Process gas

Lianhe DWF natural-gas transfer — named duty and package scope — Bengbu Lianhe Compressor

Lianhe DWF natural-gas transfer — named duty and package scope · Bengbu Lianhe Compressor

Lianhe DWF natural-gas transfer — named duty and package scope — official catalog illustration
Complete original DWF-5.4 natural-gas page photograph; manufacturer describes a non-standard package configured for its actual gas duty.

Datasheet

Product overview

Power: DWF-5.4:offered motor to confirm · Pressure: DWF-5.4:0.17–0.345 →2.1 MPa · Flow: DWF-5.4:5.4 m³/min;reference to agree

Lianhe names DWF-5.4/(1.7-3.45)-21 for natural-gas pressure boosting and transfer. Its header publishes 5.4 m³/min, 0.17–0.345 MPa inlet and 2.1 MPa discharge. The flow reference is not fully stated, and a motor or dimensional value for this named header is not supplied. Do not assign a different family-table row's motor or envelope to DWF-5.4.

The manufacturer's description calls this gas compression non-lubricated and lists compressor, motor, coupling, flywheel, piping, cooling, electrical and auxiliary equipment. Cooling may be water, air or mixed; package forms include fixed, mobile, skid and acoustic enclosure by requirement. Define the actual gas-path lubrication boundary, package drawing and supplied auxiliaries. This wording does not make every bearing or drive mechanism lubricant-free.

A separate table row DW-4.9/(1.5-2.5)-22 lists 700 Nm³/h, 0.15–0.25 MPa inlet, 2.2 MPa discharge, 110 kW and 740 rpm, water cooling, 3800 × 2700 × 1800 mm and approximately 6000 kg. Another separate VWF-1.65/(25-35)-50 row gives 2500 Nm³/h, 2.5–3.5 MPa inlet, 5.0 MPa discharge, 90 kW and air cooling. These are family selection examples, not specifications of the pictured DWF header machine.

The page describes alarms/stops for low oil pressure, low water pressure, high temperature, low inlet pressure and high discharge pressure, with remote display/control by requirement. Obtain offered instruments, setpoints, interfaces and shutdown responsibility in the actual control schedule. Generic multi-industry application sentences do not establish food-contact, instrument-air or other gas suitability.

Provide composition, temperature, complete suction envelope, flow basis, required receiving pressure, liquid/contaminant conditions and duty cycle. Agree materials, sealing, purity/carryover, conditioning, vents and cooling utilities. Obtain offered performance, package input, P&ID, electrical/control and installation/foundation drawings, maintenance clearances, manuals and factory/acceptance tests. Specify commissioning, training, warranty scope and destination support. The complete original machine photograph is the manufacturer's non-standard natural-gas example, not every family configuration.

Catalog referenceLIANHE-NG
MachineProcess gas
PowerDWF-5.4:offered motor to confirm
Working pressureDWF-5.4:0.17–0.345 →2.1 MPa
Published flowDWF-5.4:5.4 m³/min;reference to agree
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantBengbu Lianhe Compressor
Named headerDWF-5.4/(1.7-3.45)-21
GasNatural gas
Header flow5.4 m³/min;reference basis not stated
Header pressure0.17–0.345 MPa inlet;2.1 MPa discharge
Named-header motor/envelopeObtain actual offered sheet;not inferred from another row
Gas-path descriptionNon-lubricated gas compression;drive/bearing lubrication boundary to agree
CoolingAir,water or mixed by requirement
Separate DW-4.9/(1.5-2.5)-22700 Nm³/h;0.15–0.25→2.2 MPa;110 kW;740 rpm;water-cooled
Separate DW installation3800 × 2700 × 1800 mm;approximately6000 kg
Separate VWF-1.65/(25-35)-502500 Nm³/h;2.5–3.5→5.0 MPa;90 kW;air-cooled
ProtectionOffered oil/water pressure,temperature and gas-pressure alarm/stop schedule

Plant

Bengbu Lianhe Compressor

Bengbu

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a Process gas duty

All spec pages
DutyWrite on the RFQ
Process gas compressor manufacturers in China Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused.

Same type

Related Process gas products

Compare the published product information for each manufacturer.

Full Process gas list
Catalog ref.TypePowerPressureFlowAir qualityPlant
JINXING-STORAGE Jinxing gas-storage and CNG compressor package enquiries JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries Process gas — — — — Jinxing RFQ
ENRIC-CNG Enric modular CNG compression and filling-station modules ENRIC-CNGEnric modular CNG compression and filling-station modules Process gas Selected driver and station duty Selected suction / delivery envelope 300–6,700 Nm³/h · compressor family range — Enric RFQ
JEREH-GAS Jereh natural-gas boosting compressor packages JEREH-GASJereh natural-gas boosting compressor packages Process gas Historic project example: 1,253 kW driver Project-specific suction and delivery pressure Gas throughput: define normal-volume basis — Jereh RFQ
LIBANG-N2 Boxed oil-free nitrogen reciprocating compressors LIBANG-N2Boxed oil-free nitrogen reciprocating compressors Process gas 4.0–5.5 kW, selected 20 Nm³/h models Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet 20 Nm³/h, selected models; confirm basis — Libang RFQ
HANGYANG-O2 Hangyang oxygen reciprocating compressor duty selections HANGYANG-O2Hangyang oxygen reciprocating compressor duty selections Process gas 850 / 110 kW, distinct oxygen duties 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute 10000 / 550 N in source flow column; confirm basis — Hangyang RFQ
JXG-D-HYDROGEN JY D-family hydrogen reciprocating compressor selections JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections Process gas Selected D rows: 132 / 355 / 280 kW Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa 5 / 10 / 22 m³/min, separate selected duties — Jiangxi Gas Compressor — JY Ganzhou RFQ

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

LIANHE-NG: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ