Process gas
Wuleng single- and two-stage natural-gas compression skids — Wuhan New World Refrigeration (Bingshan group)
Wuleng single- and two-stage natural-gas compression skids · Wuhan New World Refrigeration (Bingshan group)
Datasheet
Product overview
Power: 55–2000 kW, model-dependent · Pressure: 2.0–4.2 MPa outlet envelope; basis to confirm · Flow: 227–12000 m³/h; reference to confirm
Wuleng describes split modular natural-gas compression skids for single- and two-stage duties. The modular arrangement supports transport and site layout; confirm the actual skid split, installation interfaces, dimensions and assembly responsibilities in the project drawings.
The manufacturer's published family envelope gives volumetric flow 227–12,000 m³/h, inlet pressure 0.05–2.0 MPa, outlet pressure 2.0–4.2 MPa and motor power 55–2,000 kW. The source does not define the flow reference conditions or identify the MPa values as gauge or absolute. Retain those original units and request definitions; do not convert the flow label to Nm³/h or combine envelope maxima into a made-up guaranteed duty.
The page describes 10–100% stepless flow regulation and optional internal volume-ratio adjustment of 2.5–5.0. Their applicability needs the selected compressor and actual gas conditions. Submit gas composition, temperature, suction-pressure variation, moisture/liquid content, corrosive constituents and required delivery pressure. Ask for the model's paired operating point and performance throughout the required load range.
Agree inlet/outlet separation, interstage or discharge cooling, gas/material compatibility, drains, instrumentation and shutdown functions, hazardous-area and destination requirements. Request total package power, utility duties, general-arrangement drawings, gas-tightness/performance-test conditions, startup procedures and commissioning/parts support. The original official photo shows the corresponding modular compression equipment, not an as-built package for the reader's gas stream.
| Catalog reference | WULENG-NG-SKID |
|---|---|
| Machine | Process gas |
| Power | 55–2000 kW, model-dependent |
| Working pressure | 2.0–4.2 MPa outlet envelope; basis to confirm |
| Published flow | 227–12000 m³/h; reference to confirm |
| Air quality | — |
| Duty | Energy / gas |
| Supply | Not specified |
| Plant | Wuhan New World Refrigeration (Bingshan group) |
| {"Published flow envelope" | "227–12000 m³/h; reference conditions not stated", "Inlet-pressure envelope": "0.05–2.0 MPa; gauge/absolute basis to confirm", "Outlet-pressure envelope": "2.0–4.2 MPa; gauge/absolute basis to confirm", "Motor range": "55–2000 kW; selected model required", "Flow regulation": "10–100%, manufacturer family description", "Optional internal volume ratio": "2.5–5.0 stepless adjustment"} |
Plant
Wuhan New World Refrigeration (Bingshan group)
Wuhan
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
- WULENG-SCREW-REF · Select refrigerant and duty
- WULENG-STEAM-SCREW · Selected heat/mass balance
Specification pages
Specifying a Process gas duty
| Duty | Write on the RFQ |
|---|---|
| Process gas compressor manufacturers in China | Process gas is not plant air. Molecular weight, suction pressure, discharge pressure and flow size the machine. A kW from an air catalogue is unused. |
Same type
Related Process gas products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
JINXING-STORAGEJinxing gas-storage and CNG compressor package enquiries
|
Process gas | — | — | — | — | Jinxing | RFQ |
ENRIC-CNGEnric modular CNG compression and filling-station modules
|
Process gas | Selected driver and station duty | Selected suction / delivery envelope | 300–6,700 Nm³/h · compressor family range | — | Enric | RFQ |
JEREH-GASJereh natural-gas boosting compressor packages
|
Process gas | Historic project example: 1,253 kW driver | Project-specific suction and delivery pressure | Gas throughput: define normal-volume basis | — | Jereh | RFQ |
LIBANG-N2Boxed oil-free nitrogen reciprocating compressors
|
Process gas | 4.0–5.5 kW, selected 20 Nm³/h models | Selected models: 0.6 MPa inlet; 2.5 / 3.0 / 4.0 MPa outlet | 20 Nm³/h, selected models; confirm basis | — | Libang | RFQ |
HANGYANG-O2Hangyang oxygen reciprocating compressor duty selections
|
Process gas | 850 / 110 kW, distinct oxygen duties | 1.156 → 4.998 or 0.103 → 3.04 MPa; inlet absolute | 10000 / 550 N in source flow column; confirm basis | — | Hangyang | RFQ |
JXG-D-HYDROGENJY D-family hydrogen reciprocating compressor selections
|
Process gas | Selected D rows: 132 / 355 / 280 kW | Selected inlet → outlet: 0.08 → 12; 2.40 → 3.60; 0.04 → 1.60 MPa | 5 / 10 / 22 m³/min, separate selected duties | — | Jiangxi Gas Compressor — JY Ganzhou | RFQ |
WULENG-NG-SKID: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.