Centrifugal

IHI-Sullair f engineered centrifugal air/nitrogen compression and boosting — IHI-Sullair Compression Technology (Suzhou)

IHI-Sullair f engineered centrifugal air/nitrogen compression and boosting · IHI-Sullair Compression Technology (Suzhou)

IHI-Sullair f engineered centrifugal air/nitrogen compression and boosting — official catalog illustration
Complete original f-series engineered-equipment photograph; exact skid, utilities and auxiliary scope are determined by the project.

Datasheet

Product overview

Power: f family:1000–20000 kW · Pressure: f family:1.5–65 barg · Flow: Engineered duty/reference conditions required

IHI-Sullair describes f as an engineered, user-customized centrifugal air/nitrogen compressor and booster family. Its official range is 1.5–65 barg and 1000–20000 kW. Those envelopes must not be combined into a single machine rating or treated as proof that any compressor can handle every pressure, gas composition or inlet condition. Obtain the named offered model and engineered duty.

The page describes inlet-guide-vane regulation, constant-pressure and load/unload control, oil-free compression and horizontally split construction for service access. These are design-family descriptions, not a numerical stable-flow/turndown curve or an independently verified purity certificate. Define the complete process envelope, protection and recycle/blow-off/control requirements in the actual proposal.

Separate an air compressor from a nitrogen booster: the latter receives already available nitrogen at specified composition, purity, pressure and temperature. It is not a nitrogen generator. Give normal/base/peak flow with reference conditions, suction-pressure and temperature extremes, contaminants/liquid risk, required delivery pressure and allowable carryover. Agree seals/materials, treatment and utility interfaces for the actual gas service; do not transfer an air-model performance rating to nitrogen unchanged.

The company profile names the separate manufacturing base 石川岛寿力回转科技制造(苏州)有限公司 in the Suzhou–Xiangcheng Cooperation Zone, completed in 2024 for large industrial f equipment. A dated local-government report records the 5 November 2024 inauguration. Agree the contracting, manufacturing, testing and service parties for this order; a new factory announcement is not an acceptance record for the offered machine.

Request same-duty capacity/package-input maps, cooling utilities, model-specific installation/foundation and nozzle loads, electrical/drive scope, control/interlock schedules, stable operating limits and lifting/removal access. Establish receiving/preservation, installation, alignment, commissioning and training responsibilities. Define the factory and site test plan, documentation, wear parts/spares, warranty commencement/exclusions and destination attendance. The complete official f-series photograph illustrates engineered equipment; actual skid arrangements and auxiliaries are project-specific.

Catalog referenceIHI-SULLAIR-F
MachineCentrifugal
Powerf family:1000–20000 kW
Working pressuref family:1.5–65 barg
Published flowEngineered duty/reference conditions required
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantIHI-Sullair Compression Technology (Suzhou)
ApplicationEngineered air/nitrogen compression and boosting
f pressure envelope1.5–65 barg;gauge pressure
f power envelope1000–20000 kW;series range
SelectionProject-specific offered model and process envelope
CapacityFlow and reference conditions required;no inferred rating
ControlIGV regulation;constant-pressure and load/unload
ConstructionHorizontally split maintenance design
Gas boundaryNitrogen boosting is not nitrogen generation
Manufacturing2024 separate Suzhou–Xiangcheng base named by company
InterfacesGas composition,inlet envelope,seals,cooling,drive,protection
TestsAgreed offered performance and factory/site acceptance

Plant

IHI-Sullair Compression Technology (Suzhou)

Suzhou

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a Centrifugal duty

All spec pages
DutyWrite on the RFQ
Compressor for wastewater treatment Most aeration trains want low-pressure blowers. If this RFQ is actually 7–8 bar plant air for valves and instruments, say so — it is a different machine from a maglev blower.
Centrifugal compressor manufacturers in China Centrifugal machines are duty-built. A 250 kW “centrifugal compressor China” RFQ without gas, suction and discharge pressure cannot be quoted.

Same type

Related Centrifugal products

Compare the published product information for each manufacturer.

Full Centrifugal list
Catalog ref.TypePowerPressureFlowAir qualityPlant
JTL-INDUSTRIAL-AIR JTL JE centrifugal air compressors and JED single-stage range JTL-INDUSTRIAL-AIRJTL JE centrifugal air compressors and JED single-stage range Centrifugal JE6000: 355–800 kW · configuration range JE: 2.2–10.5 barG · select operating point JE6000: 80–130 m³/min · reference basis to agree — Jintongling RFQ
HANWHA-CENTRI Hanwha SM / SM100 Pro centrifugal air compressor selections HANWHA-CENTRIHanwha SM / SM100 Pro centrifugal air compressor selections Centrifugal SM2100 150–335; SM3100 Pro 250–600 kW SM2100 5.0–11.4 bar(A); Pro duty to select SM2100 1400–3550; Pro 3300–5690 m³/h — Hanwha Power Shanghai — compressor sales and service RFQ
TLINGTE-TI Turbo-Tech Ti centrifugal air and nitrogen compressors TLINGTE-TITurbo-Tech Ti centrifugal air and nitrogen compressors Centrifugal Driver selected to duty 0.06–1.60 MPa(G), family envelope 1200–24000 Nm³/h, family envelope — Turbo-Tech RFQ
HYTP-ISOTHERMAL-AIR Hangyang single-shaft isothermal main-air compressors HYTP-ISOTHERMAL-AIRHangyang single-shaft isothermal main-air compressors Centrifugal Motor or steam turbine;duty-specific Selected main-air delivery duty ASU scale below40,000 Nm³/h;not air flow — Hangyang Turbine RFQ
IHI-SULLAIR-TX IHI-Sullair TX centrifugal air — 4–9 barg series selection IHI-SULLAIR-TXIHI-Sullair TX centrifugal air — 4–9 barg series selection Centrifugal TX series:150–425 kW TX series:4–9 barg Offered model flow/reference required — IHI-Sullair RFQ
SHAANGU-E Shaangu E horizontal-split process centrifugal compressors SHAANGU-EShaangu E horizontal-split process centrifugal compressors Centrifugal Selected train driver/input to agree Actual gas operating envelope required Project-specific flow/map and reference — Shaangu RFQ

IHI-SULLAIR-F: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ