Process gas
FKW hydrogen filling and refuelling compressor configurations — FENDY Jinkaiwei (Changshu)
FKW hydrogen filling and refuelling compressor configurations · FENDY Jinkaiwei (Changshu)
Datasheet
Product overview
Power: 30–200 or 30–185 kW motor bands · Pressure: 45 / 90 MPaG configurations · Flow: 200–2000 / 100–1000 Nm³/h envelopes
The official hydrogen filling table separates two high-pressure envelopes: 45 MPaG discharge with 3–20 MPaG inlet, 200–2,000 Nm³/h and a 30–200 kW motor band; and 90 MPaG discharge with 10–30 MPaG inlet, 100–1,000 Nm³/h and 30–185 kW. Both list one or two stages. These are configuration ranges, not a single guaranteed operating point or constant capacity at every inlet pressure.
Give the source-storage pressure curve and replenishment schedule, hydrogen analysis, buffer/cascade arrangement, daily volume and peak filling events. Request capacity and absorbed/package input across the actual suction range. Preserve the normal-volume reference: production-feed figures in Nm³/min are a separate table, not per-hour filling capacities.
Specify the boundary between compressor skid, source treatment, storage, dispensing, cooling, ventilation and controls. Agree safe vent/recovery handling, detection/interlocks, utility conditions, actual package dimensions and service access. The 70 MPa rating of a receiving vehicle/station application does not by itself define compressor discharge or dispensing protocol.
Obtain the offered model and complete performance sheet, factory/site test plan, measurement tolerances, commissioning and warranty scope. The official blue package photograph illustrates the hydrogen category; it is not proven to be the government-reported test unit. A dated project's shaft-power result must not be substituted for this catalogue's motor band or whole-station electricity use.
| Catalog reference | FKW-HRS |
|---|---|
| Machine | Process gas |
| Power | 30–200 or 30–185 kW motor bands |
| Working pressure | 45 / 90 MPaG configurations |
| Published flow | 200–2000 / 100–1000 Nm³/h envelopes |
| Air quality | — |
| Duty | Energy / gas |
| Supply | Not specified |
| Plant | FENDY Jinkaiwei (Changshu) |
| 45 MPaG discharge envelope | Inlet3–20 MPaG;flow200–2000 Nm³/h;motor30–200 kW;1–2 stages |
| 90 MPaG discharge envelope | Inlet10–30 MPaG;flow100–1000 Nm³/h;motor30–185 kW;1–2 stages |
| Range meaning | Separate configuration envelopes;not simultaneous endpoints |
| Flow basis | Filling table Nm³/h;production-feed table Nm³/min is separate |
| Duty inputs | Source-pressure decay,hydrogen quality,daily and peak demand,cascade |
| Boundary | Skid versus treatment,storage,dispensing,cooling and controls |
| Acceptance | Matched operating-case tests and actual selected model |
Plant
FENDY Jinkaiwei (Changshu)
Suzhou
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
- FKW-PISTON · 75–5600 kW frame motor ceilings
- FKW-DIAPHRAGM · Selected-model input and motor required
Specification pages
Specifying a Process gas duty
| Duty | Write on the RFQ |
|---|---|
| Process gas compressor manufacturers in China | Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused. |
Same type
Related Process gas products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries
|
Process gas | — | — | — | — | Jinxing | RFQ |
ENRIC-CNGEnric modular CNG compression and filling-station modules
|
Process gas | Selected driver and station duty | Selected suction / delivery envelope | 300–6,700 Nm³/h · compressor family range | — | Enric | RFQ |
JEREH-GASJereh natural-gas boosting compressor packages
|
Process gas | Historic project example: 1,253 kW driver | Project-specific suction and delivery pressure | Gas throughput: define normal-volume basis | — | Jereh | RFQ |
LIBANG-N2Boxed oil-free nitrogen reciprocating compressors
|
Process gas | 4.0–5.5 kW, selected 20 Nm³/h models | Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet | 20 Nm³/h, selected models; confirm basis | — | Libang | RFQ |
HANGYANG-O2Hangyang oxygen reciprocating compressor duty selections
|
Process gas | 850 / 110 kW, distinct oxygen duties | 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute | 10000 / 550 N in source flow column; confirm basis | — | Hangyang | RFQ |
JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections
|
Process gas | Selected D rows: 132 / 355 / 280 kW | Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa | 5 / 10 / 22 m³/min, separate selected duties | — | Jiangxi Gas Compressor — JY Ganzhou | RFQ |
Product information
Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
FKW-HRS: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ