Process gas
Lianhe DWF natural-gas transfer — named duty and package scope — Bengbu Lianhe Compressor
Lianhe DWF natural-gas transfer — named duty and package scope · Bengbu Lianhe Compressor
Datasheet
Product overview
Power: DWF-5.4:offered motor to confirm · Pressure: DWF-5.4:0.17–0.345 →2.1 MPa · Flow: DWF-5.4:5.4 m³/min;reference to agree
Lianhe names DWF-5.4/(1.7-3.45)-21 for natural-gas pressure boosting and transfer. Its header publishes 5.4 m³/min, 0.17–0.345 MPa inlet and 2.1 MPa discharge. The flow reference is not fully stated, and a motor or dimensional value for this named header is not supplied. Do not assign a different family-table row's motor or envelope to DWF-5.4.
The manufacturer's description calls this gas compression non-lubricated and lists compressor, motor, coupling, flywheel, piping, cooling, electrical and auxiliary equipment. Cooling may be water, air or mixed; package forms include fixed, mobile, skid and acoustic enclosure by requirement. Define the actual gas-path lubrication boundary, package drawing and supplied auxiliaries. This wording does not make every bearing or drive mechanism lubricant-free.
A separate table row DW-4.9/(1.5-2.5)-22 lists 700 Nm³/h, 0.15–0.25 MPa inlet, 2.2 MPa discharge, 110 kW and 740 rpm, water cooling, 3800 × 2700 × 1800 mm and approximately 6000 kg. Another separate VWF-1.65/(25-35)-50 row gives 2500 Nm³/h, 2.5–3.5 MPa inlet, 5.0 MPa discharge, 90 kW and air cooling. These are family selection examples, not specifications of the pictured DWF header machine.
The page describes alarms/stops for low oil pressure, low water pressure, high temperature, low inlet pressure and high discharge pressure, with remote display/control by requirement. Obtain offered instruments, setpoints, interfaces and shutdown responsibility in the actual control schedule. Generic multi-industry application sentences do not establish food-contact, instrument-air or other gas suitability.
Provide composition, temperature, complete suction envelope, flow basis, required receiving pressure, liquid/contaminant conditions and duty cycle. Agree materials, sealing, purity/carryover, conditioning, vents and cooling utilities. Obtain offered performance, package input, P&ID, electrical/control and installation/foundation drawings, maintenance clearances, manuals and factory/acceptance tests. Specify commissioning, training, warranty scope and destination support. The complete original machine photograph is the manufacturer's non-standard natural-gas example, not every family configuration.
| Catalog reference | LIANHE-NG |
|---|---|
| Machine | Process gas |
| Power | DWF-5.4:offered motor to confirm |
| Working pressure | DWF-5.4:0.17–0.345 →2.1 MPa |
| Published flow | DWF-5.4:5.4 m³/min;reference to agree |
| Air quality | — |
| Duty | Energy / gas |
| Supply | Not specified |
| Plant | Bengbu Lianhe Compressor |
| Named header | DWF-5.4/(1.7-3.45)-21 |
| Gas | Natural gas |
| Header flow | 5.4 m³/min;reference basis not stated |
| Header pressure | 0.17–0.345 MPa inlet;2.1 MPa discharge |
| Named-header motor/envelope | Obtain actual offered sheet;not inferred from another row |
| Gas-path description | Non-lubricated gas compression;drive/bearing lubrication boundary to agree |
| Cooling | Air,water or mixed by requirement |
| Separate DW-4.9/(1.5-2.5)-22 | 700 Nm³/h;0.15–0.25→2.2 MPa;110 kW;740 rpm;water-cooled |
| Separate DW installation | 3800 × 2700 × 1800 mm;approximately6000 kg |
| Separate VWF-1.65/(25-35)-50 | 2500 Nm³/h;2.5–3.5→5.0 MPa;90 kW;air-cooled |
| Protection | Offered oil/water pressure,temperature and gas-pressure alarm/stop schedule |
Plant
Bengbu Lianhe Compressor
Bengbu
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
Specification pages
Specifying a Process gas duty
| Duty | Write on the RFQ |
|---|---|
| Process gas compressor manufacturers in China | Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused. |
Same type
Related Process gas products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries
|
Process gas | — | — | — | — | Jinxing | RFQ |
ENRIC-CNGEnric modular CNG compression and filling-station modules
|
Process gas | Selected driver and station duty | Selected suction / delivery envelope | 300–6,700 Nm³/h · compressor family range | — | Enric | RFQ |
JEREH-GASJereh natural-gas boosting compressor packages
|
Process gas | Historic project example: 1,253 kW driver | Project-specific suction and delivery pressure | Gas throughput: define normal-volume basis | — | Jereh | RFQ |
LIBANG-N2Boxed oil-free nitrogen reciprocating compressors
|
Process gas | 4.0–5.5 kW, selected 20 Nm³/h models | Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet | 20 Nm³/h, selected models; confirm basis | — | Libang | RFQ |
HANGYANG-O2Hangyang oxygen reciprocating compressor duty selections
|
Process gas | 850 / 110 kW, distinct oxygen duties | 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute | 10000 / 550 N in source flow column; confirm basis | — | Hangyang | RFQ |
JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections
|
Process gas | Selected D rows: 132 / 355 / 280 kW | Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa | 5 / 10 / 22 m³/min, separate selected duties | — | Jiangxi Gas Compressor — JY Ganzhou | RFQ |
Product information
Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.
LIANHE-NG: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ