Process gas
Lianhe CNG station booster — VF and VFD duty comparison — Bengbu Lianhe Compressor
Lianhe CNG station booster — VF and VFD duty comparison · Bengbu Lianhe Compressor
Datasheet
Product overview
Power: Selected VF/VFD table:75 kW · Pressure: Table inlet3–20 → discharge25 MPa;confirm · Flow: Table1500 Nm³/h;header basis differs
Lianhe presents this selection as reciprocating natural-gas equipment for CNG station service, with project-specific packages. Station type and gas source should be specified separately: trailer/storage pressure changes, pipeline input and station sequencing are not one identical duty.
The detailed table gives VF-0.32/(30-200)-250 at 1500 Nm³/h, 3–20 MPa inlet, 25 MPa discharge and 75 kW, with 5538 × 2350 × 2000 mm and 5.5 t. VFD-0.32/(30-200)-250 gives the same printed capacity, pressures and motor, with 5538 × 2350 × 2438 mm and 9.5 t. The source's air-cooled cell spans the table rows. Request actual foundation, enclosure, auxiliaries and service-access drawings rather than assigning the dimension/mass difference solely from a suffix.
The page header also prints 0.32 m³/min and 0.3–20 MPa inlet; the latter differs from the detailed 3–20 MPa row. Agree the inlet limit and flow bases in the signed performance sheet. The header value is not converted to or treated as equivalent to 1500 Nm³/h. Broader station throughput descriptions are not a guaranteed curve for this machine.
Give the complete inlet-pressure profile, composition and temperature, required delivery pressure, average/peak dispensing demand, available electrical supply and storage/sequence concept. Obtain capacity and package-input curves across the pressure envelope, permissible start/stop duty, cooling demand, gas separation/vent routing and hazardous-area scope. Generic claims about control brands, noise, imported components or service hours do not establish the current offered bill of materials or tested operating conditions.
Confirm control/interlock schedules, relief and shutdown interfaces, installation/service clearances, manuals, spares, commissioning, training and acceptance tests. Product-page one-year warranty wording and ongoing support need start points, exclusions and destination terms in the order. The original paired photographs are non-standard manufacturer package examples; they do not establish the configuration of both VF and VFD numerical rows.
| Catalog reference | LIANHE-CNG |
|---|---|
| Machine | Process gas |
| Power | Selected VF/VFD table:75 kW |
| Working pressure | Table inlet3–20 → discharge25 MPa;confirm |
| Published flow | Table1500 Nm³/h;header basis differs |
| Air quality | — |
| Duty | Energy / gas |
| Supply | Not specified |
| Plant | Bengbu Lianhe Compressor |
| Mechanism | Reciprocating natural-gas station compressor |
| VF-0.32/(30-200)-250 table | 1500 Nm³/h;3–20 MPa inlet;25 MPa discharge;75 kW |
| VF installation | 5538 × 2350 × 2000 mm;5.5 t |
| VFD-0.32/(30-200)-250 table | 1500 Nm³/h;3–20 MPa inlet;25 MPa discharge;75 kW |
| VFD installation | 5538 × 2350 × 2438 mm;9.5 t |
| Cooling | Air-cooled table cell spans rows |
| Header distinction | 0.32 m³/min;reference not specified;not converted to Nm³/h |
| Inlet clarification | Header0.3–20 versus table3–20 MPa;confirm signed operating envelope |
| Performance | Capacity/package-input curve across actual changing inlet pressure |
| Scope | Exact station source,storage,controls and protection to agree |
Plant
Bengbu Lianhe Compressor
Bengbu
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
- LIANHE-NG · DWF-5.4:offered motor to confirm
- LIANHE-ASU · VWF nitrogen example:55 kW
Specification pages
Specifying a Process gas duty
| Duty | Write on the RFQ |
|---|---|
| Process gas compressor manufacturers in China | Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused. |
Same type
Related Process gas products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries
|
Process gas | — | — | — | — | Jinxing | RFQ |
ENRIC-CNGEnric modular CNG compression and filling-station modules
|
Process gas | Selected driver and station duty | Selected suction / delivery envelope | 300–6,700 Nm³/h · compressor family range | — | Enric | RFQ |
JEREH-GASJereh natural-gas boosting compressor packages
|
Process gas | Historic project example: 1,253 kW driver | Project-specific suction and delivery pressure | Gas throughput: define normal-volume basis | — | Jereh | RFQ |
LIBANG-N2Boxed oil-free nitrogen reciprocating compressors
|
Process gas | 4.0–5.5 kW, selected 20 Nm³/h models | Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet | 20 Nm³/h, selected models; confirm basis | — | Libang | RFQ |
HANGYANG-O2Hangyang oxygen reciprocating compressor duty selections
|
Process gas | 850 / 110 kW, distinct oxygen duties | 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute | 10000 / 550 N in source flow column; confirm basis | — | Hangyang | RFQ |
JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections
|
Process gas | Selected D rows: 132 / 355 / 280 kW | Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa | 5 / 10 / 22 m³/min, separate selected duties | — | Jiangxi Gas Compressor — JY Ganzhou | RFQ |
LIANHE-CNG: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ