Catalog · 273 machines
Machines on the desk
Engineers compare kW, bar and FAD — not storefront tiles. Empty cells stay confirm-on-RFQ. We do not invent a SKU to look complete.
| Catalog ref. | Type | Power | Pressure | Flow | Air quality | Plant | |
|---|---|---|---|---|---|---|---|
OSG-EXOSG EX fixed-speed direct-drive screw — cooling and air-quality scope
|
Rotary screw | Selected EX-22A:22 kW;EX-75A/W:75 kW | EX-22A points:0.7 /0.8 /1.0 /1.3 MPa | EX-22A:3.5 m³/min at0.8 MPa | — | OSG | RFQ |
NJSF-MShunfeng M-type balanced reciprocating process-gas compressor
|
Process gas | — | — | — | — | Shunfeng | RFQ |
DONGYUE-LGFDDongyue LGFD-10/8Ⅱ-BP two-stage variable-speed screw reference
|
Rotary screw | — | — | — | — | Dongyue | RFQ |
AIPU-BOGAipu BOG-to-pipeline recovery — LNG boil-off gas duties
|
Process gas | Selected ZW rows:30 /37 kW | Selected ZW:0.5 MPa discharge;inlet varies | Selected ZW rows:650 /800 /850 Nm³/h | — | Aipu | RFQ |
LIANHE-NGLianhe DWF natural-gas transfer — named duty and package scope
|
Process gas | DWF-5.4:offered motor to confirm | DWF-5.4:0.17–0.345 →2.1 MPa | DWF-5.4:5.4 m³/min;reference to agree | — | Lianhe | RFQ |
JIANGBEI-CHEMJiangbei chemical and special-gas compressors — medium-specific selection
|
Process gas | Selected gas rows:11 /15 /45 kW | Medium-specific inlet and discharge MPa | Selected separate rows:150 /420 /270 Nm³/h | — | Jiangbei | RFQ |
IOT-NH3IOT ZW-0.8/16-24 ammonia compressor — vapour and unloading duty
|
Refrigeration | 15 kW motor | 1.6→2.4 MPa;basis to agree | 0.8 m³/min nominal;not normal-flow conversion | — | IOT Compressor | RFQ |
TONGDA-L-CNGL-type CNG standard-station compressors
|
Process gas | Selected L rows: 110 /132 kW | Named inlet rows→25 MPa family delivery | Selected duties: 540 /800 /700 /1500 Nm³/h | — | Tongda | RFQ |
HYTP-O2Hangyang single-shaft centrifugal oxygen compressors
|
Centrifugal | Selected oxygen duty and drive | Family below1.0 /4.0 MPa;confirm basis | Model selection by calculation;not axis ticks | — | Hangyang Turbine | RFQ |
SASPG-CNGSASPG reciprocating CNG station compressors
|
Process gas | CNG model and inlet-envelope curve | Actual station suction and delivery duty | Capacity curve across source pressure | — | SASPG | RFQ |
VOCKE-V21Vocke V21 single-stage semi-hermetic screw refrigeration series
|
Refrigeration | — | — | — | — | Vocke | RFQ |
HAIGAIR-PM-VSDHPV-15A single-stage PM VSD screw compressor
|
Rotary screw | HPV-15A:11 kW | Listed0.8 MPa;other options separate | Listed1.72 m³/min;test basis to agree | — | Haigair | RFQ |
HTXD-LASERHuitong Xinda laser-cutting screw — HD pressure and treatment interface
|
PET / HP | HD model rows:11/15/22 kW | 1.3 or 1.6 MPa by model | HD-11:1.4 or 1.2 m³/min respectively | — | Huitong Xinda | RFQ |
IHI-SULLAIR-TREIHI-Sullair TRE/TRA centrifugal air — horizontally split service access
|
Centrifugal | TRE/TRA:180–1250 kW | TRE/TRA:2–16 barg | Offered model capacity/map required | — | IHI-Sullair | RFQ |
SHENJIANG-PORTABLEShenjiang V0.67-8 wheeled piston compressor — duty and handling scope
|
Portable diesel | V0.67-8 offered motor to confirm | Signed pressure/receiver sheet required | No model-code inference;request rated flow | — | Shenjiang | RFQ |
HENGDA-AIRHengda industrial high-pressure and screw/booster air-system references
|
Rotary screw | — | — | — | — | Hengda | RFQ |
SAYI-B-SCREWSAYI BMF screw — published PM control and rating clarifications
|
Rotary screw | — | Selected table rows:8 bar | Selected confirmed rows:1.05–9 m³/min | — | SAYI | RFQ |
SHAANGU-EIZShaangu EIZ/EIZT internally cooled centrifugal air-separation trains
|
Centrifugal | Offered train driver/input required | ASU air-duty envelope to agree | ASU oxygen output is not compressor flow | — | Shaangu | RFQ |
FKW-DIAPHRAGMFKW diaphragm compressors for purity-sensitive gas duties
|
High-pressure diaphragm | Selected-model input and motor required | Actual gas and pressure-cycle selection | Matched inlet-case capacity required | — | Jinkaiwei | RFQ |
ZDHS-G3-G4Zhongding G3–G4 diaphragm compressors with named gas-duty references
|
PET / HP | — | — | — | — | Zhongding | RFQ |
QS-2D80-H2Qiangsheng 2D80-25/168-202 recycle-hydrogen compressor
|
Process gas | Actual recycle-duty driver required | 16.8 → 20.2 MPaG example | 25 m³/min at inlet conditions | — | Qiangsheng | RFQ |
| YUANDA-DD-type process reciprocating | Process gas | — | — | — | — | Yuanda | RFQ |
AI-OILFREE-PISTONANEST IWATA TFPJ tank-mounted oil-free reciprocating compressors
|
Piston | — | — | — | — | ANEST IWATA | RFQ |
KFAS-HKFAS H twin-shaft centrifugal air and nitrogen duty references
|
Centrifugal | 625 kW shaft power, reference air duty | 0.098 to 0.70 MPa absolute, air duty | 125 m³/min, reference air duty | — | KFAS | RFQ |
Not on the row: If the nameplate you need is not listed, send the duty. We route it to plants that can hold the pressure.
Open RFQ