Process gas
Hydrogen diaphragm compression · engineered skid selection — Xinran
Hydrogen diaphragm compression · engineered skid selection · Xinran
Datasheet
Product overview
Power: 25 kN frame reference · 22 kW maximum motor · Pressure: Family ceiling ≤100 MPa(G) · select actual duty · Flow: Hydrogen flow depends on inlet and staged selection
Xinran offers diaphragm compression for hydrogen and other gas-process enquiries. The manufacturer describes a diaphragm arrangement in which the compressed gas does not contact the lubricating system. The family table lists one to three stages and a discharge-pressure ceiling of 100 MPa(G). Frame-force, stroke and maximum motor-power entries differ across the range: the 25 kN column gives a 105 mm stroke and 22 kW maximum motor power.
These are family and frame-selection data. They do not establish a hydrogen capacity at 100 MPa, an absorbed package-power figure or the rating of every skid. Specify hydrogen composition and purity, inlet pressure and temperature, outlet pressure, normal and peak flow with reference conditions and the operating cycle. Label gauge and absolute pressures clearly and describe the downstream storage or process arrangement.
Work with the project engineer and factory to define stage design, gas-contact materials, interstage cooling, separation and drainage where applicable. Agree leak monitoring, relief and shutdown boundaries, purging, hazardous-area requirements and the response to utility or control failures. The manufacturer's general gas list is not evidence that one unchanged configuration is suitable for every gas or project. Keep the offered diaphragm, seals, valves and materials tied to the actual hydrogen duty.
Request the selected frame and motor, process and instrumentation documents, general arrangement, utilities, controls and commissioning responsibilities. Define performance and leakage acceptance criteria for the exact configuration, together with maintenance procedures and routine spares. The original photograph illustrates the diaphragm product family; the delivered skid layout must come from the approved drawing. Compare offers on the same inlet state, outlet requirement, flow basis and supply boundary, rather than on a family pressure ceiling alone.
| Catalog reference | XINRAN-H2 |
|---|---|
| Machine | Process gas |
| Power | 25 kN frame reference · 22 kW maximum motor |
| Working pressure | Family ceiling ≤100 MPa(G) · select actual duty |
| Published flow | Hydrogen flow depends on inlet and staged selection |
| Air quality | — |
| Duty | Energy / gas |
| Supply | Not specified |
| Plant | Xinran |
| Technology | Diaphragm gas compression |
| Family compression stages | 1–3 |
| Family discharge-pressure ceiling | ≤100 MPa(G); not every configuration's duty rating |
| Frame reference | 25 kN |
| Reference stroke | 105 mm |
| Reference maximum motor power | 22 kW; not absorbed package power |
| Required duty | Hydrogen composition/purity, inlet temperature and pressure, outlet pressure, flow reference conditions and operating cycle |
| Supply boundary | Engineered skid, cooling, controls, monitoring and project-specific safety provisions |
| Photograph | Official diaphragm product-family illustration |
Plant
Xinran
Shanghai
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
- XINRAN-TWOSTAGE · 15 kW · XR-15SY reference
- XINRAN-OILFREE-LP · 55 kW · S55A/XR reference
- XINRAN-MAGLEV · Engineered duty · obtain package input power
Specification pages
Specifying a Process gas duty
| Duty | Write on the RFQ |
|---|---|
| Process gas compressor manufacturers in China | Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused. |
Same type
Related Process gas products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries
|
Process gas | — | — | — | — | Jinxing | RFQ |
ENRIC-CNGEnric modular CNG compression and filling-station modules
|
Process gas | Selected driver and station duty | Selected suction / delivery envelope | 300–6,700 Nm³/h · compressor family range | — | Enric | RFQ |
JEREH-GASJereh natural-gas boosting compressor packages
|
Process gas | Historic project example: 1,253 kW driver | Project-specific suction and delivery pressure | Gas throughput: define normal-volume basis | — | Jereh | RFQ |
LIBANG-N2Boxed oil-free nitrogen reciprocating compressors
|
Process gas | 4.0–5.5 kW, selected 20 Nm³/h models | Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet | 20 Nm³/h, selected models; confirm basis | — | Libang | RFQ |
HANGYANG-O2Hangyang oxygen reciprocating compressor duty selections
|
Process gas | 850 / 110 kW, distinct oxygen duties | 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute | 10000 / 550 N in source flow column; confirm basis | — | Hangyang | RFQ |
JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections
|
Process gas | Selected D rows: 132 / 355 / 280 kW | Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa | 5 / 10 / 22 m³/min, separate selected duties | — | Jiangxi Gas Compressor — JY Ganzhou | RFQ |
Product information
Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
XINRAN-H2: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ