Centrifugal
McQuay centrifugal refrigeration — WTCV3000 launch and selection — McQuay Air Conditioning & Refrigeration (Suzhou)
McQuay centrifugal refrigeration — WTCV3000 launch and selection · McQuay Air Conditioning & Refrigeration (Suzhou)
McQuay centrifugal refrigeration — WTCV3000 launch and selection
Datasheet
Product overview
Power: Launch drive: 10 kV; input map required · Pressure: Selected refrigerant/temperature envelope · Flow: WTCV3000: up to 3500 RT launch claim
McQuay's Suzhou centrifugal refrigeration range includes distinct single/two-stage, magnetic-bearing, direct-drive and multi-stage designs. A government report dated 9 September 2026 and the official announcement published 30 September identify the WTCV3000 compressor launch at the Suzhou works on 7 September. They describe 10 kV high-speed direct impeller drive and a maximum cooling-duty claim of 3500 RT.
That launch maximum is not motor output, package input, air flow or a selected operating point. The announcement does not provide a full refrigerant/temperature performance map, exact absorbed power or complete order configuration. Confirm availability, refrigerant, rated conditions, electrical/drive boundary, auxiliaries and actual origin in the quotation.
The separate WTCV complete-chiller page lists a family cooling range of 1760–3306 kW with R134a and two-stage direct-drive construction. Its system illustration and ratings must not be called a WTCV3000 compressor datasheet. Oil-bearing and magnetic-bearing arrangements also require separate selection; the plant portfolio does not make every centrifugal model oil-free.
Provide cooling/heating duty, water temperatures/flows, condenser or source conditions, seasonal load profile, ambient and supply characteristics. Obtain compressor/system maps, minimum stable load, surge-control and restart limits, actual part-load input and pump/auxiliary boundaries. Agree test and rating methods, lubrication or bearing-service requirements, refrigerant management, commissioning and destination maintenance/spares. The factory's stated 1700 RT test-platform range is a test-capability description, not proof of a 3500 RT test or a product ceiling. No ceremony photograph is presented as the selected machine.
| Catalog reference | MCQUAY-CENTRIF |
|---|---|
| Machine | Centrifugal |
| Power | Launch drive: 10 kV; input map required |
| Working pressure | Selected refrigerant/temperature envelope |
| Published flow | WTCV3000: up to 3500 RT launch claim |
| Air quality | — |
| Duty | Cold chain |
| Supply | Not specified |
| Plant | McQuay Air Conditioning & Refrigeration (Suzhou) |
| Dated launch | WTCV3000 at Suzhou; 7 September 2026 |
| Published launch drive | 10 kV high-speed direct impeller drive |
| Published maximum | 3500 RT cooling claim; rating point requires selected map |
| Do not substitute | Cooling duty for motor/input power or air flow |
| Separate WTCV chiller family | 1760–3306 kW cooling; R134a |
| Construction boundary | Oil-bearing/direct-drive and magnetic-bearing variants differ |
| Testing boundary | 1700 RT bench description is not the 3500 RT acceptance result |
| Quotation | Actual refrigerant,map,input,control envelope and auxiliary scope |
Plant
McQuay Air Conditioning & Refrigeration (Suzhou)
Suzhou
The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.
- MCQUAY-HS · Selected compressor input required
- MCQUAY-HSO · Actual driver and absorbed input required
Specification pages
Specifying a Centrifugal duty
| Duty | Write on the RFQ |
|---|---|
| Compressor for wastewater treatment | Most aeration trains want low-pressure blowers. If this RFQ is actually 7–8 bar plant air for valves and instruments, say so — it is a different machine from a maglev blower. |
| Centrifugal compressor manufacturers in China | Centrifugal machines are duty-built. A 250 kW “centrifugal compressor China” RFQ without gas, suction and discharge pressure cannot be quoted. |
Same type
Related Centrifugal products
Compare the published product information for each manufacturer.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
JTL-INDUSTRIAL-AIRJTL JE centrifugal air compressors and JED single-stage range
|
Centrifugal | JE6000: 355–800 kW · configuration range | JE: 2.2–10.5 barG · select operating point | JE6000: 80–130 m³/min · reference basis to agree | — | Jintongling | RFQ |
HANWHA-CENTRIHanwha SM / SM100 Pro centrifugal air compressor selections
|
Centrifugal | SM2100 150–335; SM3100 Pro 250–600 kW | SM2100 5.0–11.4 bar(A); Pro duty to select | SM2100 1400–3550; Pro 3300–5690 m³/h | — | Hanwha Power Shanghai — compressor sales and service | RFQ |
TLINGTE-TITurbo-Tech Ti centrifugal air and nitrogen compressors
|
Centrifugal | Driver selected to duty | 0.06–1.60 MPa(G), family envelope | 1200–24000 Nm³/h, family envelope | — | Turbo-Tech | RFQ |
HYTP-ISOTHERMAL-AIRHangyang single-shaft isothermal main-air compressors
|
Centrifugal | Motor or steam turbine;duty-specific | Selected main-air delivery duty | ASU scale below40,000 Nm³/h;not air flow | — | Hangyang Turbine | RFQ |
IHI-SULLAIR-TXIHI-Sullair TX centrifugal air — 4–9 barg series selection
|
Centrifugal | TX series:150–425 kW | TX series:4–9 barg | Offered model flow/reference required | — | IHI-Sullair | RFQ |
SHAANGU-EShaangu E horizontal-split process centrifugal compressors
|
Centrifugal | Selected train driver/input to agree | Actual gas operating envelope required | Project-specific flow/map and reference | — | Shaangu | RFQ |
MCQUAY-CENTRIF: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.
Issue RFQ