Centrifugal

IHI-Sullair TRE/TRA centrifugal air — horizontally split service access — IHI-Sullair Compression Technology (Suzhou)

IHI-Sullair TRE/TRA centrifugal air — horizontally split service access · IHI-Sullair Compression Technology (Suzhou)

IHI-Sullair TRE/TRA centrifugal air — horizontally split service access — official catalog illustration
Complete official TRE/TRA-series equipment photograph; selected installation and supplied auxiliaries must be defined in the offer.

Datasheet

Product overview

Power: TRE/TRA:180–1250 kW · Pressure: TRE/TRA:2–16 barg · Flow: Offered model capacity/map required

The official TRE/TRA page lists a centrifugal compressor family at 2–16 barg and 180–1250 kW. The ranges describe series selection, not one model that operates at every pressure and power combination. Capacity, intake conditions and a named performance curve must come from the actual offered sheet; no air flow is invented from motor size.

The manufacturer describes titanium-alloy impellers, guide-vane regulation and constant-pressure plus load/unload controls. It also identifies an integrally cast body and horizontally split design for maintenance. Its broader maintenance description explains inspection of gears, rotors, seals and bearings after removing the gearbox upper cover, without removing unrelated air/water piping. Plan actual lifting/removal access and safe service responsibility using the offered machine's manual; this wording does not quantify a maintenance duration.

The compression is described as oil-free. Lubrication of the drive and bearing system is a separate boundary, and the installation library includes lubricant filling. Agree air-quality limits and drying/filtration at the point of delivery instead of assuming a current certification or ISO8573 class for every configuration.

For sustained industrial air duty, provide shift demand, base and peak flow, delivery pressure after losses, cooling-water/air conditions and available supply. Ask for same-condition flow and total input, usable regulation and stable operating limits, network sequencing, abnormal-condition alarms/shutdowns and bypass/blow-off operation. Constant-pressure wording does not remove the need for an actual control and performance map.

Obtain footprint, mass, foundation and nozzle-load data, utility/electrical schedules and inspection/removal space. Define installation, alignment, preservation removal, commissioning, manuals/spares and tests linked to the delivered model. Agree factory performance and site acceptance with warranty/exclusions and destination-support terms. The complete original TRE/TRA photo is family equipment, not proof of the selected duty or supplied auxiliaries.

Catalog referenceIHI-SULLAIR-TRE
MachineCentrifugal
PowerTRE/TRA:180–1250 kW
Working pressureTRE/TRA:2–16 barg
Published flowOffered model capacity/map required
Air quality—
DutyEnergy / gas
SupplyNot specified
PlantIHI-Sullair Compression Technology (Suzhou)
MechanismCentrifugal air compressor
TRE/TRA pressure envelope2–16 barg;gauge pressure
TRE/TRA power envelope180–1250 kW;series range
CapacityActual offered model map required
Impeller descriptionTitanium alloy
ConstructionIntegrally cast body;horizontally split design
ControlInlet guide vane;constant-pressure and load/unload
MaintenanceActual cover/component removal and lifting access
Oil-free boundaryGas-path description;drive/bearing lubrication separate
InstallationFoundation,piping,electrical,alignment and model instructions
AcceptanceSame-condition capacity/input,outlet quality and protections

Plant

IHI-Sullair Compression Technology (Suzhou)

Suzhou

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a Centrifugal duty

All spec pages
DutyWrite on the RFQ
Centrifugal compressor manufacturers in China Centrifugal machines are duty-built. A 250 kW “centrifugal compressor China” RFQ without gas, suction and discharge pressure cannot be quoted.
Compressor for wastewater treatment Most aeration trains want low-pressure blowers. If this RFQ is actually 7–8 bar plant air for valves and instruments, say so — it is a different machine from a maglev blower.

Same type

Related Centrifugal products

Compare the published product information for each manufacturer.

Full Centrifugal list
Catalog ref.TypePowerPressureFlowAir qualityPlant
JTL-INDUSTRIAL-AIR JTL JE centrifugal air compressors and JED single-stage range JTL-INDUSTRIAL-AIRJTL JE centrifugal air compressors and JED single-stage range Centrifugal JE6000: 355–800 kW · configuration range JE: 2.2–10.5 barG · select operating point JE6000: 80–130 m³/min · reference basis to agree — Jintongling RFQ
HANWHA-CENTRI Hanwha SM / SM100 Pro centrifugal air compressor selections HANWHA-CENTRIHanwha SM / SM100 Pro centrifugal air compressor selections Centrifugal SM2100 150–335; SM3100 Pro 250–600 kW SM2100 5.0–11.4 bar(A); Pro duty to select SM2100 1400–3550; Pro 3300–5690 m³/h — Hanwha Power Shanghai — compressor sales and service RFQ
TLINGTE-TI Turbo-Tech Ti centrifugal air and nitrogen compressors TLINGTE-TITurbo-Tech Ti centrifugal air and nitrogen compressors Centrifugal Driver selected to duty 0.06–1.60 MPa(G), family envelope 1200–24000 Nm³/h, family envelope — Turbo-Tech RFQ
HYTP-ISOTHERMAL-AIR Hangyang single-shaft isothermal main-air compressors HYTP-ISOTHERMAL-AIRHangyang single-shaft isothermal main-air compressors Centrifugal Motor or steam turbine;duty-specific Selected main-air delivery duty ASU scale below40,000 Nm³/h;not air flow — Hangyang Turbine RFQ
IHI-SULLAIR-TX IHI-Sullair TX centrifugal air — 4–9 barg series selection IHI-SULLAIR-TXIHI-Sullair TX centrifugal air — 4–9 barg series selection Centrifugal TX series:150–425 kW TX series:4–9 barg Offered model flow/reference required — IHI-Sullair RFQ
SHAANGU-E Shaangu E horizontal-split process centrifugal compressors SHAANGU-EShaangu E horizontal-split process centrifugal compressors Centrifugal Selected train driver/input to agree Actual gas operating envelope required Project-specific flow/map and reference — Shaangu RFQ

IHI-SULLAIR-TRE: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ