Centrifugal

JTL industrial centrifugal fans — F double-suction example — Jintongling Technology Group

JTL industrial centrifugal fans — F double-suction example · Jintongling Technology Group

JTL industrial centrifugal fans — F double-suction example — official catalog illustration
JTL industrial centrifugal fans — F double-suction example — manufacturer catalog illustration

Datasheet

Product overview

Power: 110–8,000 kW or larger · F family · Pressure: Up to 30,000 Pa · F family endpoint · Flow: Up to 1,500,000 m³/h · F family endpoint

JTL's industrial fan catalog separates fan duty from JE/JED compressor duty. The F double-suction example describes rotors above 1,600 mm in double-supported construction, a special foundation arrangement and factory preassembly. Its original image shows the catalog equipment, not a guaranteed configuration for every process.

The published family endpoints include impeller size up to 4,000 mm, flow up to 1,500,000 m³/h and pressure up to 30,000 Pa, with gas temperature −20 to 500°C. The motor range is 110–8,000 kW or larger. Those values do not describe one simultaneous operating point. Request the selected fan curve and pressure definition at the agreed gas temperature, density and interfaces.

Provide contaminants, corrosion/erosion conditions, required flow, pressure and duct/system resistance. Agree actual coupling/driver, foundation loads, alignment, cooling, seals, dampers, expansion joints, filtering/silencing and bearing monitoring. A fan pressure entry must not be compared as if it were the compressor's outlet barG.

Tie material and rotor/balance records to the supplied equipment, then define shop/site acceptance, handling, installation, access and commissioning. For repair or replacement, include the existing nameplate and operating/failure history and agree the inspection and shutdown scope.

Catalog referenceJTL-CENTRI-FAN
MachineCentrifugal
Power110–8,000 kW or larger · F family
Working pressureUp to 30,000 Pa · F family endpoint
Published flowUp to 1,500,000 m³/h · F family endpoint
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantJintongling Technology Group
Selected catalog exampleF double-suction centrifugal fan
ConstructionDouble-supported rotor; special design and factory preassembly
Impeller family limitUp to 4,000 mm
Flow / pressure family endpointsUp to 1,500,000 m³/h / up to 30,000 Pa
Motor family range110–8,000 kW or larger
Published gas temperature range−20 to 500°C
DriveDirect coupling
Materials describedCarbon steel or stainless steel
Seals describedLabyrinth, carbon ring or nitrogen sealing
SelectionEndpoints are not one simultaneous operating point
Order inputsGas state, pressure definition, duct interfaces and foundation

Plant

Jintongling Technology Group

Nantong

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a Centrifugal duty

All spec pages
DutyWrite on the RFQ
Compressor for wastewater treatment Most aeration trains want low-pressure blowers. If this RFQ is actually 7–8 bar plant air for valves and instruments, say so — it is a different machine from a maglev blower.
Centrifugal compressor manufacturers in China Centrifugal machines are duty-built. A 250 kW “centrifugal compressor China” RFQ without gas, suction and discharge pressure cannot be quoted.

Same type

Related Centrifugal products

Compare the published product information for each manufacturer.

Full Centrifugal list
Catalog ref.TypePowerPressureFlowAir qualityPlant
JTL-INDUSTRIAL-AIR JTL JE centrifugal air compressors and JED single-stage range JTL-INDUSTRIAL-AIRJTL JE centrifugal air compressors and JED single-stage range Centrifugal JE6000: 355–800 kW · configuration range JE: 2.2–10.5 barG · select operating point JE6000: 80–130 m³/min · reference basis to agree — Jintongling RFQ
HANWHA-CENTRI Hanwha SM / SM100 Pro centrifugal air compressor selections HANWHA-CENTRIHanwha SM / SM100 Pro centrifugal air compressor selections Centrifugal SM2100 150–335; SM3100 Pro 250–600 kW SM2100 5.0–11.4 bar(A); Pro duty to select SM2100 1400–3550; Pro 3300–5690 m³/h — Hanwha Power Shanghai — compressor sales and service RFQ
TLINGTE-TI Turbo-Tech Ti centrifugal air and nitrogen compressors TLINGTE-TITurbo-Tech Ti centrifugal air and nitrogen compressors Centrifugal Driver selected to duty 0.06–1.60 MPa(G), family envelope 1200–24000 Nm³/h, family envelope — Turbo-Tech RFQ
HYTP-ISOTHERMAL-AIR Hangyang single-shaft isothermal main-air compressors HYTP-ISOTHERMAL-AIRHangyang single-shaft isothermal main-air compressors Centrifugal Motor or steam turbine;duty-specific Selected main-air delivery duty ASU scale below40,000 Nm³/h;not air flow — Hangyang Turbine RFQ
IHI-SULLAIR-TX IHI-Sullair TX centrifugal air — 4–9 barg series selection IHI-SULLAIR-TXIHI-Sullair TX centrifugal air — 4–9 barg series selection Centrifugal TX series:150–425 kW TX series:4–9 barg Offered model flow/reference required — IHI-Sullair RFQ
SHAANGU-E Shaangu E horizontal-split process centrifugal compressors SHAANGU-EShaangu E horizontal-split process centrifugal compressors Centrifugal Selected train driver/input to agree Actual gas operating envelope required Project-specific flow/map and reference — Shaangu RFQ

JTL-CENTRI-FAN: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ