa inlet;0.5 MPa discharge;37 kW
ZW-3.3/(1.5-4)-5650 Nm³/h;0.15–0.4 MPa inlet;0.5 MPa discharge;30 kW
ZW-4.4/(1.5-4)-5850 Nm³/h;0.15–0.4 MPa inlet;0.5 MPa discharge;37 kW
Three ZW envelopes2000 × 1600 × 2200 mm
DW-5.7/(0.1-0.15)-18330 Nm³/h;0.01–0.015 MPa inlet;1.8 MPa discharge;75 kW;3500 × 3000 × 3000 mm
BoundaryActual temperature,liquid separation,pipeline pressure and control scope
ImageOriginal ZW-2.7/(1-4)-6 BOG example;not all listed models

Plant

Bengbu Aipu Compressor

Bengbu

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a Process gas duty

All spec pages
DutyWrite on the RFQ
Process gas compressor manufacturers in China Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused.

Same type

Related Process gas products

Compare the published product information for each manufacturer.

Full Process gas list
Catalog ref.TypePowerPressureFlowAir qualityPlant
JINXING-STORAGE Jinxing gas-storage and CNG compressor package enquiries JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries Process gas — — — — Jinxing RFQ
ENRIC-CNG Enric modular CNG compression and filling-station modules ENRIC-CNGEnric modular CNG compression and filling-station modules Process gas Selected driver and station duty Selected suction / delivery envelope 300–6,700 Nm³/h · compressor family range — Enric RFQ
JEREH-GAS Jereh natural-gas boosting compressor packages JEREH-GASJereh natural-gas boosting compressor packages Process gas Historic project example: 1,253 kW driver Project-specific suction and delivery pressure Gas throughput: define normal-volume basis — Jereh RFQ
LIBANG-N2 Boxed oil-free nitrogen reciprocating compressors LIBANG-N2Boxed oil-free nitrogen reciprocating compressors Process gas 4.0–5.5 kW, selected 20 Nm³/h models Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet 20 Nm³/h, selected models; confirm basis — Libang RFQ
HANGYANG-O2 Hangyang oxygen reciprocating compressor duty selections HANGYANG-O2Hangyang oxygen reciprocating compressor duty selections Process gas 850 / 110 kW, distinct oxygen duties 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute 10000 / 550 N in source flow column; confirm basis — Hangyang RFQ
JXG-D-HYDROGEN JY D-family hydrogen reciprocating compressor selections JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections Process gas Selected D rows: 132 / 355 / 280 kW Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa 5 / 10 / 22 m³/min, separate selected duties — Jiangxi Gas Compressor — JY Ganzhou RFQ

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

AIPU-BOG: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ