PET / HP

KSP-OF screw-and-piston PET air packages — ADEKOM

KSP-OF screw-and-piston PET air packages · ADEKOM

KSP-OF screw-and-piston PET air packages — official catalog illustration
KSP-OF screw-and-piston PET air packages — manufacturer catalog illustration

Datasheet

Product overview

Power: 67 kW installed · KSP-OF6/40PM · Pressure: 40 barg · KSP-OF6/40PM · Flow: 6.0 Nm³/min · normal-volume capacity

ADEKOM’s KSP-OF package uses a water-lubricated screw stage and an oil-free piston booster for PET bottle-blowing air. The KSP-OF6/40PM reference is listed at 6.0 Nm³/min and 40 barg, with 67 kW installed power. The OF8 counterpart has 8.0 Nm³/min capacity, 85 kW installed power and the same listed working pressure. Keep the OF suffix: the separately listed KSP-II family has different installed powers and weights.

Capacity is expressed as normal volume. Match the bottle-blowing machine’s consumption to the agreed normal reference temperature and pressure; this value should not be relabelled as FAD or treated as actual volume inside a 40 barg line. Send peak and average demand, blow-cycle timing, required pressure at the machine and available receiver capacity. Ask how the proposed compressor, storage and pressure control meet successive cycles.

For OF6, the manufacturer lists 20 t/h cooling-water flow, a 3000 × 1550 × 1650 mm outline in L × W × H order and a 2800 kg package weight. OF8 needs 24 t/h and weighs 3100 kg. Establish inlet-water temperature, pressure, quality, heat rejection and cooler maintenance; a water-flow figure alone is not a complete utility design.

Itemise the high-pressure receiver, dryer, filtration, drains, safety equipment, controls and connecting pipework. Agree air-quality requirements at the blow-moulder and obtain relevant model-specific evidence. The official illustration shows the KSP family; the delivered model and its interfaces need their own approved drawing. Compare installed and measured package input on a consistent basis, and define factory testing, commissioning and routine spare parts in the offer.

Catalog referenceADEKOM-KSP
MachinePET / HP
Power67 kW installed · KSP-OF6/40PM
Working pressure40 barg · KSP-OF6/40PM
Published flow6.0 Nm³/min · normal-volume capacity
Air quality—
DutyPET / blowing
SupplyNot specified
PlantADEKOM
Reference modelKSP-OF6/40PM
ArrangementWater-lubricated screw plus oil-free piston booster
Air capacity6.0 Nm³/min at 40 barg
Installed power67 kW
Cooling-water flow20 t/h
Outline3000 × 1550 × 1650 mm (L × W × H)
Package weight2800 kg
KSP-OF8/40PM comparison8.0 Nm³/min at 40 barg; 85 kW; 24 t/h cooling water; 3100 kg
Capacity definitionConfirm normal reference temperature and pressure
Variant boundaryKSP-II installed power and weight are separate
Image scopeOriginal manufacturer family illustration

Plant

ADEKOM

Dongguan

The plant remains the seller. This desk issues the English duty sheet so quotes are comparable across clusters.

Specification pages

Specifying a PET / HP duty

All spec pages
DutyWrite on the RFQ
Compressor for PET bottle blowing Bottle blowing is a high-pressure oil-free process. The blower OEM’s pressure and the cavity count size the compressor, not the word PET.
30 bar oil-free compressor Specify whether 30 bar is gauge or absolute pressure, where it is required and how much air must be supplied at that point. A 30 bar working duty does not, by itself, identify a compressor architecture, motor size or air-quality class.
40 bar PET compressor PET blowing at 40 bar(g) is a high-pressure oil-free duty. Cavities, bottle volume and recovery pressure size the skid — not the word “PET compressor”.

Same type

Related PET / HP products

Compare the published product information for each manufacturer.

Full PET / HP list
Catalog ref.TypePowerPressureFlowAir qualityPlant
UNIGY-PET-OILFREE UNIGY oil-free reciprocating PET air and booster packages UNIGY-PET-OILFREEUNIGY oil-free reciprocating PET air and booster packages PET / HP Exact selected motor / package input 0.7–5.0 MPa — published envelope 0.1–20 m³/min — reference required — UNIGY — Luoyang industrial gas compressors RFQ
DMG-DOLPHIN DMG Dolphin water-lubricated screw / piston PET systems DMG-DOLPHINDMG Dolphin water-lubricated screw / piston PET systems PET / HP OGV-6:67 kW installed /60 kW shaft Selected table duties:4.0 MPa OGV-6:6.0 Nm³/min; normal reference to agree — DMG RFQ
ZDHS-G0-G2 Zhongding G0–G2 diaphragm compressors for compact and process-gas duties ZDHS-G0-G2Zhongding G0–G2 diaphragm compressors for compact and process-gas duties PET / HP — — — — Zhongding RFQ
BAODE-LASERB&D BD-TK laser-cutting air packages, pressure-specific variants PET / HP 15 / 22 kW · selected detail rows 1.5 / 2.5 / 3 MPa · selected variant BD-PM22TK: 0.88–2.2 m³/min · 1.5 MPa version — B&D RFQ
CMN-CMGPV CMN CM/GPV medium-pressure oil-free screw — dual-drive configurations CMN-CMGPVCMN CM/GPV medium-pressure oil-free screw — dual-drive configurations PET / HP Dual drives — preserve separate motor cells Configuration bands2.0–3.0 or2.0–4.0 MPa CM130GPV:5.4–13.5 or4.0–10.2 m³/min;bands differ — CMN RFQ
DMG-EAGLE DMG Eagle four-stage screw / piston PET systems DMG-EAGLEDMG Eagle four-stage screw / piston PET systems PET / HP 16 Nm³/min models:145 installed /131 shaft kW Selected table duties:4.0 MPa LGV2/LGW2 points:6–30 Nm³/min — DMG RFQ

Product information

Information reviewed 2026-10-08. Specifications apply only to the models and conditions stated.

ADEKOM-KSP: Voltage and frequency matter as much as bar. State both. Include the required operating conditions with your enquiry.

Issue RFQ