Shanghai Success Engine Compressor Co., Ltd. · 上海申行健压缩机有限公司
From an individual compressor to a defined air-system supply
Success Engine designs, manufactures and supports compressor systems. Its published location is Songjiang, Shanghai, and its range includes oil-injected screw, dry oil-free screw, medium-pressure and two-stage equipment, centrifugal selections and customised packages.
The manufacturer describes processing and testing equipment and a workshop area of over 20,000 m². For procurement, connect the selected machine to an agreed assembly/test location, inspection schedule and order documents.
Start with required pressure and air quality
Three purchasing routes need different comparison sheets
Choose a named pressure/flow pairing, then the cooling and station accessories.
02 · Dry oil-free compressionZA low or standard pressureSeparate the 1.5 bar duty from the 7–10 bar selections before comparing capacity.
03 · Engineered large flowCentrifugal packageCompare an identified configuration and performance map against the site's demand profile.
SE: the pressure suffix changes the quoted delivery

The motor drives the airend through a flexible direct coupling. The catalog keeps pressure-specific models separate. Match the full model code to the factory pressure requirement.
| Model / motor | Pressure | Air flow |
|---|---|---|
| SE22A-8/D 22 kW | 8 bar | 3.6 m³/min |
| SE30A-8/D 30 kW | 8 bar | 5.0 m³/min |
| SE75A-8/D 75 kW | 8 bar | 13.0 m³/min |
| SE75A-10/D 75 kW | 10 bar | 10.9 m³/min |
At 75 kW, the 10 bar selection has a different flow from the 8 bar selection. Include downstream treatment and distribution pressure losses when defining the machine duty; ask for the delivery reference and matched package input.
SE model, controls and installation details →Allow space for the selected enclosure
SE22A-8/D: 1300 × 860 × 1340 mm, 630 kg, Rp 1 1/4 outlet. SE30A-8/D: 1450 × 860 × 1340 mm, 690 kg.
The 75 kW table group lists 2000 × 1200 × 1585 mm and 1580 kg. These outline dimensions still need service clearance and lifting/transport details.
Agree cooling and controls
The range describes air or water cooling, removable doors, PLC protective alarms and a 485 / MODBUS interface.
For air cooling, define heat removal and intake conditions. For water cooling, define flow, temperature, pressure and quality. Confirm registers, remote commands and multi-machine sequencing on the offered controller.
ZA · Two pressure duties, separate model groups
A larger flow at 1.5 bar is not a replacement at 7 bar

The ZA dry compression description keeps injected oil and other compression liquids out of the compression chamber. Select between the low-pressure and standard-pressure tables using the process pressure.
| Model / motor | Pressure | Air flow |
|---|---|---|
| ZA55A(W)-7 55 kW | 7 bar | 8.9 m³/min |
| ZA55A(W)-8 55 kW | 8 bar | 7.8 m³/min |
| ZA55A(W)-10 55 kW | 10 bar | 7.4 m³/min |
| ZA75(W)-1.5 75 kW | 1.5 bar | 20 m³/min |
The ZA55 group lists DN50 outlet, 1500 kg and 2300 × 1300 × 1780 mm. The ZA75 low-pressure group lists DN65, 2100 kg and 2900 × 2300 × 1880 mm. Confirm the actual cooling suffix and installation drawing.
ZA operating and delivered-air requirements →Centrifugal · Build the selection around the operating map
Specify compressor duty before sizing the station

The technical summary's family envelope
- Input power
- 150–6000 kW
- Discharge pressure
- 1–25 bar
- Inlet volume
- 40–800 m³/min
These bounds span different selections. Request a named configuration and matched pressure/flow performance map; do not combine the maximum entries into one duty point.
The manufacturer's wider portfolio includes low-pressure blowers and vacuum equipment. Their pressure and flow tables describe separate duties.
Bring the station's real operating conditions
- Inlet pressure, temperature, humidity and site altitude.
- Discharge pressure and minimum/normal/peak flow by shift.
- Stable operating range, controls and any blow-off at low demand.
- Total package input, motor supply and starting arrangement.
- Cooling duty, cooler access and treatment/storage boundary.
Inlet-volume flow needs a reference state before comparison with free-air delivery or normal volume. Agree this in the technical offer.
Centrifugal package selection and exclusions →Ask for a quotation that separates machine and station scope
Define the compressor
State the SE pressure suffix, ZA pressure/cooling configuration or centrifugal selection duty. Include hours, demand profile, electrical supply, ambient conditions and required air quality.
List the auxiliary equipment
Itemise dryer, filtration, receiver, drains, pipework, controls and cooling supply. Identify the pressure and quality at the delivery point, plus installation and maintenance access.
Make acceptance traceable to the order
Confirm legal seller, assembly/test location, model/serial records, package drawing and pressure/flow/input test conditions. Agree destination documents, commissioning, spare parts and responsibilities.
Questions that change a Success Engine selection
Which company name belongs on the technical offer?
Use Shanghai Success Engine Compressor Co., Ltd., with Chinese identity 上海申行健压缩机有限公司. Keep the brand, legal seller, model and assembly/test location connected in the order documentation.
Why are the two 75 kW SE capacities different?
SE75A-8/D lists 13.0 m³/min at 8 bar; SE75A-10/D lists 10.9 m³/min at 10 bar. Choose the pressure-matched model and ask for the delivery reference and package input at that duty.
Can ZA75(W)-1.5 supply the same process as ZA55A(W)-7?
The examples deliver at 1.5 bar and 7 bar respectively. Their flows are not interchangeable when the process needs the higher pressure. Include treatment and distribution losses when choosing the required compressor pressure.
Does a dry oil-free compressor automatically supply dry or sterile air?
Oil, moisture, particles and hygienic requirements are separate. Specify treatment, pressure dew point and point-of-use acceptance; obtain any model-specific certificate required by the process.
What does the 2022 sampled energy-label result establish?
The regulator's January 2023 notice concerns the named SE37A-81D sample and inspected metrology requirements. Obtain current offered-model data for an order; the historical sample is not a whole-range certification.