Centrifugal
KFAS DA single-shaft centrifugal compressor engineering references — Kaifeng Air Separation Group (KFAS)
KFAS DA single-shaft centrifugal compressor engineering references · Kaifeng Air Separation Group (KFAS)
Datasheet
Product overview
Power: 1040 kW shaft power, code 6060 · Pressure: 0.097 to 0.70 MPa absolute · Flow: 210 m³/min, code 6060
DA is KFAS's single-shaft centrifugal route for engineered air supply, including air-separation installations and independent industrial air packages. The original technical table records specific model/project selections. Treat it as an engineering reference and obtain a current selection at the buyer's actual suction state.
DA200-61 code 6060 lists air at 210 m³/min, 0.097 MPa absolute suction, 0.70 MPa absolute discharge, 11,543 rpm and 1,040 kW shaft power. The same model under code 6060L lists 230 m³/min, 0.082 to 0.63 MPa absolute, the same shaft speed and 1,110 kW shaft power. The complete code and duty matter: selecting only the shared model name omits the conditions behind the capacity and power. The published volume heading does not specify normal conditions or FAD, so confirm its reference basis.
The manufacturer's centrifugal overview describes inlet regulation, anti-surge control, shaft monitoring and test capability. Request the offered map with minimum/normal/maximum demand, allowed suction variation, control arrangement and performance-test conditions. Shaft power is not the installed motor rating; agree driver selection, starting method and total package input separately.
Define cooler duty and water conditions, lubrication/auxiliaries, foundations, lifting space and plant-control interfaces. For an air-separation project, relate compressor capacity control to the process air balance and downstream pressure. Obtain a model/serial-number-linked test report, drawings, destination documents, maintenance parts and commissioning scope. The original portfolio photograph illustrates KFAS centrifugal equipment generally; it is not identified as the named DA200-61 reference.
| Catalog reference | KFAS-DA |
|---|---|
| Machine | Centrifugal |
| Power | 1040 kW shaft power, code 6060 |
| Working pressure | 0.097 to 0.70 MPa absolute |
| Published flow | 210 m³/min, code 6060 |
| Air quality | — |
| Duty | Energy / gas |
| Supply | Not specified |
| Plant | Kaifeng Air Separation Group (KFAS) |
| {"Model" | "DA200-61", "Project codes": "6060 / 6060L", "Catalogue gas flow": "210 / 230 m³/min; volume basis to confirm", "Suction pressure": "0.097 / 0.082 MPa absolute", "Discharge pressure": "0.70 / 0.63 MPa absolute", "Shaft power": "1040 / 1110 kW; not motor/package input", "Shaft speed": "11543 rpm"} |
Plant
Kaifeng Air Separation Group (KFAS)
Kaifeng
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
Specification pages
Specifying a Centrifugal duty
| Duty | Write on the RFQ |
|---|---|
| Compressor for wastewater treatment | Most aeration trains want low-pressure blowers. If this RFQ is actually 7–8 bar plant air for valves and instruments, say so — it is a different machine from a maglev blower. |
| Centrifugal compressor manufacturers in China | Centrifugal machines are duty-built. A 250 kW “centrifugal compressor China” RFQ without gas, suction and discharge pressure cannot be quoted. |
Same type
Related Centrifugal products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
JTL-INDUSTRIAL-AIRJTL JE centrifugal air compressors and JED single-stage range
|
Centrifugal | JE6000: 355–800 kW · configuration range | JE: 2.2–10.5 barG · select operating point | JE6000: 80–130 m³/min · reference basis to agree | — | Jintongling | RFQ |
HANWHA-CENTRIHanwha SM / SM100 Pro centrifugal air compressor selections
|
Centrifugal | SM2100 150–335; SM3100 Pro 250–600 kW | SM2100 5.0–11.4 bar(A); Pro duty to select | SM2100 1400–3550; Pro 3300–5690 m³/h | — | Hanwha Power Shanghai — compressor sales and service | RFQ |
TLINGTE-TITurbo-Tech Ti centrifugal air and nitrogen compressors
|
Centrifugal | Driver selected to duty | 0.06–1.60 MPa(G), family envelope | 1200–24000 Nm³/h, family envelope | — | Turbo-Tech | RFQ |
HYTP-ISOTHERMAL-AIRHangyang single-shaft isothermal main-air compressors
|
Centrifugal | Motor or steam turbine;duty-specific | Selected main-air delivery duty | ASU scale below40,000 Nm³/h;not air flow | — | Hangyang Turbine | RFQ |
IHI-SULLAIR-TXIHI-Sullair TX centrifugal air — 4–9 barg series selection
|
Centrifugal | TX series:150–425 kW | TX series:4–9 barg | Offered model flow/reference required | — | IHI-Sullair | RFQ |
SHAANGU-EShaangu E horizontal-split process centrifugal compressors
|
Centrifugal | Selected train driver/input to agree | Actual gas operating envelope required | Project-specific flow/map and reference | — | Shaangu | RFQ |
Product information
Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
KFAS-DA: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ