Vocke V11 single-stage semi-hermetic screw refrigeration series from Zhejiang Vocke Refrigeration (Jinhua)

Vocke classifies V11 as a single-stage screw refrigeration series. Its English product range identifies the screw compressors as semi-hermetic. The original V11–V14 series image is a family illustration; specify the full V11 model and current drawing for an order.

The catalogue pairs V11K84-30 with displacement of 84/101 m³/h at 50/60 Hz, maximum current 52 A, maximum power 33 kW and weight 170 kg. V11N84-20 shares the displacement entry but has 48 A maximum current, 29 kW maximum power and 166 kg weight. The notation chart identifies K as single-stage high-temperature and N as single-stage low-temperature. Keep these model-dependent ratings separate; maximum electrical power is not cooling output or electrical consumption at every duty point.

The shared electrical entry is three-phase 380–420 V at 50 Hz or 440–480 V at 60 Hz, with a delta/double-delta notation. Confirm the exact motor winding, terminal diagram, starting arrangement and allowable supply with the offered model. The V11 connection record lists 42 mm discharge and 54 mm suction. Request the current drawing, service-valve arrangement, mounting and piping interfaces.

The series describes motor protection, PTC discharge-temperature protection, an internal discharge check valve and provision for an external economizer. Economizer connection provision is not an included complete economizer package. Specify separator/oil management, injection arrangements, capacity control, protection module and auxiliaries with the compressor quotation.

For selection, provide refrigerant, required refrigeration load, evaporating/condensing temperatures, suction superheat, liquid subcooling and frequency. Obtain the exact cooling capacity and input at that point, the operating envelope and any economizer assumptions. Displacement in m³/h cannot replace a refrigeration-capacity selection in kW. Confirm refrigerant, oil and destination requirements together with installation, commissioning and replacement-part responsibilities.

Catalog referenceVOCKE-V11
MachineRefrigeration
Power—
Working pressure—
Published flow—
Air quality—
DutyCold chain
SupplyNot specified
PlantZhejiang Vocke Refrigeration (Jinhua)
ArchitectureSingle-stage semi-hermetic screw refrigeration
Named modelsV11K84-30 (K high-temperature); V11N84-20 (N low-temperature)
Displacement 50/60 Hz84/101 m³/h; not refrigeration capacity
V11K84-30Maximum current 52 A; maximum power 33 kW; 170 kg
V11N84-20Maximum current 48 A; maximum power 29 kW; 166 kg
Electrical reference380–420 V/3/50 Hz; 440–480 V/3/60 Hz
Connection recordDischarge 42 mm; suction 54 mm
Selection conditionsRefrigerant, evaporating/condensing temperature, superheat, subcooling, frequency
ScopeCurrent drawing, oil/protection/control and economizer auxiliaries to agree

Plant

Zhejiang Vocke Refrigeration (Jinhua)

Jinhua

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a Refrigeration duty

All spec pages
DutyWrite on the RFQ
Refrigeration screw compressor manufacturers in China A refrigeration screw compressor is selected for a refrigerant and operating conditions. Start with required cooling capacity, evaporating and condensing temperatures, electrical supply and the system arrangement. An air-compressor pressure rating or a motor nameplate alone cannot define this duty.

Same type

Related Refrigeration products

Compare the published product information for each manufacturer.

Full Refrigeration list
Catalog ref.TypePowerPressureFlowAir qualityPlant
BINGSHAN-REF-COMP Bingshan industrial refrigeration screw compressor enquiries BINGSHAN-REF-COMPBingshan industrial refrigeration screw compressor enquiries Refrigeration — — — — Bingshan Cold & Heat RFQ
BITZER-ECOLINE ECOLINE semi-hermetic piston refrigeration BITZER-ECOLINEECOLINE semi-hermetic piston refrigeration Refrigeration — — — — BITZER RFQ
MCQUAY-HSMcQuay semi-hermetic single-screw refrigeration selection Refrigeration Selected compressor input required Refrigerant operating envelope required Refrigeration duty; not air FAD — McQuay RFQ
WULENG-SCREW-REF Wuleng S-series screw refrigeration compressors WULENG-SCREW-REFWuleng S-series screw refrigeration compressors Refrigeration Select refrigerant and duty Refrigeration-duty selection 3512–9059 m³/h theoretical displacement — Wuhan New World RFQ
BINGSHAN-REF-PACKAGE Bingshan industrial refrigeration and LSVLGF glycol-system enquiries BINGSHAN-REF-PACKAGEBingshan industrial refrigeration and LSVLGF glycol-system enquiries Refrigeration — — — — Bingshan Cold & Heat RFQ
SONYO-REF Sonyo H-platform 50 HP refrigeration scroll SONYO-REFSonyo H-platform 50 HP refrigeration scroll Refrigeration 50 HP manufacturer class (not electrical input) Refrigerant pressure: confirm model envelope — — Bingshan Sonyo Compressor RFQ

VOCKE-V11: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.